Page 2
ComBricks is a registered trademark of PROCENTEC. Other products or company names are or may be registered trademarks and are the property of their respective companies.
2292 JD WATERINGEN The Netherlands T: +31-(0)174-671800 F: +31-(0)174-671801 E: info@procentec.com Document Updates You can obtain constantly updated information on PROCENTEC products on the Internet at www.procentec.com You can also contact PROCENTEC Customer Support: • by phone at +31-(0)174-671800 •...
DB9 connector and NOT on the repeater module (see Fig. 21 - configuration C) If you choose to use the DB9 connector, it is recommended to use the PROCENTEC ProfiConnector (any type), because this connector has the correct shape to fit over the green connector. See our website for more information about this connector.
Network Event log. You can also select for which network this should apply. The interface language can be changed in the Preferred Language drop-down box. More languages are available as a separate download called ‘Language Pack’ on the website of PROCENTEC. Network configuration The network names and the assignment of the repeater modules are customized here.
SD card. If you are interested in such activities, we recommend you to inspect the structure of the PROCENTEC index.html first. Please note that the FTP process has a low priority in the ComBricks, so transfer of larger files may be slow.
If you mix ComBricks with other repeaters you only have to follow the cascading rules of the other repeater manufacturer. If the other repeaters are also from PROCENTEC, you can cascade and mix without problems. Keep in mind that monitoring will fully work, but the SCOPE repeaters only measure the signals up to the first repeater module.
Page 79
In the upper menu, choose ‘Device – Add device’ and click on ‘PROCENTEC DP-V1 Master’, as shown in Fig. 55. Select PROCENTEC and Select PROCENTEC and choose the DP-V1 Master choose the DP-V1 Master Fig. 55 - CommDTM selection dialog After clicking ‘OK’...
Page 80
In PACTware, make sure to set the correct bus parameters by right-clicking the PROCENTEC DP-V1 master and choose ‘Parameters’. Enter the correct parameters or select ‘Start’ to auto-detect these (see Fig. 56). Then click ‘OK’. Next, choose the icon ‘Connect’ from the top menu.
2. Download the MIB file and place it in C:\Program files (x86)\Snmpb\mibs\ 3. Start SNMPb and click the tab ‘Modules’. Search for the module ‘PROCENTEC-COMBRICKS-HS-T1-MIB’, select it and click the button -> so that the module moves to the right table. It is now loaded.
Page 102
17. About PROCENTEC PROCENTEC is a specialist in PROFIBUS and PROFINET technology and develops products to optimize the production processes of end users. Our innovative solutions ensure that our customers successfully operate in the world of industrial automation and enjoy maximum results from their process.
Need help?
Do you have a question about the ComBricks HE+ and is the answer not in the manual?
Questions and answers