OVERVIEW OF THE LPR-1DHP SYSTEM ..............9 Data sheet of LPR-1DHP Station ................10 Opening angle LPR-1DHP station ................10 Mounting position of the LPR-1DHP stations ............11 COMPONENT SETUP OF THE LPR-1DHP STATION ..........12 Overview ........................12 Front element ......................13 3.2.1 LED display .......................
Page 3
MOUNTING ......................17 COMMISSIONING LPR-1DHP WITH TCP/IP INTERFACE ........18 Requirements ......................18 Connection to LPR-1DHP Station ................18 WEB SERVER FOR LPR-1DHP UNITS WITH TCP/IP INTERFACE ......20 Open Web Server ....................20 Settings........................21 7.2.1 „LAN“ area ........................ 22 7.2.2 „Network“...
Page 5
SYMEO Local Positioning Radar System LPR-1DHP Product Documentation The documentation for the LPR-1DHP Local Positioning Radar System is published by: SYMEO GmbH Prof.-Messerschmitt-Str. 3 D-85579 Neubiberg www.symeo.de If you have any questions or suggestions, please contact: Email: info@symeo.com phone: +49 89 660 7796 0 Copyright ...
SYMEO Local Positioning Radar System LPR-1DHP Product Documentation Overview Safety Safety Instructions LPR systems are purely tracking and assistance systems. They therefore do not satisfy the safety class 3 requirements and must not be used as standalone systems in safety-critical applications, such as automation or anti-collision.
Do not use any damaged wires (damaged insulation, exposed wires). A faulty wire poses a risk of electric shock or fire hazard. Polarity reversal or otherwise faulty connection can damage the LPR- 1DHP station. In that case the station must be send to the SYMEO service. Setup and Operation During installation, make sure that no objects or fluids enter the device (risk of electric shock, short circuit).
The warranty shall be voided if you cause defects to the device by installing or exchanging system extensions. Additional Instructions Regarding LPR-1DHP station The LPR 1 DHP station must not be opened except for installation and mounting. The LPR 1DHP station contains no serviceable components.
Product Documentation Overview of the LPR-1DHP system An LPR-1DHP system consists of two units named BS and TS that conduct the measurements. One unit (BS) initiates the measurement and the second unit (TS) replies. Both units are shipped in a pre-configured set. Unit BS1 is configured to measure with TS1, BS2 with TS2 and so on.
Symeo LPR-1D protocol Antenna integrated Compliance FCC (Part 15.255) Depending on the application conditions Opening angle LPR-1DHP station The LPR-1DHP station has an integrated antenna with +/-2° opening angle. LPR 1DHP Station Integrated antenna -3 dB -3 dB 4° 4°...
SYMEO Local Positioning Radar System LPR-1DHP Product Documentation Mounting position of the LPR-1DHP stations The stations must be aligned with each other for proper measurement. In addition the following topics must be considered: Site-specific mounting instructions must be followed when available.
Product Documentation Component setup of the LPR-1DHP station Overview The LPR-1DHP station consists of front element A, rear element B and mounting bracket C as shown in Figure 3. Figure 3: System components front element A, rear element B and mounting bracket C...
The rear element (B) carries the front element (A) and is mounted in the mounting bracket (C). 3.3.1 LPR-1DHP station with TCP/IP interface The rear element of the LPR-1DHP station with TCP/IP interface provides the following connections (see Figure 5): ...
Mount the LPR-1DHP station in the mounting bracket (C). When tightening the screws in the mounting slot (C1) make sure that you can still align the system unit.
Data link has been established over TCP/IP. Once these prerequisites have been fulfilled, you can connect the station to the network and commission the LPR-1DHP system. How to do this is explained in the following chapters. Connection to LPR-1DHP Station With delivery the LPR-1DHP stations have the fixed IP-Address 192.168.1.99, if no other IP-Address is labeled outside the LPR-1DHP...
Page 19
1. Push the Windows Start Button 2. Choose Run 3. Enter cmd and click OK 4. Enter in the cmd.exe window: ping 192.168.1.99 or the IP-address of the LPR-1DHP station. Figure 9 – Ping LPR-1DHP Station The LPR-1DHP Station should answer with a Reply.
