Table of Contents

Advertisement

ELF System
Copper / Fiber :: ELF Family
User Manual
Applys to : ELF-1008-1100 :: ELF-1008-1200 :: ELF-1008-1800 :: ELF-3006-1100 :: ELF-3006-1800
ELF-9704-1119 :: ELF-3004-1800 :: ELF-3206-1200 :: ELF-3206-1900 :: ELF-PC12-SC00
ELF-9716-1900 :: ELF-9716-1700 :: ELF-0005-0001 :: ELF-PC12-FC00 :: ELF-SP12-SCPT
ELF-
12-
SP
FCPT
© Telect, Inc., All Rights Reserved, 124317-10 A0
1.509.926.6000 :: telect.com
:: ELF-
12-
00 :: ELF-
PC
SA
SP12-SAPT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELF-1008-1100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Telect ELF-1008-1100

  • Page 1 ELF System Copper / Fiber :: ELF Family User Manual Applys to : ELF-1008-1100 :: ELF-1008-1200 :: ELF-1008-1800 :: ELF-3006-1100 :: ELF-3006-1800 ELF-9704-1119 :: ELF-3004-1800 :: ELF-3206-1200 :: ELF-3206-1900 :: ELF-PC12-SC00 ELF-9716-1900 :: ELF-9716-1700 :: ELF-0005-0001 :: ELF-PC12-FC00 :: ELF-SP12-SCPT...
  • Page 2: Table Of Contents

    1.5.4 Technical Support (USA) ..................14 1.6 Specifications ........................14 Chapter 2: ELF DS1 Modules .....................17 2.1 ELF 8-Termination DSX-1, Wire-Wrap I/O (Model ELF-1008-1100) ......17 2.2 ELF 8-Termination DSX-1, BNC I/O (Model 1008-1200) ..........19 2.3 ELF 8-Termination DSX-1, RJ48C I/O (Model ELF-1008-1800) ........21 2.4 ELF 6-Termination DSX-1, Wire-Wrap I/O (Model ELF-3006-1100) ......
  • Page 3 Figure 10 - ELF Lockable Wall-Mount Dimensions............. 12 Figure 11 - Model ELF-1008-1100 Dimensions ..............17 Figure 12 - Model ELF-1008-1100 Reference Schematic ..........18 Figure 13 - Model 1008-1200 Dimensions ................19 Figure 14 - Model 1008-1200 Reference Schematic ............20 Figure 15 - Model ELF-1008-1800 Dimensions ..............
  • Page 4: Chapter 1: Descriptions

    1.1 ELF Copper/Fiber System Telect’s ELF System is a small “edge” connection system for use in locations where equipment density — maximum density with simplified monitoring — is important. The ELF System is ideal for a 3G, 4G, LTE wireless network at a base transceiver station (BTS), customer premises, controlled environment vault, co-location, or at any remote network terminal.
  • Page 5 • RJ48C XC • 3-Port Bantam Patch Jacks DNI-1 NOTE: All DS1 and DS3 Total Front Access and 12x4 Alarm Pin Block ELF Modules fit Telect’s ELF Wall Bracket (ELF-000-0600). © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 6 • Fiber Jumpers from ELF-PC12-FC00 FRONT — • Fiber Adapters NOTE: All DS1 and DS3 Total Front Access and 12x4 Alarm Pin Block ELF Modules fit Telect’s ELF Wall Bracket (ELF-000-0600). © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 7 Splice Module • Fiber Adapters General Purpose Signal Management NOTE: All DS1 and DS3 Total Front Access and 12x4 Alarm Pin Block ELF Modules fit Telect’s ELF Wall Bracket (ELF-000-0600). © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 8: Elf Mounting Options

    ELF-0005-0001 Pin Block Block (See Note.) NOTE: All DS1 and DS3 Total Front Access and 12x4 Alarm Pin Block ELF Modules fit Telect’s ELF Wall Bracket (ELF-000-0600). 1.3 ELF Mounting Options 1.3.1 ELF Chassis (Model ELF-0000-2400) • High-density 1RU chassis accommodates three ELF modules.
  • Page 9: Figure 1 - Elf Chassis Mounting Options

