FloTech FT151 Instruction Manual

Thermo-optic sensors and thermistor dummy

Advertisement

Available languages

Available languages

Quick Links

PRODUCT DESCRIPTIONS:
These instructions cover the following FloTech products:
FT150
Replacement Thermo-Optic Overfill Probe
Thermo-Optic Sensor with 2"NPT Probe Holder
FT151
FT155
Electronic 5 Channel Dummy
2 Wire Thermo-Optic Retain Sensor with ½" NPT Probe Holder
FT152
FloTech Thermo-Optic sensor and Thermistor Dummy are mechanically and functionally
compatible with Civacon Thermistor, Thermo-Optic and Thermistor Dummy components.
These "Electronic" Thermistor sensors will provide reliable operation when installed as
replacements to conventional "Green Tipped" Thermistor sensors. FloTech Thermo-Optic
sensors and electronic dummy provide high reliability, long life, and quick start up in cold
weather. "Civacon" is a registered trademarks of Civacon / Dover Corporation.
INSTALLATION INSTRUCTIONS:
FloTech model FT151 can be mounted in a 2"NPT female pipe coupling or through a 2 3/8"
hole. When mounting in a 2 3/8" hole the gasket and lock nut provided are used to retain the
probe holder in the tank shell or manhole. After the sensor is mounted remove the cap.
Loosen the probe clamp screw and adjust the probe to the correct level point. This is typically
3% of compartment volume. It is not recommended cutting the standard 7" sensor to a shorter
length. This will cause insufficient time to stop the flow of product within the load racks
reaction time.
IMPORTANT: The actual sensing point adjustment should be determined by the total
response time required to prevent a tank overfill condition. The FloTech sensor reaction time
is one half second. The loading rack will also have a reaction time. Once the probe is adjusted
to the proper height, tighten the clamp screw.
Rev: May 2017
Thermo-Optic Sensors and Thermistor Dummy
Dixon Bayco
4740T Interstate Dr. Cincinnati, OH 45246
PH: 513 874 8499 FX: 513 874 8399
Instruction Manual 10159
Page 1

Advertisement

loading

Summary of Contents for FloTech FT151

  • Page 1 “Civacon” is a registered trademarks of Civacon / Dover Corporation. INSTALLATION INSTRUCTIONS: FloTech model FT151 can be mounted in a 2”NPT female pipe coupling or through a 2 3/8” hole. When mounting in a 2 3/8” hole the gasket and lock nut provided are used to retain the probe holder in the tank shell or manhole.
  • Page 2: Wiring Instructions

    It is highly recommended to use FloTech FT401 jacketed 7-conductor cable when wiring a new system. FloTech cable is designed to be oil, UV, and abrasion resistant. We incorporate a noble tin plated stranded copper wire which resist corrosion. These features will provide years of reliable service.
  • Page 3 Diagram F1 Dixon Bayco 4740T Interstate Dr. Cincinnati, OH 45246 Rev: May 2017 PH: 513 874 8499 FX: 513 874 8399 Page 3...
  • Page 4 RETAIN SENSOR: FloTech model FT152 is designed to fit into a ½ NPT half coupling welded into the bottom of each compartment. The mounting location should be the lowest point of the tank. The collar should not protrude more than ¾ inch outside the tank and flush with the inside of the tank when possible.
  • Page 5 FloTech Capteur thermo-optique et résistance de charge fictive thermistance de “Dummy” DESCRIPTION DES PRODUITS: Ces instructions sont pour les produits FloTech suivants : FT150 Sonde thermo-optique anti-débordement de remplacement Sonde thermo-optique anti- débordement de remplacement de 12” FT150-12 Sonde thermo-optique anti- débordement de remplacement de 18”...
  • Page 6: Instructions D'installation

    Corporation. INSTRUCTIONS D’INSTALLATION: Le capteur FloTech modèle FT151 peut être vissé sur un coupleur femelle de 2” NPT ou peut être installé dans un trou de 2 3/8”. Lorsqu’il est installé dans un trou de 2 3/8” le joint d’étanchéité et l’écrou de blocage sont fournis pour retenir le boitier de la sonde dans la citerne ou dans le trou d’homme.
  • Page 7 Nous vous recommandons d’utiliser un câble FloTech lorsque vous installez un nouveau system. Le câble FloTech est conçu pour être résistant à l’huile, UV et à l’abrasion. Nous intégrons un fil en torons de cuivre étamé et plaqué résistants à la corrosion. Ces traits vous procureront des années fiables de service.
  • Page 8 Diagramme F1 10159(fr) Rev: May 2017...
  • Page 9 CAPTEUR DE FOND Le capteur de retenu modèle FT152 FloTech est conçu pour un coupleur NPT ½ ” soudé sur le dessous de chaque compartiment. Le point d’installation devrait être sur le point le plus bas de la citerne. Le col ne devrait jamais dépasser plus que ¾” à l’extérieur de la citerne et être égale à...