E. Reviewing and/or Cancelling Timed Alert Tones (Dip Switch 2 OFF)
Step 1. Press the MODE button repeatedly until the REVIEW/CANCEL indicator lights.
Step 2. Set dip switch 3 to off to review and/or cancel events in schedule 1
Press one of the ALERT TONES buttons (single, double, or triple) repeatedly to rotate
through the event times associated with that alert tone button. A red LED at the bottom
right corner of the time display will light to indicate a buzzer event time (versus a bong
Step 3.
event). The CTG-1A will indicate the end of the programmed events for that ALERT
TONE button by displaying three dashes (- - -) before it returns to the first programmed
event. Note: Event times are stored in the order of programming, not chronologically.
Press the -/CANCEL button to permanently cancel an event tone. A single
Step 4.
acknowledgement tone will be heard. The next consecutive event for that specific alert
tone will then be displayed.
Step 5. Repeat steps 3 - 5 as needed to remove the events to be cancelled in that schedule.
If you need to review and/or cancel events in schedule 2, set dip switch 3 to on and
Step 6.
repeat steps 3 through 5.
F. Setting Timed Relay Times (Dip Switch 2 ON)
Step 1. Press the MODE button repeatedly until the EVENTS indicator lights.
Step 2. Set dip switch 3 to off to program relay times in schedule 1.
Increase or decrease the event time by pressing the TIME (+ or -/CANCEL) button until
Step 3.
the desired time is shown for a relay on or off event. Press and hold the + or -/CANCEL
to speed up the selection.
Press the single ALERT TONE button if the displayed time is a relay on event time or
Step 4.
the double or triple ALERT TONE buttons if the displayed time is a relay off event time.
Step 5. Repeat steps 3 and 4 for the remainder of your scheduled relay events in that schedule.
If you need to program timed relay events in schedule 2, set dip switch 3 to on and
Step 6.
repeat steps 3 through 5.
G. Reviewing and/or Cancelling Timed Relay Times (Dip Switch 2 ON)
Step 1. Press the MODE button repeatedly until the REVIEW/CANCEL indicator lights.
Step 2. Set dip switch 3 to off to review and/or cancel events in schedule 1.
Press the single ALERT TONE button repeatedly to rotate through the relay on event
times. Press the double or triple ALERT TONE buttons repeatedly to rotate through the
relay off event times. The CTG-1A will indicate the end of the programmed events for
Step 3.
that ALERT TONE button by displaying three dashes (- - -) before it returns to the first
programmed event. Note: Event times are stored in the order of programming, not
chronologically.
Press the -/CANCEL button to permanently cancel a relay event time. A single
Step 4.
acknowledgement tone will be heard. The next consecutive relay on or off event for that
alert tone button will then be displayed.
Repeat steps 3 and 4 as needed to remove any other relay on or off events in that
Step 5.
schedule.
If you need to review and/or cancel relay on or off events in schedule 2, set dip switch
Step 6.
3 to on and repeat steps 3 through 5.