Magnetic Autocontrol MAGSTOP MIB 10-C090 Operating Instructions Manual

Traffic barrier

Advertisement

Quick Links

Operating Instructions

Operating Instructions
MAGSTOP Traffic Barrier
MIB 10-C090
Controller Unit
1
581E,5005/6.00

Advertisement

Table of Contents
loading

Summary of Contents for Magnetic Autocontrol MAGSTOP MIB 10-C090

  • Page 1: Operating Instructions

    Operating Instructions Operating Instructions MAGSTOP Traffic Barrier MIB 10-C090 Controller Unit 581E,5005/6.00...
  • Page 2 Operating Instructions  2000 by Magnetic Autocontrol GmbH, 79650 Schopfheim, Germany...
  • Page 3: General Safety Information

    Operating Instructions 1. Safety 1.1 General safety information This MAGSTOP gate system has been designed, built and tested using state-of-the- art technology and left our factory only after having satisfied stringent safety and reliability criteria. Nevertheless the gate system can represent a risk to persons and property if it is not operated correctly.
  • Page 4: Operational Safety

    Operating Instructions 1.4 Operational safety A safe clearance distance of at least 500 mm must be provided between the tip of the gate arm and the closest solid obstacle (building, wall, fence etc.). The gate operating elements must be installed at a position from which the gate can be seen directly.
  • Page 5: Assembly And Installation

    Operating Instructions 2. Assembly and installation 2.1 Constructing the foundation for the MIB gates and the MEC-10 N/H/L control pillar To ensure that the units are stable even when loaded, a foundation with the following dimensions must be provided: Depth of foundation: at least 800 mm (frost-free) Base area of foundation: 500 x 600 mm...
  • Page 6 Operating Instructions Distance between drill holes: 190 mm (arranged in a square, see Fig. S0101) Hole diameter: 10 mm Depth of hole: 80 mm Once the holes have been drilled, the four M8 x 160 shear connectors can be set in place.
  • Page 7 Operating Instructions • The supply line to the loop must not be longer than 15 m. The cable must not be coiled up within the barrier housing but should be cut to the appropriate length instead. The supply cable must be twisted about twenty times per metre. Once the loop has been installed, a check must be made that the resistance is <...
  • Page 8 Operating Instructions • When installing an induction cable beneath paving stones, a ready-to-install cable (type: KAS 1-KAS 5) from Magnetic must be used. • The induction loop cable must be laid in sand in such a way that its length is unchanged and it suffers no damage when vehicles are passing the barrier.
  • Page 9 Operating Instructions 4 plain washer 5 plain washer 6 masonry anchor 7 U-section 8 concrete foundation 2.4 Installing the flange and the barrier boom The flange is fastened to the drive shaft using two M10 x 35 hexagon socket screws and spring washers.
  • Page 10: Power Supply Connection

    Operating Instructions 1. Open the gate door, swing out the mounting plate, unlock the cover and remove. 2. Disconnect the power supply. 3. The gate arm will open automatically. Readjusting the spring settings: 1 Remove the two safety clips from both spring adjustment screws. Tighten or loosen the screws on the left and the right uniformly until the gate arm move automatically to the open position, when power failure occurs.
  • Page 11 Operating Instructions For this the gate arm will open slowely to the upper position. The motor lever will press the end stop of this direction for some seconds. Then the motor lever will move a few degrees back to it’s normal end position OPEN. The first movement into the closed position will be done by a very low speed (appr.
  • Page 12 Operating Instructions 581E,5005/6.00...
  • Page 13 Operating Instructions 5.1. Command generators: their connection and function in the different operating modes Important note: All command generators (e.g. push buttons, light barriers, limit switches) must be connected as voltage-free contacts. Contact Magnetic for advice before connecting command generators with open collector outputs. Program 1 (Mode 3): The gate is controlled by two switches.
  • Page 14: Technical Data

    Operating Instructions 6. Technical data 6.1 MAGSTOP barrier MIB 10 Maximum boom length max. 3000 mm round boom dia. 75mm Maximum boom length max. 2500 mm octogonal boom 100x55mm Opening/closing time 0, 6/1.2 sec adjustable via software-tool Power consumption max. 480 W Housing zinc-plated sheet steel color RAL 2000...
  • Page 15: Technical Support

    Operating Instructions 7.Technical support If operational faults arise which cannot be dealt with by your technical staff, please contact our authorized customer service agents or specialist suppliers for assistance. When contacting our technical support service please have available the barrier type, serial number, version, etc.