    Positioned for Panel Flush or 1-in. Extended Mounting. FRONT VIEW 17.25 (438.2) 3.5 (88.9) 5.00 (127.0) REAR VIEW #8-32 Ground Stud and KEPS Nut Figure 1 - ELF Chassis Mounting Options © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 10: Wall-Mount Elf Chassis Bracket (Elf-0000-0900)

    “footprint” or to hug the wall or cabinet with a minimum profile. Wall-mounting hardware is not included. Figure 4 - Bracket © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 11: Figure 5 - Wall-Mount Elf Chassis Bracket Dimensions

    Figure 5 - Wall-Mount ELF Chassis Bracket Dimensions Typical wall installations are shown in the following illustrations. Telect recommends that the tie bar on the rear of the ELF Chassis be removed when installing in the Wall-Mount ELF Chassis Bracket. Also, when installing rear access ELF modules, Telect recommends including a minimum 2-ft (600-mm) service loop for any cabling or wiring intended for the rear of the ELF module(s).
  • Page 12: Figure 6 - Wall-Mount Elf Chassis Bracket Installation

    Copper / Fiber :: ELF Family Rear Tie Bar Hugging a Wall Removing Tie Bar ELF Chassis GND Stud Extending from a Wall Figure 6 - Wall-Mount ELF Chassis Bracket Installation © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 13: Elf Wall Bracket (Model Elf-0000-0600)

    4.50 (114.3) 1.78 0.12 1.00 (25.4) (54.2) (3.0) Figure 7 - ELF Wall Bracket Dimensions The following illustration shows a typical installation. Figure 8 - Typical ELF Wall Bracket Installation © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 14: Elf Lockable Wall-Mount Enclosure (Model Elf-0000-0800)

    Mounting screws are not supplied Ground Strap & Lock Washer are not supplied ELF Module (Typical) Screws are supplied with ELF Module Figure 9 - ELF Lockable Wall-Mount Enclosure © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 15: Figure 10 - Elf Lockable Wall-Mount Dimensions

    4.6 (.18) Dia. 9.4 (0.37) 38.1 (1.5) REAR VIEW (ROTATED) 63.5 (2.50) TOP VIEW 172.9 (6.81) 3.00 (0.12) 236.79 (9.32) FRONT VIEW Figure 10 - ELF Lockable Wall-Mount Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 16: System-Level Applications

    CAUTION! Only qualified technicians may install and maintain this product. ALERT ALERT! These instructions presume you have verified that the Telect equipment being installed is compatible with the rest of the system, including power, ground, circuit protection, signal characteristics, equipment from other vendors, and local codes or ordinances.
  • Page 17: Inspection

    When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Telect Quality at quality@telect.com or call 1.509.926.6000. Telect is not liable for transit damaged. If the product is damaged, please report it to the carrier and contact Telect Quality.
  • Page 18 Contact Resistance <0.01 Ohms Characteristic Impedance 75 Ohms Table 3 - Fiber Optics Specification Return Loss >55 dB Insertion Loss <0.5 dB Mode Single Bandpass 1310/1550 ± 20 nm © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 19 ELF System Copper / Fiber :: ELF Family This page was intentionally left blank © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 20: Chapter 2: Elf Ds1 Modules

    • All three ELF DSX-1 8-Termination Modules feature network element RJ45, BNC, or wirewrap connections on the rear and Telect’s Bantam patch/monitor jacks and wire-wrap crossconnections on the front. • Both ELF DSX-1 6-Termination Modules are total front access modules. Wire-wrap network element, wire-wrap cross-connections, and Bantam patch/monitor jacks are all on the front.
  • Page 21: Figure 12 - Model Elf-1008-1100 Reference Schematic

    Copper / Fiber :: ELF Family RESISTOR VALUE = 475 ohm REFERENCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) X-CON S. GND. S. GND. Figure 12 - Model ELF-1008-1100 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 22: Elf 8-Termination Dsx-1, Bnc I/O (Model 1008-1200)

    DSX-1 Bantam Jacks Top View Jumper Tie-Down Bar 5.50 (139.7) Cross-Connect Pins 0.55 5.11 (129.7) (13.9) 5.86 (148.8) Network Element BNC Jack Field Figure 13 - Model ELF-1008-1200 Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 23: Figure 14 - Model 1008-1200 Reference Schematic

