IP address of the network camera. The configuration tool can be found on our website at https://www.go1984.com. The default username is admin, and the default password is also admin. You should change the default password after logging in for the first time. Operation Manual Network Camera logiware IPC1901A...
IP address is 192.168.178.178 if there is no DHCP server in the network. After successful connection, the login interface is shown as in Figure 1-3; input your username and password. Default factory username is admin and password is admin. Figure 1-3 Operation Manual Network Camera logiware IPC1901A...
Page 6
After successful login, you may see the interface shown as in Figure 1-4. Figure 1-4 Click on “Please click here to download and install the plug-in”. The system pops up warning information to ask you whether run or save this plug-in. See Figure 1-5. Figure 1-5 Operation Manual Network Camera logiware IPC1901A...
Page 7
You must either run or save the file to local and install it. Follow the following steps. Click on run, you will see Figure 1-6 and Figure 1-7. Figure 1-6 Figure 1-7 Operation Manual Network Camera logiware IPC1901A...
Page 8
When plug-in installation completes, the installation page closes automatically. The web-end will refresh automatically, and then you can view video captured by the camera. Figure 1-8 Operation Manual Network Camera logiware IPC1901A...
After you logged in, you can see the live monitor window. See Figure 2-1. Figure 2-1 There are four sections: Section 1: Encode setup bar Section 2: System menu Section 3: Window function option bar Section 4: Window adjust bar Operation Manual Network Camera logiware IPC1901A...
There are three options: TCP/UDP/Multicast 2.2 System Menu System menu is shown as in Figure 2-3. Setting Please refer to chapter 2 Live, chapter , chapter 4 Alarm, chapter 5 Log out for detailed information. Figure 2-3 Operation Manual Network Camera logiware IPC1901A...
Click it to take snapshot upon the video at the frequency of one Snapshot picture per second. All images are saved to path in Ch 3.1.2.5. Record Click it to record the video. All videos are saved to path in Chapter 3.1.2.5. Operation Manual Network Camera logiware IPC1901A...
Please go to Setup->Camera contrastness. ->Conditions to adjust corresponding items. It is to adjust monitor video hue. It is to adjust monitor video saturation. Restore brightness, contrastness Reset saturation and hue to system default setup. Operation Manual Network Camera logiware IPC1901A...
There are three levels of fluency for you to select (Realtime, Normal, and Fluency). The default is normal. 2.4.6 Rules Info Click the button, preview image will display intelligent rules after enabling; it is “enable” by default. Operation Manual Network Camera logiware IPC1901A...
It is to adjust the picture contrast. The bigger the value is, the bigger the Contrast bright contrast becomes, and on the contrary it is smaller. The dark area becomes darker and the bright area becomes overexposed easily when the Operation Manual Network Camera logiware IPC1901A...
Page 15
Click “Save” and complete the image parameter configuration of the camera. 3.1.1.2 Exposure Step 1 Select “Setting > Camera > Conditions > Exposure”. The system will display the “Exposure” interface which is shown in Figure 3-2. Operation Manual Network Camera logiware IPC1901A...
Page 16
Shutter priority: The device can auto adjust according to the shutter range which is set by priority during normal exposure Operation Manual Network Camera logiware IPC1901A...
Page 17
Step 1 Select “Setting > Camera > Condition > Backlight”, the system will display the interface of “Backlight” which is shown in Figure 3-3. Operation Manual Network Camera logiware IPC1901A...
Page 18
When the “Mode” is set as “HLC”, the system will constrain the brightness of the area with high brightness and decrease the size of the halo area, which is to lower the brightness of the whole image. Step 3 Click “Save” to complete the configuration of the backlight mode. Operation Manual Network Camera logiware IPC1901A...
Page 19
When the “Mode” is set as “Regional Custom”, it is to set customized area, the system can compensate white balance to different color temperature of the images in the area, which is to make the image color normal. Operation Manual Network Camera logiware IPC1901A...
Page 20
Black & white: The camera image is displayed as black & white image. The parameter can be set when the “Day/Night Mode” is “Auto”. Sensitivity It is to set the sensitivity of the switch between image color display and black & white display. Operation Manual Network Camera logiware IPC1901A...
Page 21
When the “Mode” is set as “Smart IR”, the system can adjust the light brightness according to the actual scene. When the “Mode” is set as “Zoomprio”, the system can auto adjust the IR light according to the brightness change of the actual scene. Operation Manual Network Camera logiware IPC1901A...
Page 22
Figure 3-7 When the “Profile Management” is set as “Full Time”, you can select “Always Enable” in “Day” or “Night’, the system will monitor according to the configuration of “always enable”. Operation Manual Network Camera logiware IPC1901A...
