Resolution Products Wireless Translator RE208 Instructions

Hardwire-to-honeywell

Advertisement

Quick Links

Wireless
Security
Solutions
®
RE208 Hardwire-to-Honeywell
Wireless Translator™
Features
• Converts hardwire zones into Honeywell-compatible wireless signals.
• 8 Hardwire loops with end-of-line resistor detection.
• Unique wireless ID for each zone, plus 1 for main device.
• Transmit diversity for long reliable range.
• PIR powering (via external supply).
• 3 year operation on batteries (contacts only).
• Complete supervision of zone tampers and low battery.
Key Instructions
• Use with normally closed contacts in-line with 4.7 K-ohms end-of-line resistors.
• Not for use with life safety devices, such as Smoke or CO sensors.
• External supply requirements (wall-AC): 12V DC at least 50 mA.
• PIR & Glassbreak (powered devices) usage:
4-wire devices only. Not for use with 2-wire powered devices.
2 AA back-up batteries will drive contacts only, and cannot drive a PIR.
Under external supply failure, the PIR/Glass would likely alarm.
If using PIR/Glass, we recommend using 12V DC, 24-hour back-up supply.
If using old panel 12V DC supply, verify operation and old battery.
• Enrolling:
Hardwire zones (labeled "Loops" on the circuit board terminals):
• Hardwire zones are enrolled into Honeywell system using the RF Learning
tripping enrollment mode.
• Input Type: 3 (Supervised RF), Loop: 2
• When prompted, open/close each zone twice
(fault/restore/fault/restore) to enroll the serial number.
Translator itself. Trouble supervision of the Translator itself is recommended;
Assign the Translator to a zone for sending check-in supervisories, cover
tamper and low battery.
• Zone Type: 8 (24 hour Aux) – When cover opened: "fault" when system
not armed, "alarm" when armed.
• Input Type: 3 (Supervised RF), Loop: 4
• When prompted, toggle the tamper switch to enroll the serial number.
Operation
• 8 Hardwire 4.7K-ohm Zones – transmit 8 unique wireless IDs:
Alarm on open circuit. Tamper on short circuit.
Supervisories, every hour for each zone.
RE208_Hardwire_to_Honeywell-Compat_Translator.doc
Page 1 of 4
www.ResolutionProducts.com
5/25/2011
• Translator Main Zone wireless transmission (9
Tamper, when cover opened.
Low battery, when either low AA batteries, OR loss of 12V DC external.
Supervisory every hour.
• How ID's work: If the Translator Main Zone is XXX-YYY0, then the Zone 1's ID is
XXX-YYY1, and Zone 2's ID is XXX-YYY2, etc.
• LED Operation
Green LED: On if AC power present.
Red LED:
When 12V DC is present: "Blinks" on transmit to panel;
"on" if device tamper or device low battery.
• Application Diagram
Existing Hardwire Sensors
Old Hardwire Panel Mounted
• Connection Diagram
Contact
Closed Normally
Open in Alarm
4.7K
To Enroll zone,
perform 2 open/close
sequences
RE208_Hardwire_to_Honeywell-Compat_Translator.doc
Page 2 of 4
www.ResolutionProducts.com
th
unique ID):
New System's wireless
language
New Wireless
System
New
Self-Contained System in
public area
in utility area
AA Backup
batteries will NOT
power PIR
PIR
12V DC
Loop
x
5/25/2011

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wireless Translator RE208 and is the answer not in the manual?

Questions and answers

Summary of Contents for Resolution Products Wireless Translator RE208

  • Page 1 Wireless • Translator Main Zone wireless transmission (9 unique ID): Security Tamper, when cover opened. Solutions Low battery, when either low AA batteries, OR loss of 12V DC external. Supervisory every hour. ® RE208 Hardwire-to-Honeywell Wireless Translator™ • How ID’s work: If the Translator Main Zone is XXX-YYY0, then the Zone 1’s ID is XXX-YYY1, and Zone 2’s ID is XXX-YYY2, etc.
  • Page 2 Talks to SAW receivers. Zone sensing duration: State sensed if held more than 600ms. Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. End-of-line Resistors: 4.7k-ohm, 5%. However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell or DSC.