ABB ZMT Zirconia Manual page 3

Oxygen analyzer systems
Table of Contents

Advertisement

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182E-MAIL: szss20@163.com
Identification Table for ZMT
Basic
Probe
Ref. Air
Type
Type
Supply
Ref.
(See
Note 2)
Code
Digit
Nos.
1,2,3
/4
5
1 ZGP2 0
None
1
Pump+Air
Gauge
4
Regulator
2 ZFG2
0
None
ZMT
2
Regulator
3
Pump
3 Other
0
None
1
Pump+Air
Gauge
4
Regulator
Note 1.
Fuel options available:
00 No fuel specification
01 Natural gas
02 Propane
03 Butane
04 Medium oil
05 Heavy oil
06 General fuel oil
07 Naphtha
08 Kerosene
ZMT Dimensional Details
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL: szss20@163.com
SS ZMT
Probe
Fuel
Efficiency
Temp.
Option
Control
(See
Note 1)
/6
7,8,9,10
11
0 None
0 None
1st
2nd
00
00
01
01
02
02
03
03
04
04
05
05
06
06
1 Temp.
1
Efficiency
07
07
Control
08
08
2
Humidity
09
09
10
10
11
11
12
12
0
None
13
13
14
14
1
Temp.
15
15
control
16
16
17
17
09 Distillate oil
10 No. 4 fuel oil
11 No. 5 fuel oil
12 No. 6 fuel oil
13 Coal (general)
14 Bituminous coal
15 Steam coal
16 Anthracite
17 Coke
Unused
Output
Module 1
12
/13
0 None
0
None
4
Analog
+ Relay
0 None
0
None
4
Analog
+ Relay
Note 2.
Reference air options 2 and 3 have the air outlet inside the
enclosure to suit ZFG2 probe type. Flow rate 500 to 1000 ml/
min (0.11 to 0.22 gal/min.) approx.
Reference air options 1 and 4 for use on ZGP2 probe types
have both inlet and outlet connections external to the
enclosure.
Approvals
CEGB Approval Number 51042A0114 (5124A24) Issue 5.
Lloyds Approval for shipboard use obtained and awaiting
certificate.
Quality Assurance to BS5750 Part 1. Certificate number
Q5907.
AN-79
Output
Output
Module 2
Module 3
14
15
0
None
0
None
1
1
One relay
1
One
2
Relay
2
Two relays
4
Analog
+ Relay
0
None
0
None
1
One
1
One Relay
Relay
2
Two Relays
4
Analog
+ Relay
4
Analog
+ Relay
Mains
Voltage
16
110V
50/60Hz
230V
50/60Hz

Advertisement

Table of Contents
loading

Table of Contents