Page 23
Figure 3-9 Step 3 Click “Save” to complete the settings of profile management. Note: Click “Default” to restore the device to default config; click “Refresh” to check the latest configuration file of the device. Operation Manual Network Camera logiware IPC1901A...
Please note, you can set video quality in VBR mode. Under MJPEG mode, only CBR is available. Recommended Bit Rate Recommended bit rate value according to the resolution and frame rate you have set. Operation Manual Network Camera logiware IPC1901A...
Page 25
Select “Watermark Setting” and enable watermark function. Watermark Settings After the watermark function is enabled, you can check if the video is tampered via verifying watermark character. It is the character of watermark verification; it is ‘logiware’ by Watermark Character default. Step 3 Click “Save”...
Page 26
3.1.2.3 Video Overlay The video overlay interface is shown as in Figure Figure 3-12 to Figure 3-15. Figure 3-12 Figure 3-13 Operation Manual Network Camera logiware IPC1901A...
Page 27
You can use the mouse to drag the time tile position. You can enable this function so that system overlays channel Channel Title information in video window. You can use the mouse to drag the channel tile position. Operation Manual Network Camera logiware IPC1901A...
Page 28
Check “Enable”, then it will display the ROI in the video monitoring window; Enable Check “Disable”, then it won’t display. Set the image quality of ROI, ranging from 1~6, default is 6. Image Quality Able to set area block, max 4 areas. Operation Manual Network Camera logiware IPC1901A...
Page 29
The default monitor image path is C:\Users\admin\WebDownload\LiveSnapshot. The default monitor record path is C:\Users\admin\WebDownload\LiveRecord. Note: admin is locally logged in PC account. Please click the Save button to save current setup. Figure 3-17 Operation Manual Network Camera logiware IPC1901A...
Please use the keyboard to input the corresponding number to modify the IP address and then set the corresponding subnet mask and the default gateway. Preferred DNS DNS IP address. Alternate DNS Alternate DNS IP address. Operation Manual Network Camera logiware IPC1901A...
Page 31
“Reply from 192.168.0.125 …” from the command output lines. Now you can close the command line. Step 6: Open the browse and then input http://<IP address>. Click the Enter button, you can access now. Operation Manual Network Camera logiware IPC1901A...
The IP is device IP and the port default value is 554. You can leave it in blank if it is the default value. Follow standard RTP protocol and when encode mode is MJPEG, the max resolution only supports 2040*2040. Operation Manual Network Camera logiware IPC1901A...
PPPoE setup interface, it will display the registered IP address, and then it can visit the IP address via client. Please disable UPnP when clicking PPPoE enable, which is to avoid causing influence to PPPoE dial-up. Figure 3-20 Operation Manual Network Camera logiware IPC1901A...
Server address: members.dyndns.org Mode Default is auto, able to choose manual Domain Name Enter your domain name from the respective DDNS service here. Username The user name you input to log in the server, optional. Operation Manual Network Camera logiware IPC1901A...
(Encryption mode) Title (Subject) Input email subject here. Attachment System can send out the email of the snapshot picture once you check the box here. Mail receiver Input receiver email address here. Max three addresses. Operation Manual Network Camera logiware IPC1901A...
Enable UPnP from the Web. If your UPnP is enabled in the Windows OS, the network camera can auto detect it via the “My Network Places”. Under manual mode, you can modify external port. Under auto mode, select idle port for auto port mapping without user modification. Figure 3-23 Operation Manual Network Camera logiware IPC1901A...
You can view the server name when the network camera is detected by the Bonjour. Please note the safari browse support this function. Click the “Display All Bookmarks: and open the Bonjour, system can auto detect the network camera of the Bonjour function in the LAN. Figure 3-24 Operation Manual Network Camera logiware IPC1901A...
Main/sub stream multicast default address is 224.1.2.4 and its range is Multicast address 224.0.0.0~239.255.255.255. Port Multicast port. Main stream is 40000, sub stream1 is 40016,sub stream2 is 40032 and the range is 1025~65534. Operation Manual Network Camera logiware IPC1901A...
(64 different priority levels) of the packets and select the bandwidth of the each queue. Level 0 is the lowest, and level 63 is the highest. It can also discard at the different ratio when the broad bandwidth is jam. Operation Manual Network Camera logiware IPC1901A...
Page 40
The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets. The value ranges from 0 to 63. The router or the switcher can provide Command different service for various data packets. Operation Manual Network Camera logiware IPC1901A...
ONVIF Standard’s aim is to achieve a network video frame agreement and makes the network video products (including video front-end, video equipment, etc.) from different manufacturers completely compatible. ONVIF function is on by default. Figure 3-28 Operation Manual Network Camera logiware IPC1901A...
Step 2 Select “Enable” to enable motion detection function. Step 3 Set motion detection area. 1. Click “Setup” and the system will pop out the interface of “Setting Area”, which is shown in Figure 3-30 Operation Manual Network Camera logiware IPC1901A...
