Kenwood TK-3217 Service Manual page 22

Uhf fm transceiver
Hide thumbs Also See for TK-3217:
Table of Contents

Advertisement

TK-3217
Item
Condition
8.DQT
TEST CH: Center
Balance Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
9.Max deviation TEST CH: Center
Adjust
[Wide]
AG:1kHz/110mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
10.QT Deviation TEST CH: Center
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
11.DQT Deviation TEST CH: Center
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
12.DTMF Deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
13.MSK Deviation TEST CH: Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
22
ADJUSTMENT /
Test equipment
Power meter
Low
Deviation meter
High
Oscilloscope
(3 points)
AG
AF VTVM
Low
High
(3 points)
Low
High
(3 points)
Low
High
(3 points)
调整
Measurement
Terminal
ANT
Programming
Software:
KPG-100D(C)
ANT
Programming
SP/MIC connector
Software:
KPG-100D(C)
ANT
Programming
Software:
KPG-100D(C)
Adjustment
Parts
Method
Make the
demodulation
wave into
square waves
4.2kHz
(According to
the larger +,–)
2.2kHz
(According to
the larger +,–)
0.80kHz
0.42kHz
0.75kHz
0.38kHz
3.0kHz
1.5kHz
3.1kHz
1.5kHz
Specifications/
Remarks
±80Hz
±80Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3217 cTk-3217 c2

Table of Contents