GD Midea Refrigeration Equipment Elite Series Technical & Service Manual page 27

R22 wall mounted split type, heat pump air conditioner
Table of Contents

Advertisement

8.8.1.3 During the start-up and operation, all of the following protecting functions work:
3minutes start-up delay protection, overload protection, outdoor protection, evaporator
Protection against low temperature. If any of the protection functions, the comparative protecting
action is executed.
The forced cooling mode is closed by one touch on the button, meanwhile the operation light is off,
the buzzer buzzes lasts for 1 seconds, then A/C turns to be closedown status.
8.8.2.
Forced Auto
8.8.2.1 Remote control signal can be received in forced auto mode. When receiving the signals, the
forced auto mode will be canceled and the A/C changes to remote control status and performs
operation as the signals indicates.
8.8.2.2 The system performs control according to the remote control auto mode with a set temperature of
24°c.
8.9
Timer
24 hours timer on or off.
8.10
Protecting Function
8.10.1
Compress with a delay of 3 minutes.
8.10.2
Sensor open and break protection
8.10.3
EEPROM error protection.
8.10.4
Current protection function.
Current up
Current
down
8.11 Auto restart Function
In case of a sudden power failure, this function automatically sets the unit to previous
settings before the power failure when power returns.
Condition
Indoor fan
I< I
RESTORE
I
<I< I
RESTORE
FAN
I
<I<I
FAN
5MIN
I
<I< I
5MIN
3SEC
I
<I< I
5MIN
3SEC
I
<I<I
FAN
5MIN
I
<I< I
RESTORE
FAN
I< I
RESTORE
Compressor
On
On
On
On
Low speed
On
Off
Off
Off
Off
On
On
Low speed
On
On
On
26
Outdoor fan
Remark
On
Off
Heating mode
On
Cooling mode
Off
After 5 Minutes
Off
After 3 Seconds
Off
After 3 Seconds
Off
After 5 Minutes
Off
Heating mode
On
Cooling mode
On