Power Connection - GO Networks MBW 510 Installation Manual

Table of Contents

Advertisement

Power Connection

The MBW 510 unit can be connected to an AC power source by one of
several methods. It can be connected directly to a power source or by
using an adapter to connect to the streetlight photocell (photo-control).
The MBW 510 unit can support input voltage of 100 to 240 VAC (50 to 60
Hz).
Note:
Connect the grounding cable before connecting any other cables.
When removing the MBW 510, the grounding cable should be the
last cable removed.
Noter: Connecter la prise de terre 10 AWG avant de connecter tout autre
câble. Pendant la désinstallation du MBW 510, la prise de terre doit
être le dernier câble retiré.
To connect the AC power to the MBW 510 via the streetlight
photocell:
1. Check the input voltage to the streetlight photocell. The voltage
must be between 100 to 240 VAC. If yes, continue with this
procedure. Otherwise, use a different method for the power
connection.
2. Remove the streetlight photocell. Turn the photocell
counterclockwise and lift the photocell out of the socket.
3. Insert the Auxiliary Power Adapter in the socket of the photocell.
Note that one prong is larger than the other two. Align the larger
prong on the adapter with the larger slot in the socket. Insert the
Auxiliary Power Adapter into the socket and rotate the adapter
clockwise.
4. Insert the photocell into the Auxiliary Power Adapter. Align the
larger prong on the photocell with the larger slot in the socket on
top of the adapter. Insert the photocell into the socket and rotate
the photocell clockwise.
5. Connect the Auxiliary Power Adapter cable to the power connector
socket on the MBW 510.
6. After connecting the power, verify that the Power (PWR) LED is lit.
7. Check the photocell. Cover the photocell and verify that the
streetlight operates.
All contents are Copyright © 2007 GO Networks, Inc. All rights reserved.