Legal and Safety Information Legal and Safety Information Thank you for purchasing Selectronic Select.live remote monitoring device for the SP PRO series I and II inverters. This document, copyright of Selectronic Australia is intended to be used for the installation and operation of Select.live.
Setup Wizard of Select.live .................. 15 4.4.1 Configuring Select.live for the SP PRO .................... 16 4.4.2 Configuring Select.live for the Internet via Wi-Fi ................17 4.4.3 Configuring Select.live to the Internet via Ethernet ................18 4.4.4 Connection to the Ethernet cable ....................19 4.4.5...
Page 4
Delete the system from Portal ....................... 56 Changing my Profile ................... 56 8.6.1 Changing My Details ........................57 8.6.2 Changing Password ........................57 Maintenance and Service ..............58 Troubleshooting ................. 59 Specifications ..................61 Select.live ......................61 Contact ....................62 OI0009 Revision 01 Select.live User Manual...
(Order code 005283) for SP PRO series II and for the SP PRO Series I. When installing Select.live with SP PRO series I, the Adaptor Kit (Order code 005290) is also required. This document doesn’t provide any detailed information about the SP PRO. For detailed information on the SP PRO, download relevant documents from www.selectronic.com.au.
Example Example in italics Select.live Select.live is a remote communication system for the SP PRO that enables users to view data remotely using internet connected PC, laptop and mobile devices. Select.live consists of two modules, Select.live and Select.live portal Select.live communicates with the SP PRO system via its communication port and sends the data to the remote server (Select.live Portal) via the internet.
Communication Cable Wall Mount Screws with wall anchors Double Side Mounting Strip Small Screw Select.live Adaptor Kit Package This extra package is required when connecting Select.live to the SP PRO Series I inverter. Order Code: 005290 Position Quantity Description 12V DC power adaptor...
Selectronic Australia Select.live Overview 3 Select.live Overview Select.live Position Description Wi-Fi antenna area of Select.live LCD display of Select.live Position for the small screw to secure Select.live to the wall mount plate OI0009 Revision 01 Select.live User Manual...
Select.live Overview Selectronic Australia Device Label The device label is found on the back of Select.live. The label has following details Position Label Description WLAN MAC MAC address of the Wi-Fi. ETH MAC MAC address of the Ethernet. Serial Number.
Selectronic Australia Select.live Overview Connection and LED indicators The connection area is on the back of Select.live facing downwards. The label for the connectors is on the back. Position Name Status Description Power LED Solid Red Select.live has a power supply Select.live has no power supply...
Installation and Commissioning Selectronic Australia 4 Installation and Commissioning Based on the network selection, there are two options for the commissioning of Select.live. Choose the method of connection that is most convenient for the installation. • Commission of Select.live via Wi-Fi connection •...
If using Ethernet to connect Select.live to the internet, the maximum length of the Ethernet cable is 100m. • If using Wi-Fi to connect Select.live to the internet, Select.live must be mounted in a location with access to your Wi-Fi network. •...
Connection to the SP PRO 4.2.1 Connection to the SP PRO Series II • Connect Select.live to the SP PRO Series II using the Communication Cable supplied, as shown. • Select.live is powered from the SP PRO. The power adaptor is not required.
Installation and Commissioning 4.2.2 Connection to the SP PRO Series I • Connect Select.live to the SP PRO Series I using the Communication Cable and the Powered Console cable supplied, as shown. • The Powered Console Cable threads though the gland and sleeve provided through the base of the SP PRO.
Check that the power LED and LCD display are lit after the connecting power to the SP PRO (and power adaptor for SP PRO series I). After a minute, the following message will be displayed on the LCD display of Select.live: ------ SETUP -------...
4.4.1 Configuring Select.live for the SP PRO • Select.live autodetects the SP PRO. The SP PRO details are shown in the dialog box as shown. Click [Next] to proceed to the next step of the Setup Wizard- Selection of the network.
Installation and Commissioning Selectronic Australia 4.4.2 Configuring Select.live for the Internet via Wi-Fi • Select the <Connection Type> as “Wi-Fi” and click [Next] to continue as shown. • A form for the Wi-Fi connection appears as shown. • Click [Refresh] to update the list of Wi-Fi networks available in the <Available Access Points>.
Selectronic Australia Installation and Commissioning 4.4.3 Configuring Select.live to the Internet via Ethernet • Select the <Connection Type> as “Ethernet” and click [Next] to continue. • A form for the Ethernet connection appears as shown. • With <DHCP Enabled> as “On”, enter the <Hostname> (can be any name or empty) only.
4.4.4 Connection to the Ethernet cable If you are connecting Select.live to the internet via Ethernet then connect the Ethernet cable between Select.live and the router now. The maximum length of the ethernet cable is 100m of CAT5e or better.
Installation and Commissioning 4.4.5 Completing the Setup Wizard • Select.live is ready to link in the Portal with “Device ID” and “Serial”. • Within 30 seconds, “Device ID” and “Serial” are also shown in LCD display of Select.live as shown:...
