AMEREC STEAMBATH GENERATOR
(MODEL: AV2, 2KW/120 VOLT)
SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
POST "WARNING" LABEL OUTSIDE STEAMBATH FOR SAFETY
WARNINGS. REQUIRED POSTING ON DOOR OF STEAM ROOM
OR ADJACENT TO DOOR FOR ALL COMMERCIAL
INSTALLATIONS.

SECTION 1: GENERAL INFORMATION

AMEREC steam generators are listed by Underwriters Laboratories. The steam generators come assembled
and ready for installation. Check that the size and rating of the generator is suitable for your application.
IMPORTANT
An exhaust fan installed outside the steam
room is strongly recommended to remove
excess steam from the bathroom or shower
area.
4211-123 10-15-08
AV Series Installation and Service Instructions
WARNING
Electrical grounding is required on
all AMEREC steambath generators.
All electrical supplies should be
disconnected when servicing
generator.
All wiring must be installed by a
licensed electrical contractor in
accordance with local and national
codes.
All plumbing must be installed by a
licensed plumber in accordance with
all applicable local and national
codes.
AV series generators are for indoor
use only.
AV series generators are not for
space heating purposes.
Be certain that steambath
enclosures are properly sealed to
avoid water damage from escaping
steam. It is recommended that 100%
silicone caulk be used to seal all
pipes and fittings. Steam must be
prevented from escaping into the
wall cavity.
Never shut off the water to a steam
generator that is in use.
For Residential use only in Acrylic or
Fiberglass Enclosures rated for
Steam.
WARNING
REDUCE THE RISK OF
OVERHEATING AND SCALDING
1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in
a heated area is capable of causing overheating.
2. Supervise children at all times.
3. Check with a doctor before use if pregnant, diabetic, in poor health or
under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs
or medication is capable of causing unconsciousness.
FORFor
Do not contact steam head. Stay at least 12" away
CAUTION!
from hot steam escaping from the steam outlet.
REDUCE THE RISK OF
SLIPPING AND FALL INJURY
Use care when entering or exiting the steam room, floor may be slippery.
NOTE: For additional safety instructions, see owner's manual.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AV Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amerec AV Series

  • Page 1: Section 1: General Information

    REDUCE THE RISK OF AMEREC steam generators are listed by Underwriters Laboratories. The steam generators come assembled SLIPPING AND FALL INJURY and ready for installation. Check that the size and rating of the generator is suitable for your application.
  • Page 2: Important Safety Instructions

    AV Series Installation and Service Instructions page 2 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS 2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
  • Page 3: Section 2: Select Mounting Location

    AV Series Installation and Service Instructions page 3 DIAGRAM 1 WARNING Do not mount outdoors. Protect from freezing. Unit must be located as to allow access for service. The generator will not operate properly, unless it is mounted level with the arrows pointed up.
  • Page 4: Specifications

    AV Series Installation and Service Instructions page 4 DIAGRAM 2 DIAGRAM 3 LEAVE 1-1/2" GAP FROM 1/2" NPT MALE END OF 1/2" THREADED FITTING NPT FITTING 2 " TO FINISHED DIAM- INSIDE ETER 1/2" NPT SURFACE OF HOLE SWEAT SHOWER...
  • Page 5: Section 5: Plumbing Instructions

    AV Series Installation and Service Instructions page 5 SECTION 5: PLUMBING INSTRUCTIONS WARNING IMPORTANT Maximum recommend input water pressure not to Do not connect the overpressure exceed 100 PSI device output into the steam line. Plumbing Instructions and Cautionary Notes on Installation...
  • Page 6: Section 7: Control Installation

    AV Series Installation and Service Instructions page 6 SECTION 7: CONTROL INSTALLATION THIS LOW VOLTAGE CONTROL CAN BE LOCATED INSIDE OR OUTSIDE 1. Control cable rough-in: A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL. THE STEAM ENCLOSURE The low voltage control can be mounted up to 75 feet from the generator either inside or outside the steam room.
  • Page 7: Section 8: Service

    Description of SteamPro Steam Generator The AV series generator is the latest in modern steam generator design. The AV steam generator uses a printed circuit assembly to monitor and control all the equipment needed to produce steam. The system has three functions: a timer that controls the length of the steam bath; the operating water level is monitored and controlled;...
  • Page 8 AV Series Installation and Service Instructions page 8 SECTION 8: SERVICE (continued) C. WATER SOLENOID REPLACEMENT: Disconnect power from the unit. Turn the water supply OFF. Disconnect the water supply from the water solenoid valve. Remove the front cover. Remove the two black wires from the water solenoid valve.
  • Page 9 AV Series Installation and Service Instructions page 9 SECTION 9: SERVICE There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800-331-0349. The Trouble Shooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved.
  • Page 10: Section 10: Troubleshooting

    AV Series Installation and Service Instructions page 10 SECTION 10: TROUBLESHOOTING o r t " l . " l l i f . y l e r i e t i e r i o r t i l l i t a .
  • Page 11: Section 10: Wiring Diagram

    AV Series Installation and Service Instructions page 11 SECTION 10: WIRING DIAGRAM GREEN BLUE WHITE WATER VALVE GROUND AT TOP TANK MOUNTING TAB HIGH PROBE PROBE NEUTRAL POWER IN 120VAC GROUND ELEMENT 4124-14 01/09/02 F1 1/16 A SLO-BLO 4211-123 10-15-08...

This manual is also suitable for:

Av2

Table of Contents