Kenwood TK-2317 M3 Service Manual page 30

Vhf fm transceiver
Table of Contents

Advertisement

TK-2317
Frequency and Signaling
The transceiver has been adjusted for the frequencies
shown in the following table. When required, re-adjust them
following the adjustment procedure to obtain the frequencies
you want in actual operation.
■ Frequency (MHz)
Channel No.
RX Frequency
1
220.05000
2
216.05000
3
222.95000
4
220.00000
5
220.00000
6
220.40000
7~16
■ Signaling
Signaling No.
RX (Decode)
1
None
2
None
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 210.7Hz
6
QT 254.1Hz
7
DQT D023N
8
DQT D754I
9
DTMF (Code: 159D)
10
None
11
None
12
FleetSync (100~1000)
13
None
2-tone (A: 304.7Hz,
14
B: 3106.0Hz)
15
None
16
Single Tone (979.9Hz)
17
None
18
None
30
ADJUSTMENT
TX Frequency
220.10000
216.10000
222.90000
220.00000
220.20000
220.40000
-
-
TX (Encode)
None
100Hz Square Wave
QT 67.0Hz
QT 151.4Hz
QT 210.7Hz
QT 254.1Hz
DQT D023N
DQT D754I
DTMF (Code: 159D)
DTMF (Code: 9)
MSK (1010)
FleetSync (100~1000)
Single Tone (1000Hz)
2-tone (A: 304.7Hz,
B: 3106.0Hz)
DTMF Tone (1477Hz)
Single Tone (979.9Hz)
MSK PN9
DTMF (Code: 3)
Preparations for Tuning the Transceiver
Before attempting to tune the transceiver, connect the
unit to a suitable power supply.
Whenever the transmitter is tuned, the unit must be con-
nected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
8 dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
■ Adjustment frequency (MHz)
TEST CH
Low
216.05000
Low'
218.05000
Center
220.05000
High'
221.05000
High
222.95000
Adjustment Points
TX-RX UNIT
Component side view
B
CVIN
Note: "CVIN" VCO Lock voltage.
RX
TX
216.10000
218.10000
220.10000
221.10000
222.90000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3317Tk-3317 m3Tk-3317 m4

Table of Contents