Page 43
The red line in the Oscillogram means triggering motion detection; green line means not triggering motion detection. 3. Click “Save” to complete area setting. Step 4 It is to set other parameters of motion detection, please refer to the following sheet for more details. Operation Manual Network Camera logiware IPC1901A...
Page 44
You need to check the box here so that system can backup motion detection snapshot file. You shall set snapshot period in Storage>Schedule. Step 5 Click “Save” to complete the setting of motion detection. Operation Manual Network Camera logiware IPC1901A...
Page 45
System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s. Send Email If you enabled this function, System can send out email to alert you when alarm occurs and ends. User can set email address in Network>SMTP. Operation Manual Network Camera logiware IPC1901A...
Page 46
3. Click “Save” to complete the setup of working period. Operation Manual Network Camera logiware IPC1901A...
Select “Setting > Event > Smart Plan”. The system will display the interface of “Smart Plan”, which is shown in Figure 3-33. Figure 3-33 Step 2 Click “Save” to complete the configuration of smart plan. Operation Manual Network Camera logiware IPC1901A...
Try to keep away from the areas such as glass, ground reflected light, water surface, branch, shadow, mosquito disturbance and etc. try to keep away from the backlight scene to avoid direct light. Operation Manual Network Camera logiware IPC1901A...
Page 49
Select “Setting > Event > IVS > IVS” and the system will display the interface of “IVS”. Step 2 Click “ ” to set rule name and select the rule type as “Tripwire” which is shown in Figure 3-34. Figure 3-34 Operation Manual Network Camera logiware IPC1901A...
Page 50
User can set email address in Network>SMTP. Select “Snapshot” and the system will auto trigger alarm and snapshot Snapshot when alarm occurs. Step 5 Click “Save” to complete the setup of tripwire. Operation Manual Network Camera logiware IPC1901A...
Page 51
Step 4 Click “Draw Target” to draw the size model of filtered target in the video image. Step 5 It is to set the parameters of intrusion, please refer the following sheet for more details. Operation Manual Network Camera logiware IPC1901A...
Page 52
User can set email address in Network>SMTP. Select “Snapshot” and the system will auto trigger alarm and snapshot Snapshot when alarm occurs. Step 5 Click “Save” to complete the setup of intrusion. Operation Manual Network Camera logiware IPC1901A...
Abnormality includes Disconnection, IP Conflict and Illegal Access. Figure 3-36 When login password keep been wrong for a few times, unauthorized access alarm occurs. Allow login error times as when it exceeds this limit, user account will be locked. Figure 3-37 Operation Manual Network Camera logiware IPC1901A...
By checking or unchecking, you can add or delete two types of record schedule: Normal and Motion. Note: Period setup can be done by dragging in record schedule interface while not releasing left mouse. Figure 3-39 Operation Manual Network Camera logiware IPC1901A...
Page 55
Figure 3-40 Step 4. In record schedule interface, click on OK. System prompts it is successfully saved. 3.4.1.2 Snapshot Schedule Snapshot setup as: Step 1. Click on Snapshot Schedule tab, see Figure 3-41. Figure 3-41 Operation Manual Network Camera logiware IPC1901A...
Page 56
Step 2. Click on OK, return to snapshot schedule interface. See Figure 3-41. Green color stands for the normal record/snapshot. Yellow color stands for the motion detect record/snapshot. Figure 3-43 Step 5. In snapshot interface, click on OK. System prompts it is successfully saved. Operation Manual Network Camera logiware IPC1901A...
Page 57
Step 4. Check Record Schedule/Snapshot Schedule interface, click on setup next to Holiday, and refer to setup of Monday to Sunday. Step 5. Complete setup of holiday, then it records/snapshots according to date in holiday schedule. Operation Manual Network Camera logiware IPC1901A...
You need to check the box to enable the FTP function. When network disconnect occurred or there is malfunction. Emergency storage can save the record/snapshot picture to the local SD card. Click the test button to check if the FTP server can be connected for test. Figure 3-46 Operation Manual Network Camera logiware IPC1901A...
Page 59
NAS server. See Figure 3-47. Figure 3-47 Parameter Function Server Set IP address of NAS server. Address Remote Set storage directory, videos and pictures can be stored in to corresponding Directory server directory. Operation Manual Network Camera logiware IPC1901A...
Stop: Current working HDD is overwriting or current HDD is full, it will stop record. Overwrite: Current working HDD is full; it will overwrite the previous file. Record mode There are three modes: Auto/manual/close. Record There are two options: main stream and sub stream. stream Operation Manual Network Camera logiware IPC1901A...
Device Name It is to set device name. Note: Different devices have different names. Language You can select the language from the dropdown list. Video This is to display video standard such as PAL. Standard Operation Manual Network Camera logiware IPC1901A...