    Copper / Fiber :: ELF Family RESISTOR VALUE = 475 ohm REFERENCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) X-CON S. GND. 75/120 OHM Figure 14 - Model ELF-1008-1200 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 24: Elf 8-Termination Dsx-1, Rj48C I/O (Model Elf-1008-1800)

    DSX-1 Bantam Jacks Top View Jumper Tie-Down Bar 5.50 (139.7) Cross-Connect Pins 0.55 5.11 (129.7) (13.9) 5.86 (148.9) Network Element RJ48C Jack Field Figure 15 - Model ELF-1008-1800 Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 25: Figure 16 - Model Elf-1008-1800 Reference Schematic

    Copper / Fiber :: ELF Family RESISTOR VALUE = 475 oh m REFERENCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) X-CON S. GND. S. GND. Figure 16 - Model ELF-1008-1800 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 26: Elf 6-Termination Dsx-1, Wire-Wrap I/O (Model Elf-3006-1100)

    Figure 17 - Model ELF-3006-1100 Dimensions RESISTOR VALUE = 475 ohm REFERE NCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) X-CON S. GND. S. GND. Figure 18 - Model ELF-3006-1100 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 27: Elf 6-Termination Dsx-1, Rj48C I/O (Model Elf-3006-1800)

    Figure 19 - Model ELF-3006-1800 Dimensions RESISTOR VALUE = 475 ohm REFERENCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) X-CON RJ SHIELD GND. CHASSIS GND. Figure 20 - Model ELF-3006-1800 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 28: Elf 4-Circuit Dni-1, Wire-Wrap I/O To Rj48C I/O (Model Elf-9704-1119)

    DNI-1 Bantam Jacks Interconnect Jumper Top View Tie-Down Bar 5.50 (139.7) NE-2 RJ48C Jack Field 0.55 5.11 (129.7) (13.9) 5.86 (148.8) NE-1 Interconnect Pinfield Figure 21 - Model ELF-9704-1119 Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 29: Figure 22 - Model Elf-9704-1119 Reference Schematic

    ELF System Copper / Fiber :: ELF Family RESISTOR VALUE = 475 ohm NE-1 T IN NE-1 S. GND. NE-2 CHASSIS GND. NE-2 Figure 22 - Model ELF-9704-1119 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 30: Elf 4-Circuit Dni-1, Rj48C I/O To Rj48C I/O (Model Elf-3004-1800)

    Figure 23 - Model ELF-3004-1800 Dimensions RESISTOR VALUE = 475 ohm REFERENCE SCHEMATIC (TYPICAL FOR ALL CIRCUITS) NE-1 RJ SHIELD GND. CHASSIS GND. NE-2 Figure 24 - Model ELF-3004-1800 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 31 ELF System Copper / Fiber :: ELF Family This page intentionally left blank © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 32: Chapter 3: Elf Ds3 Modules

    Copper / Fiber :: ELF Family Chapter 3: ELF DS3 Modules Telect offers two DSX-3 ELF Modules. Both feature 6-port mini-WECOs for temporary I/O and cross-connect patching, testing, and monitoring, along with BNC connectors for normal NE I/O and cross-connections: •...
  • Page 33: Figure 26 - Model Elf-3206-1200 Reference Schematic

    ELF System Copper / Fiber :: ELF Family R1=75 OHM 1/4W R2=768 OHM 1/4W FRONT REAR REFERENCE SCHEMATIC Figure 26 - Model ELF-3206-1200 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 34: Elf 1-Termination Dsx-3, Tfa Bnc I/O (Model Elf-3206-1900)

    0.55 5.11 (129.7) (13.9) 5.86 (148.8) Figure 27 - Model ELF-3206-1900 Dimensions R1=75 OHM 1/4W R2=768 OHM 1/4W FRONT REAR REFERENCE SCHEMATIC Figure 28 - Model ELF-3206-1900 Reference Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 35 ELF System Copper / Fiber :: ELF Family This page intentionally left blank. © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 36: Chapter 4: Elf Fiber Modules

