Download Print this page

GDC ACS-2800 Installation Manual

Automation control system

Advertisement

Quick Links

INSTALLATION MANUAL FOR
ACS-2800 AUTOMATION CONTROL SYSTEM
March 4, 2015

Advertisement

loading

Summary of Contents for GDC ACS-2800

  • Page 1 INSTALLATION MANUAL FOR ACS-2800 AUTOMATION CONTROL SYSTEM March 4, 2015...
  • Page 2 TABLE OF CONTENTS TABLE OF CONTENTS HARDWARE INSTALLATION ..............5 SOFTWARE INSTALLATION ..............12 ADD ACS-2800 CONTROL CUES INTO SERVER ........17 - 2 - INSTALLATION MANUAL FOR March 4, 2015 ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 3 Kec. Grogol Petamburan, Tel: +1 818 972 4370 / Tel: +65 6222 1082 Jakarta Barat 11440 Tel: +51 1 677 6708 +1 877 743 2872 (Toll Free) - 3 - INSTALLATION MANUAL FOR March 4, 2015 ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 4 Marol,Andheri (East), Alvaro Obregon, Mumbai-400 059, India Mexico, D.F., C.P. 01210 Mexico Tel: +81 3 5524 3607 Tel: +91 22 4044 0500 Tel: +52 55 8851 1198/ - 4 - March 4, 2015 INSTALLATION MANUAL FOR ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 5 1.HARDWARE INSTALLATION 1. HARDWARE INSTALLATION Mount ACS-2800 onto the rack using the screws, and connect the Power Cable to the Power Plug . Network port 8 Channels Control LED switches (Connected: Lights on, Disconnected: Lights off) Power Plug On/Off Switch...
  • Page 6 Insert the automation cables into the two slots beneath the FLAT and SCOPE labels and use the safety latch to secure the cable in place. These are used to control Masking. Manual Control LED buttons Connected cable with safety latch secured - 6 - March 4, 2015 INSTALLATION MANUAL FOR ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 7 This yellow-green wire is not in use and should be cut off. Locate the Cinema Switch that controls masking in the projection room: MOVES FORWARD button (SCOPE) MOVES BACKWARD button (FLAT) STOP button - 7 - INSTALLATION MANUAL FOR March 4, 2015 ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 8 SCOPE:Connect the brown and blue wires to the other Masking Control Device. (can connect in any order) Connect the automation cables to control the Dimmer in the hall. Manual Control LED buttons Connected cable with safety latch secured - 8 - March 4, 2015 INSTALLATION MANUAL FOR ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 9 Check the circuitry that controls the Dimmer: Connect the brown wires to the Signal Ports which control Dimmer Up,Middle,and Down Connect the blue wires to the Common Port - 9 - INSTALLATION MANUAL FOR March 4, 2015 ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 10 As well as the Dimmer control, the end of each cable contains blue, brown and yellow-green wires. The yellow-green wire is not used and should be cut off. Locate the Cinema Switch that controls Lighting Switch in the projection room: Hall Lighting Switch - 10 - March 4, 2015 INSTALLATION MANUAL FOR ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 11 If you have extra equipment in the hall you want to control, there are AUX-A and AUX-B you can use. The detail installation procedure is as similar as above. Extra Manual Control LED buttons and Cable Plug - 11 - INSTALLATION MANUAL FOR March 4, 2015 ACS-2800 AUTOMATION CONTROL SYSTEM...
  • Page 12 2. SOFTWARE INSTALLATION Step 1: Install the provided ACS-2800 software to laptop. Double-click on the ACS-2800 IP Software.rar to unzip it and double click on iPad Gataway.msi to install the software. Click on (N)> button to proceed to next step.
  • Page 13 2. SOFTWARE INSTALLATION Click on (C) button to close the installation window. (Click on Windows Update and check whether .NET Framework needs to be updated) Installation of ACS-2800 IP software is completed. - 13 - INSTALLATION MANUAL FOR March 4, 2015...
  • Page 14 2. Click on Start Menu and locate iPad Gateway and double click on it to start application. Click on “Advance” button, it will show the IP address currently assigned to ACS-2800. Default ACS- 2800 IP Address is set at 192.168.3.201.
  • Page 15 Advance Button Existing ACS-2800 IP and MAC Address 3. Input the current existing IP address of the ACS-2800, 192.168.3.201 into the LINK IP section and click on OK. When prompt window "Already link to device!", click on "OK" button. Input 192.168.3.201 and click on OK...
  • Page 16 2. SOFTWARE INSTALLATION 4. Amend the existing IP Address of ACS-2800 to the current IP Address range used in the Cinema, and click on OK. User needs to assign and set both IP Address and Gateway and click on the "OK"...
  • Page 17 3. ADD ACS-2800 CONTROL CUES INTO SERVER 3. ADD ACS-2800 CONTROL CUES INTO SERVER 1. From GDC server’s SMS GUI, click on “Configuration” , use “Maintenance” to login, password is ”257910” 2. Locate “General” tab,click on “Automation” button, then choose “Devices” tab.
  • Page 18 3. ADD ACS-2800 CONTROL CUES INTO SERVER 3. Click on “Add” button to create a new device. 4. Edit The name as “ACS-2800”, and choose the Type as “NETWORKSOCKET”, click on “OK” to save this device. - 18 - March 4, 2015...
  • Page 19 3. ADD ACS-2800 CONTROL CUES INTO SERVER 5. A new ACS-2800 will exist in the Device Name, edit related imformation of ACS-2800 as below : IP Address, Port Number “10003”, choose the Transport Protocol “TCP”, then click on “Edit Control Cues”...
  • Page 20 3. ADD ACS-2800 CONTROL CUES INTO SERVER 6. In the “Edit Control Cues” GUI, click on “Add” to edit 8 channels control cues, e.g. “1_On” means channel 1 switch connect, “1_Off” means channel 1 swith disconnect, “1_Trigger” means channel 1 switch connect for one second then disconnect.
  • Page 21 3. ADD ACS-2800 CONTROL CUES INTO SERVER Complete setting list as below: name="1_On" value="0x55 0xbb 0x4 0x0 0x0 0x1 0x0 0x01 0x01 0xff" name="1_Off" value="0x55 0xbb 0x4 0x0 0x0 0x1 0x0 0x01 0x01 0x0" name="1_Trigger" value="0x55 0xbb 0x4 0x0 0x0 0x4 0x0 0x1 0xff 0x0a 0x0"...
  • Page 22 7. Use the “Actions” tab to add a new Event label. Add a new action to the Event label, and select ACS-2800 for that action, choose the correct control cue for that action. e.g. add “Flat” action label, select “ACS-2800” for the device, choose “1_Trigger” for the action.
  • Page 23 Cert. No. CN09/32221 GDC Technology manufacturing facility is ISO 9001:2008 certified. Copyright © 2015 GDC Technology Limited. All rights reserved. All trademarks listed in this manual are properties of their respective owners. Specifications are subject to change without notice due to ongoing product development and improvement.