Web Server for LPR-1DHP units with TCP/IP interface Having a LPR-1DHP station with TCP/IP interface the network settings for this station are described in this chapter. Therefore it is necessary to open a TCP/IP connection between your computer and the LPR- 1DHP station.
7.2.5. Special Functions: See chapter 7.2.6. Press button Upload changes to accept the changes of the LPR-1DHP station. Press button Reboot System to reboot the LPR-1DHP station with the new settings. „LAN“ area 7.2.1 MAC- Unique hardware address of the LPR-1DHP station on the LAN (Ethernet...
SYMEO Local Positioning Radar System LPR-1DHP Product Documentation If the LPR-1DHP station is set to „DHCP“ but does not receive an IP-address from the DHCP server within 60 sec after the reboot the last applied fixed IP-address is used. Change A button is labeled "DHCP"...
(Binary Port, default: 3046) For each port, select the connection type between the LPR-1DHP station and PC, SPS, S7 from the Connection Type list. By default, both ports (ttyS2, ttyS3) are disabled. Due to the selected connection type, different input masks are visible which are explained below.
The port number is not editable. See also section "Extended system access". HTTP Click this checkbox to permit or forbid accesses to the LPR-1DHP station's Web server via HTTP (unencrypted transmission) (checked: accesses are allowed). You must also enter the corresponding port number as appropriate.
LPR-1DHP Product Documentation manufacturer. User User ID for access to the TCP/IP port. It has been set to "symeo" by the manufacturer and cannot be changed. Password Enter the new password here if you want to change the password. The password has been set to "54all2u"...
7.2.7 Accept settings / System Reboot As described in chapter 7.2 it is necessary to transmit the changes to the LPR-1DHP station and afterwards reboot the station. Press button „Upload changes“ to load the changes.
If Connection Type „TCP - Listening on Data Port“ (ttyS2) is enabled this table shows further connection information. Proto: Protocol (TCP, UDP) Recv-Q: Number of buffered Bytes, which are received from the LPR-1DHP station Send-Q: Number of buffered Bytes, which the LPR-1DHP station should send Local-Address: LPR-1DHP Interface address (0.0.0.0 – listening to all interfaces)
Of Connection Type „TCP - Listening on Data Port“ (ttyS2) is enabled this table shows further connection information. Proto: Protocol (TCP, UDP) Recv-Q: Number of buffered Bytes, which are received from the LPR-1DHP station Send-Q: Number of buffered Bytes, which the LPR-1DHP station should send Local-Address: LPR-1DHP Interface address (192.168.1.99) with port (3045) Foreign Address: IP-address of opposite station (192.168.1.1) with port (1333)
Step 1 – File system 7.5.1 It is possible to make a copy of the actual firmware by downloading the firmware from the LPR-1DHP station. Click the button „Backup ramdisk.gz“. Click the "Browse" button in the "Step 1 – flash ramdisk.gz" area.
Protocol XP Description for TCP/IP and RS232 General Description This protocol is the interface between a LPR-1DHP station and the user. The binary protocol XP protocol provides information in high density. Its structure ensures a simple implementation. The transfer is done in single data frames.
The CRC-calculation is only applied to the original symbols. The appropriate calculation for coding must applied before byte stuffing. If receiving the data from the LPR-1DHP system the byte stuffing must be resolved to get the original symbol. Then the CRC is updated with the original symbol.
END field) are replaced (see chapter 8.1.2.) Byte stuffing causes a different protocol length. For the fixed frame protocol each LPR-1DHP data packet is filled up with zero bytes to a fixed length of bytes (i.e. 87 bytes) before the data packet is sent. Byte stuffing does not occur.
SYMEO Local Positioning Radar System LPR-1DHP Product Documentation converter either the connection to a port on the LPR has to be initialized from the PC or the LPR unit is establishing a connection to a PC. If the connection is established, the PC has to read the data from the LPR in fixed data length (i.e.