    Copper / Fiber :: ELF Family Chapter 4: ELF Fiber Modules Telect manufactures two Fiber ELF platforms for patching, and patching with splicing: • ELF Fiber Patch (Models ELF-PC12-SC00, ELF-PC12-FC00, ELF-PC12-SA00, and ELF-PC24-LC00) • ELF Fiber Splice/Patch (Models ELF-SP12-SCPT, ELF-SP12-FCPT, and ELF-SP12-SAPT) All modules are available with either 12, SC/UPC, FC/UPC, SC/APC, or 24 LC/APC adapters.
  • Page 37: Elf Fiber Splice/Patch Modules (Model Series Elf-Sp12)

    Fiber Patch Adapters Label 7.21 (183.1) 5.24 (133.0) 0.87 (22.0) 5.90 (148.8) Top View Gland-Style Compression Connector for 12-Strand IFC/OSP Subunit Figure 31 - Model Series ELF-SP12-XXPT Parts & Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 38: Figure 32 - Splice Cassette

    Designation Label Splice Deck Adapters (12) Figure 32 - Splice Cassette Subunit Clamp (2) Inner Race for Pigtails Spool Outer Race for Subunit Figure 33 - Subunit Entrance Compartment © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 39: Figure 34 - Elf Splice/Patch Module

    12 fiber strands (Model ELF-SP12-SCPT). From From Adapters Subunit From From Subunit Adapters connect ing t he f ut ur e Figure 34 - ELF Splice/Patch Module (Model ELF-SP12-SCPT Typical Cabling) © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 40: Chapter 5: Elf Multi-Purpose Modules

    Copper / Fiber :: ELF Family Chapter 5: ELF Multi-Purpose Modules Telect manufactures three multi-purpose signal manager modules for RJ45C and pin-block signals. All signal manager modules are straight feed-through: • The ELF RJ45C to RJ45C Patch Module (Model ELF-9716-1900) contains 16 RJ45C connectors on the rear which interconnect with 16 RJ45C connectors on the front.
  • Page 41: Elf Rj45C To Rj45C Patch Module (Model Elf-9716-1900)

    5.50 (139.7) 0.55 (13.9) 1.62 (41.3) RJ45C Connectors 5.86 (148.9) Figure 35 - Model ELF-9716-1900 Parts & Dimensions FRONT RJ SHIELD CHASSIS REAR Figure 36 - Model ELF-9716-1900 Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 42: Elf Rj45-Idc Patch Module (Model Elf-9716-1700)

    Please see Telect Publication 129039 for detailed instructions on installation and wiring. WH/BL Pair 1 WH/GR Pair 2 WH/OR Pair 3 WH/BR Pair 4 Figure 38 - Model ELF-9716-1700 Schematic © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 43: Elf 12 X 4 Alarm Pin Block Module (Model Elf-0005-0001)

    ELF 12 x 4 Alarm Pin Block Alarm Interconnects (Model ELF-0005-0001) 1.63 (41.3) 2.26 (57.4) Alarm I/O Cross-Connects Jumper Tie-Down 5.88 (149.4) Figure 40 - Model ELF-0005-0001 Parts & Dimensions © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 44: Chapter 6: Service

    Contact your Telect equipment distributor, or call a Telect Customer Service Representative: 1-509-926-6000 Telect will repair or replace defective products within the limits of the warranty. See “Repacking for Shipment” in this section. Call a Customer Service Representative for a Return Material Authorization (RMA) before returning any equipment.
  • Page 45: Chapter 7: Accessories

    Single RG59 043-0111-xxx where without messenger wire xxx is length in ft Single 735A 043-0911-xxx where without messenger wire xxx is length in ft BNC Insertion & Removal Tool 097197 © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 46 Plugs (Black or White) or PLG-MW-WHT RJ48C Jumpers CAT 5ePatch Cords EPCE-CT5E-BLXX where xx is length in ft CAT 6 Patch Cords EPCE-CAT6-BLXX where xx is length in ft © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 47 Circuit Designations (Self-adhesive circuit designation labels are provided with modules. Order the labels list here as replacements.) 8 Terminations 123958 1 to 4 Terminations 129396 12 Fiber Terminations 127380 connect ing t he f ut ur e © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...
  • Page 48 ELF System Copper / Fiber :: ELF Family This page intentionally left blank. © Telect, Inc., All Rights Reserved, 124317-10 A0 1.509.926.6000 :: telect.com...

Table of Contents