• Browse to Select.live Portal Registration page https://select.live/register. The Registration form appears in the browser as shown: • An alternate way to reach registration page is to browse to Select.live Portal, https://select.live and click on [Not registered yet?”] • Fill the form by entering <Full Name>, <Email>, <Password>, <Repeat Password>, <Mobile Number>, <Number and Street>, <Street line 2>, <City or Suburb>,...
• The Registration is complete and ready to login. Link Select.live to the Portal • Browse to the login page at https://select.live. A login form appears: • Fill in the <Email> and <Password> and click [Login] • On Successful login, the page redirects to System page as shown.
Page 23
Selectronic Australia • Click on [Add a System]. • Fill in the form by entering <Device ID> and <Serial> of your Select.live. • If you are the owner of the system then leave <Access Required> as Owner. • If you are the installer and wish to add this system to your profile then you will need o Check that the owner of the system has first added the system to their profile.
Select.live is successfully added to Select.live Portal. Monitoring of the system Following are the pages of Select.live Portal for the monitoring of the system. • System Page: This is the home page where all the systems are listed and a new system can be added.
Selectronic Australia 5 Select.live Display Operation Select.live has an LCD display that helps in the setup of the device and displays SP PRO data. Depending on the device setup, the LCD display changes the screen. Following are the screens that are displayed on the LCD display of the device.
Page 26
The screen switches between Screen 1 and Screen 2 every 2 seconds. The backlight of the LCD display stays off. Note: if the SP PRO has an active event, the screen is overridden by the event screen as shown in Section 5.4 (page 28). OI0009 Revision 01 Select.live User Manual...
** No Connection! ** Please check you Wi-Fi password or Ethernet connection Note: if the SP PRO has an active event, the screen is overridden by the event screen as shown in Section 5.4 (page 28). OI0009 Revision 01 Select.live User Manual...
PC or mobile device from the same network. Following is the procedure to login to the web interface of the device • After the Setup Wizard, the <IP address> of Select.live is displayed on the LCD screen as shown. --- SP PRO Status --- CLOUD :OK :192.168.43.130...
Selectronic Australia Select.live Operation 7 Select.live Operation User Interface Select.live is operated via its web interface. After login, the web interface is displayed as shown. Position Description Logo Content. On Click, navigates to Setup Wizard page Menu navigation. • Setup Wizard – navigates to the Setup Wizard page (see page 31) •...
Rating – Power rating of the connected SP PRO in kW unit. E.g. 3.0kW • Serial – Serial number of the connected SP PRO • Connection Status – Connection status of SP PRO (Offline or Online) OI0009 Revision 01 Select.live User Manual...
[Details] – Shows the detailed information of the connected SP PRO (see page 34) o [Delete] – remote the connected SP PRO (see page 34) [New SP PRO] button – Open a form to add new SP PRO (See page 35) OI0009 Revision 01 Select.live User Manual...
Page 33
[Download Firmware] – on click, download new firmware and changes button to [Cancel Download] during download and [Install Firmware Update] after download o [Install Firmware Update] – On click install the firmware and reboots. OI0009 Revision 01 Select.live User Manual...
Deleting the connected SP PRO • Login to the device (see page 15) • Click on ‘Advanced Settings’ in the upper right corner. • Click on [Delete] in the SP PRO table. Note: This action is not reversible OI0009 Revision 01 Select.live User Manual...
Submits form. On successful – add new SP PRO and closes. On fail – pops an error message. On click – closes the dialog box • Change <SP PRO login password> if it is different than “Selectronic SP PRO” • Click [Autodetect]→[Create]. •...
Selectronic Australia Select.live Operation Editing Wi-Fi Connection • Login into the device (see page 15) • Click on ‘Advanced Settings’ in the upper right corner. • Click on [Edit] of Wi-Fi from my Network table. OI0009 Revision 01 Select.live User Manual...
Page 37
<Encryption> Wi-Fi network’s password type. “none”, “WEP”, “WPA” and “WPA2” <Password> SP PRO login password. Defaults to “Selectronic SP PRO” [Update] Submits form. On successful – updates the Wi-Fi connection and close the dialog box. Note: only update of change but not applied yet [Cancel] On click –...
Select.live Operation Editing Ethernet Connection • Login into the device (see page 15) • Click on ‘Advanced Settings’ in the upper right corner. • Click on [Edit] of the Ethernet in the ‘My Network’ table. OI0009 Revision 01 Select.live User Manual...
Page 39
Click [Update] to update changes • Click [Apply Network Changes] from Advanced Setting Page to apply changes. Ethernet connection is successfully changed. Note: This will override the network method preference. Ethernet will be preferred over Wi-Fi. OI0009 Revision 01 Select.live User Manual...
Selectronic Australia Select.live Operation Updating new Firmware Select.live checks for new firmware daily at midnight and will be updated within the following 4 hours. The device can be forced to check for new firmware and update via the web interface.
