Cooper Security EXP-PSU Installation Manual page 9

Smart power supply
Table of Contents

Advertisement

EXP-PSU
Current
Cable Length (Standard 7/0.2 alarm cable)
Drawn
10m
20m
60mA
0.10V
0.19V
80mA
0.13V
0.26V
100mA
0.16V
0.32V
120mA
0.19V
0.38V
140mA
0.22V
0.45V
160mA
0.26V
0.51V
180mA
0.29V
0.58V
200mA
0.32V
0.64V
220mA
0.35V
0.70V
240mA
0.38V
0.79V
260mA
0.42V
0.83V
280mA
0.45V
0.90V
300mA
0.48V
0.96V
320mA
0.51V
1.02V
340mA
0.54V
1.09V
360mA
0.58V
1.15V
380mA
0.61V
1.22V
400mA
0.64V
1.28V
Table 1. Voltage Drop
30m
40m
0.29V
0.38V
0.38V
0.51V
0.48V
0.64V
0.58V
0.79V
0.67V
0.90V
0.77V
1.02V
0.86V
1.15V
0.96V
1.28V
1.06V
1.41V
1.15V
1.54V
1.25V
1.66V
1.34V
1.79V
1.44V
1.92V
1.55V
2.05V
1.63V
2.18V
1.73V
2.30V
1.82V
2.43V
1.92V
2.56V
Figure 4. Connecting Remote Power Supply Units
50m
60m
70m
0.48V
0.58V
0.67V
0.64V
0.79V
0.90V
0.80V
0.96V
1.12V
0.96V
1.15V
1.34V
1.12V
1.34V
1.57V
1.28V
1.54V
1.79V
1.44V
1.73V
2.02V
1.60V
1.92V
2.24V
1.76V
2.11V
2.46V
1.92V
2.30V
2.69V
2.08V
2.50V
2.91V
2.24V
2.69V
3.14V
2.40V
2.88V
3.36V
2.56V
3.07V
3.58V
2.72V
3.26V
3.81V
2.88V
3.46V
4.03V
3.04V
3.65V
4.26V
3.20V
3.84V
4.48V
80m
90m
100m
0.77V
0.86V
0.96V
1.02V
1.15V
1.28V
1.28V
1.44V
1.60V
1.54V
1.74V
1.92V
1.79V
2.02V
2.24V
2.05V
2.30V
2.56V
2.30V
2.59V
2.88V
2.56V
2.88V
3.20V
2.82V
3.17V
3.52V
3.07V
3.46V
3.84V
3.33V
3.74V
4.16V
3.58V
4.03V
4.48V
3.84V
4.32V
4.80V
4.10V
4.61V
5.12V
4.35V
4.90V
5.44V
4.61V
5.18V
5.76V
4.86V
5.47V
6.08V
5.12V
5.76V
6.40V