3.2 Recommended Use
3.2 Recommended Use
Recommended use(s) of on-board duplex GFCI are shown.
Recommended use(s) of on-board duplex GFCI are shown.
Note: Standard 115 VAC electrical outlets.
Note: Standard 115 VAC electrical outlets.
15 Amp
Outlet
Phoenix
CAM
Phoenix
CAM
Phoenix
CAM
Phoenix
Phoenix 200 MAX
CAM
Figure 2: Duplex GFCI use
4 Operation Instructions
4 Operation Instructions
The Phoenix Centrifugal Air Mover Pro is intended for use
The Phoenix Centrifugal Air Mover is intended for use by
by water damage restoration, carpet cleaning, construction,
water damage restoration, carpet cleaning, construction,
and janitorial/sanitation professionals in general ventilating
and janitorial/sanitation professionals in general
and structural surface drying applications. The Phoenix
ventilating and structural surface drying applications. The
Centrifugal Air Mover Pro as packaged is ready to be put
Phoenix Centrifugal Air Mover as packaged is ready to
into service. Inspect the unit completely for any shipping
be put into service. Inspect the unit completely for any
damage. Place the unit on the ground. Check the GFCI to
shipping damage. Place the unit on the ground. Check
ensure it is not tripped. Plug the unit into a grounded outlet
the GFCI to ensure it is not tripped. Plug the unit into a
and select the drying mode.
grounded outlet and select the drying mode.
CAUTION: The Phoenix Centrifugal Air Mover consumes 2.7
CAUTION: The Phoenix Centrifugal Air Mover Pro consumes
Amps on high speed. Do not plug devices requiring more
2.6 Amps on high speed. Do not plug devices requiring more
than 9.3 Amps of current into the duplex outlet.
than 9.3 Amps of current into the duplex outlet.
5 Operator Panel Features
5 Operator Panel Features
5.1 12 Amp Resettable Circuit Breaker
5.1 12 Amp Resettable Circuit Breaker
The 2 AMP thermal response resettable circuit breaker
The 12 AMP thermal response resettable circuit breaker
protects the unit and devices connected to its duplex GFCI
protects the unit and devices connected to its duplex GFCI
outlet.
outlet.
The circuit breaker is designed to sense the total current
The circuit breaker is designed to sense the total current
draw through the circuit. The circuit breaker "trips" when
draw through the circuit. The circuit breaker "trips" when
more than 2 amps of electrical current are drawn through
more than 12 amps of electrical current are drawn through
the device's power cord. Should an over-current condition
the device's power cord. Should an over-current condition
occur, the Centrifugal Air Movers' on-board circuit breaker
occur, the Centrifugal Air Movers' on-board circuit breaker
trips thus preventing nuisance visits to a remote power
trips thus preventing nuisance visits to a remote power
junction box.
junction box.
To reset on board breaker, remove over drawing equipment.
To reset on-board breaker, remove over drawing equipment.
Allow to cool for 0 minutes and reset breaker.
Allow to cool for 10 minutes and reset breaker.
1.800.533.7533
Toll-Free 1-800-533-7533
15 Amp
15 Amp
Outlet
Outlet
Phoenix
Phoenix
CAM
CAM
Phoenix
Phoenix
CAM
CAM
Phoenix
CAM
Phoenix Mini-Guardian
IMP0RTANT: Total amperage of the Centrifugal Air Mover
IMPORTANT: Total amperage of the Centrifugal Air Mover
plus all devices plugged into the receptacle must not
plus all devices plugged into the receptacle must not
exceed 12 amps. The circuit breaker will not allow for loads
exceed 12 amps. The circuit breaker will not allow for loads
in excess of 12 amps, although there is a time delay before
in excess of 12 amps, although there is a time delay before
the overloaded circuit is broken.
the overloaded circuit is broken.
5.2 Power Indication Lamp
5.2 Power Indication Lamp
The red, sealed, high intensity AC voltage power indication
The red, sealed, high intensity AC voltage power indication
lamp allows operators to visually identify the operation
lamp allows operators to visually identify the operation
status of several Phoenix Centrifugal Air Mover Pros at a
status of several Phoenix Centrifugal Air Movers at a
distance, with a single glance. The power indication lamp
distance, with a single glance. The power indication lamp
will remain lit when the AC power cord is plugged into a
will remain lit when the AC power cord is plugged into a
standard "powered" AC power outlet and the
standard "powered" AC power outlet and the
3-Position drying selector switch is in either the HIGH or LOW
3-Position drying selector switch is in either the HIGH or
operation position. The power indication lamp will remain
LOW operation position. The power indication lamp will
unlit when the AC power cord is unplugged, the 3-Position
remain unlit when the AC power cord is unplugged, the
drying selector switch in the OFF position, the on-board
3-Position drying selector switch in the OFF position, the
GFCI or 12 Amp circuit breaker is tripped, or the connected,
on-board GFCI or 2 Amp circuit breaker is tripped, or the
standard AC wall outlet power has been turned off.
connected, standard AC wall outlet power has been turned
off.
5.3 3-Position Drying Selector Switch
The Phoenix Centrifugal Air Mover Pro features a three-
5.3 3-Position Drying Selector Switch
position switch - LOW–OFF–HIGH.
The Phoenix Centrifugal Air Mover features a three-position
1. Inspect the machine for damage and airflow
switch - LOW–OFF–HIGH.
obstructions prior to plugging it in or operating it.
. Inspect the machine for damage and airflow
2. Ensure the power switch is in the OFF (middle) position.
obstructions prior to plugging it in or operating it.
3. Place the machine into the desired position for
2. Ensure the power switch is in the OFF (middle)
operation. Ensure that the machine rests stable and
position.
secure and will not overturn.
3. Place the machine into the desired position for
4. Plug the power cord into a GFCI protected outlet. Do not
operation. Ensure that the machine rests stable and
use an extension cord in conjunction with the standard
secure and will not overturn.
power cord.
4. Plug the power cord into a GFCI protected outlet. Do
5. Turn the unit on to the desired speed, high or low.
not use an extension cord in conjunction with the
standard power cord.
5. Turn the unit on to the desired speed, high or low.
GFCI Outlet
GFCI Outlet
Stainless
Steel
Control
Stainless
Panel
Steel
Control
Panel
Figure 3: Centrifugal Air Mover Pro Operator
Panel
Figure 3: Centrifugal Air Mover Operator Panel
USEPHOENIX.COM
4
4
12 Amp
Circuit Breaker
2 Amp
Circuit Breaker
www.usephoenix.com • sales@thermastor.com
AC Indicator
Lamp
AC Indicator
Lamp
High Speed:
"Ultra"
High Speed:
Drying Power
"Ultra"
Drying Power
Low Speed:
Quiet Operation
Low Speed:
Quiet Operation
Need help?