Page 3
SIGLENT Copyright SIGLENT TECHNOLOGIES CO., LTD. All rights reserved. ○ Information this publication replaces previous corresponding material. SIGLENT reserves the rights to change the specifications and the price. Without permission, contents in this manual are not allowed to be copied, extracted or translated.
Page 4
SIGLENT General Safety Summary Carefully read the following safety precautions to avoid any personal injuries or damages to the instrument and any product connected to it. To avoid potential hazards, please use the instrument as specified. Only the qualified technician can service the instrument. Avoid fire or personal Injure.
SIGLENT Content General Safety Summary .............. II Adjust the Handle ................. 1 The Front Panel ................2 The Rear Panel ................11 Touch Screen Display ..............14 Use Built-In Help System ............18 Introduction of EasyWave ............19 Contact SIGLENT ............... 20 SDG2000X Quick Start III...
SIGLENT Adjust the Handle When using the instrument, users can adjust the handle to a needed position which makes it easier to operate and observe. Horizontal Position Carrying Position Figure 1 Adjust the Handle SDG2000X Quick Start 1...
SIGLENT The Front Panel The figure below shows SDG2000X’s front panel composition: 3. Touch Screen Display 4. Numeric Keyboard 5. Knob 2. USB Host 6. Arrow Keys 1. Power Key 11. Menu Keys 8. Channel Select Key 电源键 9. Function Keys 10.
Page 9
SIGLENT of the instrument to the U-Disk. Users can update the firmware through U-Disk. 3. Touch Screen Display SDG2000X has a 4.3 inch TFT-LCD touch screen, which displays current function menu, parameter settings, system state, prompts, etc. It is the most important display and control center of the instrument.
Page 10
SIGLENT position to save a file or choose a file to be read; press the knob to open a selected folder or file. When choosing Waveforms → Page 1/2 → Arb → Arb Type rotate the knob to select a desired built-in or stored waveform. 6.
Page 11
SIGLENT The Output key on the right is used to turn on/off CH2 output. The nominal output impedance of the BNC connector is 50Ω. When pressing Output (the key backlight turns on), the connector outputs waveform according current configuration of CH2. CAUTION: Overvolltage protection of CH1 and CH2 will take effect once any of the following conditions is met.
Page 12
SIGLENT ASK, FSK and PWM modulated signals. It supports “Internal” and “External” modulation sources. The corresponding key backlight will turn on when this function is selected. Sweep ----Sweep This key is used to generate sweeping frequency signals of Sine, Square, Ramp and Arbitrary.
Page 13
SIGLENT function is selected. Parameter ----Parameter Setting Users can switch directly to the parameter setting interface by pressing the key. The corresponding key backlight will turn on when this function is selected. Utility ----Utility Functions and System Settings This key is used to set system parameters and check version information.
Page 14
SIGLENT external U-Disk (D disk) can also be used. The corresponding key backlight will turn on when this function is selected. 10. Waveform Option Waveforms ----Sine Provide sine waveform output which ranges from 1μHz to 100MHz. The backlight of Waveforms will turn on when this function is ...
Page 15
SIGLENT Waveforms ----Ramp Provide ramp waveform output which ranges from 1μHz to 1MHz. The backlight of Waveforms will turn on when this function is selected. “Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, “Phase” and “Symmetry” of the ramp waveform can be adjusted.
Page 16
SIGLENT selected. “Stdev” and “”Mean” of the noise signal can be adjusted. Waveforms ---- Arb Provide arbitrary waveform output which ranges from 1μHz to 20MHz. The backlight of Waveforms will turn on when this function is selected. Support two output modes: “DDS” and “TrueArb”. ...
SIGLENT The Rear Panel Figure 3 SDG2000X Rear Panel 1. Counter BNC connector. The input impedance is 1MΩ. This connector is used to accept the signal measured by the frequency counter. 2. Aux In/Out BNC connector. The function of this connector is determined by the current work mode of the instrument.
Page 18
SIGLENT Sweep/Burst trigger signal output port of internal/manual trigger. Burst gating trigger input port. ASK/FSK external modulation signal input port. Synchronization output port. When synchronization is on, the port can output a CMOS signal with the same frequency as basic waveforms (except Noise and DC), arbitrary waveforms, and modulated waveforms (except external modulation).
Page 19
SIGLENT 4. Earth Terminal Used to ground the instrument. 5. AC Power Supply Input SDG2000X can accept two different types of AC input power. AC power: 100-240V, 50/60Hz or 100-120V, 400Hz Fuse: 1.25A, 250V 6. USB Device Used when connecting the instrument to an external computer to allow waveform editing (such as EasyWave) and remote control.
SIGLENT Touch Screen Display SDG2000X can only display parameters and waveform of one channel at a time. The picture below shows the interface when CH1 chooses AM modulation of sine waveform. The information displayed may vary depending on the function selected. The entire screen of the SDG2000X is a touch screen.
Page 21
SIGLENT 1. Waveform Display Area Shows the currently selected waveform of each channel. The key backlight will turn on when this area of the touch screen is clicked. 2. Channel Status Bar Indicates the selected status and output configuration of the channels.
Page 22
SIGLENT After choosing the parameter to highlight it, use the softkeys, number keys or knob to change the parameter value. High Impedance: display HiZ. Load: display impedance value (the default is 50Ω and the range is 50Ω to 100kΩ). Note: This setting does not actually change the instrument’s output load impedance of 50Ω...
Page 23
SIGLENT of “AM modulation”. After touching the menu on the touch screen to choose the corresponding parameter, use number keys or knob to change the parameter value. 7. Modulation Parameters Area Shows the parameters of the current modulation function. After touching this area of the screen or pressing corresponding menu, use number keys or knob to change the parameter value.
SIGLENT Use Built-In Help System To obtain built-in help information of the product, please press Utility key first, then press Page 1/2 and Help, use the knob to choose the help item you want, finally press Select to obtain help information.
SIGLENT Introduction of EasyWave Arbitrary editing software EasyWave provides 9 standard waveforms: Sine, Square, Ramp, Pulse, ExpRise, ExpFall, Sinc, Noise and DC, which meets most engineers’ basic needs. In addition, it provides several ways of manual drawing, point-to-point line drawing and arbitrary point drawing. EasyWave allows for fast and easy creation of complex waveforms.