Installation
Important: Before connecting all of the components together, please review the following specifications
in regards to the Flow Pump Manifold HUB and appropriate connections.
Pump Power
DC Input
Pump
Connection
P1
Flow Pump
Manifold HUB
Port#3
Port#4
MicroUSB Ports
(all for communication)
Connecting Pump to Manifold HUB
Step 1. Plug DC pump cable into pump connection on manifold HUB.
Step 2. Plug 24VDC power supply into DC input on manifold HUB.
Step 3. Red LED status light should turn solid red. Adjust flow from 0-100% using dial until
flow rate is acheived. NOTE: eFlux DC pumps have a slow ramp to speed, allow pump
to run for 10-15 seconds for pump to reach adjusted flow.
AC Power
GFCI Outlet
Note: FEED mode will only operate when DC pump is plugged into a manifold HUB with an Orbit IC
controller, eFlux wave pump controller or the HUB is controlled via Bluetooth. When in FEED
mode, DC flow pump will ramp down to 30% flow for 10 minutes, then ramp to normal speed.

Pump Maintenance

**Important - Due to harsh conditions found around marine aquariums, it is important to perform the
following pump maintenance every 6 months. When performing any maintenance or service, ensure
pump is disconnected from power and manifold HUB.
1. Remove pump from service by disconnecting power and removing pump from sump via disconnect
fittings.
2. Carefully remove front pump cover, o-rings and slide impeller from pump. Use a small soft brush and
running freshwater to clean any organic debris. If any calcium deposits have developed, soak the
components in mild vinegar/freshwater solution. DO NOT use strong acids.
3. Re-assemble pump, reconnect fittings with all o-rings properly in place and reconnect power.
Pump Dial
Flow Control
Communication LED
Indicator Lights
E
D
C
B
A
Port#1
Port#2
24VDC
Transformer
Installation Instructions

Specifications:

Pump DC Inputs:
Voltage: 24VDC
Max. DC Input per Channel: 120w@24VDC
Max. DC Output per Channel: 80w@24VDC
Indicator LEDs:
A (Blue)= Indicates 1050 gph pump is connected
B (Blue)= Indicates 1900 gph pump is connected
C (Blue)= Indicates 3170 gph pump is connected
D (Blue)= Feed - flashes when pump is in feed mode
E (Red)= Active feedback/pump status:
Red Solid - indicates pump is operating normal
Red Flashing - indicates non-normal operation
(pump running dry, over voltage
over/under voltage, over temperature)
Connect to DC Input
Connect to Pump Input
Flow Pump
Manifold HUB
Page 4
P3
P2
P1
To other LOOP
Manifold HUBS