Page 62
NTP server You can set the time server address. Port It is to set the time server port. Update period It is to set the sync periods between the device and the time server. Operation Manual Network Camera logiware IPC1901A...
Here you can input the user name and password and then select one group for current user. Please note the user rights shall not exceed the group right setup. For convenient setup, please make sure the general user has the lower rights setup than the admin. Operation Manual Network Camera logiware IPC1901A...
Page 64
Please click the OK button to save. Please note, the password ranges from 0-digit to 32-digit. It shall include the number and letter only. For the user who has the account rights, he can modify the password of other users. Operation Manual Network Camera logiware IPC1901A...
Page 65
Add group: It is to add group and set its corresponding rights. See Figure 3-55. Please input the group name and then check the box to select the corresponding rights. It includes: preview, playback, record control, PTZ control and etc. Operation Manual Network Camera logiware IPC1901A...
Page 66
Figure 3-55 Modify group Click the modify group button, you can see an interface is shown as in Figure 3-56. Here you can modify group information such as remarks and rights. Figure 3-56 Operation Manual Network Camera logiware IPC1901A...
Here you can add IP address and MAC address. You must add these addresses before enabling the trusted sites. Please note: You must set MAC address in the same network segment. Figure 3-57 3.5.3.2 System Services Figure 3-58 Operation Manual Network Camera logiware IPC1901A...
Page 68
1. Select “Setting > Network > HTTPs”, and the system will display the interface of HTTPs, which is shown in Figure 3-59. Figure 3-59 2. Click “Create” and it will pop out the dialog box of “HTTPs”, which is shown in Figure 3-60. Operation Manual Network Camera logiware IPC1901A...
Page 69
Make sure the “IP or domain name” is the same as that of the device. 4. Click “Install” and it will install the certificate on the device end, which is shown in Figure 3-61. Operation Manual Network Camera logiware IPC1901A...
Page 70
5. Click “Download”. It will pop out the dialog box of “Save as”, save the file into the computer. Figure 3-62 6. Double click the downloaded icon of “RootCert.cer”. The system will display the information interface of “Certificate”, which is shown in Figure 3-63. Operation Manual Network Camera logiware IPC1901A...
Page 71
Figure 3-63 7. Click “Install Certificate” and it will pop out the interface of “Certificate Import Wizard”, which is shown in Figure 3-64. Operation Manual Network Camera logiware IPC1901A...
Page 72
Figure 3-64 8. Click “Next”. Select “Trusted Root Certification Authorities”, which is shown in Figure 3-65. Operation Manual Network Camera logiware IPC1901A...
Page 73
Figure 3-65 9. Click “Next”. The system will display the interface of “Completing the Certificate Import Wizard”, which is shown in Figure 3-66. Operation Manual Network Camera logiware IPC1901A...
Page 74
Figure 3-66 10. Click “Finish”, and it will pop out the dialog box of “Security Warning”, which is shown in Figure 3-67. Operation Manual Network Camera logiware IPC1901A...
Page 75
Please refer to the following steps if you select “Install Signed Certificate”. 1. Select “Setting > Network > HTTPs”. The system will display the interface of HTTPs, which is shown in Figure 3-69. Operation Manual Network Camera logiware IPC1901A...
Page 76
Use HTTPs to log in. Enter https://xx.xx.xx.xx in the browser, and it will pop out normal login interface; the browser will prompt certificate error if the certificate is not installed, which is shown in Figure 3-71. Operation Manual Network Camera logiware IPC1901A...
Page 77
Figure 3-71 Note: “xx.xx.xx.xx” is corresponding to your IP or domain name. Operation Manual Network Camera logiware IPC1901A...
Please refer to the following sheet for detailed information. Parameter Function Import It is to import the local setup files to the system. Export It is to export the corresponding system setup to your local PC. Operation Manual Network Camera logiware IPC1901A...
The upgrade interface is shown as in Figure 3-75. Please select the upgrade file (file extension is “.bin”) and then click the update button to begin firmware update. Important Improper upgrade program may result in device malfunction! Figure 3-75 Operation Manual Network Camera logiware IPC1901A...
Here you can view system hardware features, software version, release date and etc. Please note the following information is for reference only. Figure 3-76 3.5.9 Here you can view system log. See Figure 3-77. Figure 3-77 Operation Manual Network Camera logiware IPC1901A...
You can click this button to backup log files to current PC. 3.5.10 Online User The online user interface is shown as in Figure 3-78. Here you can view current online user, group name, IP address and login time. Figure 3-78 Operation Manual Network Camera logiware IPC1901A...
All trademarks and registered trademarks mentioned are the properties of their respective owners. If there is any uncertainty or controversy, please refer to the final explanation of us. Please visit our website for more information. Operation Manual Network Camera logiware IPC1901A...