On release of the button, the device factory resets and reboots. A short press of the button, less than 5 seconds, will reboot Select.live only. For confirmation of the factory reset, after Select.live reboots, the LCD display shows the initial setup screen (see page 25).
Selectronic Australia Select.live Operation Login to the Portal • Browse the login page at https://select.live. A login form appears as shown. Parameter Description <Email> Email of the user <Password> Password of the user [Login] Submits form. On successful – logins into the account and redirect to System page.
Select.live Operation Selectronic Australia Reset the login password • Browse the Forget Password page by the link http://select.live/forgot. A forgot form appears as shown. Parameter Description <Email> Email of the user <Mobile Number> Mobile Number of the user [Send] Submits form. On successful – a randomly generated password is sent to the email.
Purchased - latest Total Grid Import Energy of the system in kWh • Consumption – latest Total Load Energy of the system in kWh [Add a System] button – Opens a form to add new System OI0009 Revision 01 Select.live User Manual...
My Profile – navigates to My Profile page (see page 56) • Logout – On click, logout from the portal and redirect to Login page Main Content. This content changes depending on the pages selected. OI0009 Revision 01 Select.live User Manual...
ECO – shows the number of C0 avoided comparing different state (see page 51) Energy Chart – shows the bar and line combo chart of historical solar, load and grid energy. (see page 52) OI0009 Revision 01 Select.live User Manual...
Depending upon the system type, the power flow icons will vary. Off-grid System On-grid with generator backup System On-grid System OI0009 Revision 01 Select.live User Manual...
Page 48
This week Grid Import energy • This week Grid Export energy • This month Grid Import energy • This month Grid Export energy • This year Grid Import energy • This year Grid Export energy OI0009 Revision 01 Select.live User Manual...
Page 49
Today Load energy • This week Load energy • This month Load energy • This year Load energy The Offline message is shown if the last update received is more than 20 minutes old. OI0009 Revision 01 Select.live User Manual...
INFO shows the connected SP PRO detail. NOTE: For Advanced Multiphase systems (Three phase and split phase) the SP PRO serial and SP PRO Rating is for the primary (L1 phase) SP PRO only. OI0009 Revision 01 Select.live User Manual...
The last data received from the system is less than 20 minutes old and has active events. The last data received from the system is more than 20 minutes old, regardless of active events. 8.3.5 ECO The amount of C0 emissions avoided by having your system. OI0009 Revision 01 Select.live User Manual...
Bar chart shows date and time versus use and production of energy. The line chart shows the battery SoC at that time. NOTE: Clicking on the chart legend will turn on and off the display of that parameter within the graph. OI0009 Revision 01 Select.live User Manual...
Page 53
Right Average state of charge in % (SoC) over interval. Date and time The interval is from 1 hour to 1 month depending upon the date range selected. OI0009 Revision 01 Select.live User Manual...
This status icon means that the event is not active and has cleared. This status icon means that the event is active and event type is Informative only This status icon means that the event is active and event type is a system fault. OI0009 Revision 01 Select.live User Manual...
Can be dragged to update location. [Save] Save the updated location of the system. [Reset] Reset to original location before [Save] [Delete System] Delete the system and its data with confirmation (see page 56) OI0009 Revision 01 Select.live User Manual...
• On click [Delete], the system is removed and data are deleted permanently. The portal redirects to Systems page • Select.live can be linked to the different account. Changing my Profile • Login into the portal (see page 42) •...
8.6.2 Changing Password • Enter <Old Password> • Enter <New Password> • Enter <Re-type Password> • Click [Save] to change the password. On success, changes password with message “Password updated!” OI0009 Revision 01 Select.live User Manual...
Selectronic Australia Maintenance and Service 9 Maintenance and Service Select.live has an IP rating of IP43 and is not waterproof. Regular maintenance is required. • Regularly conduct visual inspections of Select.live for external damage, dirt, moisture and insects. • Protect Select.live from wet conditions. Ingress of liquids may damage or destroy Select.live.
ON. Entered Wi-Fi SSID and Factory reset Select.live to reset the Wi-Fi password in the Setup Wizard connection and use the Setup Wizard are wrong again with Wi-Fi SSID and password.
Page 60
Setup Wizard the device again. (See page 41 and 15) “** No Connection! If Wi-Fi used for network Factory reset Select.live to reset the Wi-Fi Please check your connection, the entered Wi-Fi connection and use the Setup Wizard SSID and password in the again with Wi-Fi SSID and password.
Network Time administrator that these outbound ports are open). Power Supply Power Method DC adaptor or supplied Communication Cable (Power over serial) Rating 6V to 24V, 1A Max, 0.2A (Avg), 2W OI0009 Revision 01 Select.live User Manual...
Selectronic Australia Contact 12 Contact If you have any technical issues regarding Select.live, contact Selectronic Support at www.selectronic.com.au/support/ Please include the following information in order to receive faster assistance: • The Serial number, firmware version of Select.live • The Serial number of the SP PRO.