Motorline professional TEC100 User& Installer's Manual
Motorline professional TEC100 User& Installer's Manual

Motorline professional TEC100 User& Installer's Manual

Hide thumbs Also See for TEC100:

Advertisement

Quick Links

EN
TEC100
USER/INSTALLER MANUAL
V3.0
REV. 01/2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TEC100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Motorline professional TEC100

  • Page 1 TEC100 USER/INSTALLER MANUAL V3.0 REV. 01/2019...
  • Page 2: Table Of Contents

    00. CONTENT 01. SAFETY INSTRUCTIONS INDEX STANDARDS TO FOLLOW ATTENTION: 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT This product is certified in accordance with European Community PRODUCT PROFILE (EC) safety standards. TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT INSTALLATION This product complies with Directive 2011/65/EU of the European Parliament and of the Council, of 8 June 2011, on the restriction of 04.
  • Page 3: Safety Instructions

    01. SAFETY INSTRUCTIONS 02. PRODUCT STANDARDS TO FOLLOW PRODUCT PROFILE • It is important for your safety that these instructions are followed. The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It •...
  • Page 4: Installation

    1 • Apply the drilling diagram (B) to the 2 • Make the holes: 5 • Insert the cable into the hole. 6 • Attach the body of the TEC100 to the desired installation place. F - TEC100 fixing holes;...
  • Page 5: Programming

    04. PROGRAMMING 05. DETAILED PROGRAMMING GUIDE QUICK REFERENCE PROGRAMMING GUIDE USER SETTINGS Master code Master code To enter the programming mode To enter the programming mode 999999 is the default factory master code 999999 is the default factory master code To exit from the programming To exit from the programming mode...
  • Page 6 05. DETAILED PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE USER SETTINGS USER SETTINGS Add the card as for a card user To add a card user (Method 1) Read card To Add a card and Pin user Press to exit from the programming mode This is the fastest way to enter (The PIN is any four digits Then allocate the card a PIN as follows:...
  • Page 7: Door Settings 6A

    05. DETAILED PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE DOOR SETTINGS DOOR SETTINGS Relay Output Delay Time To remove the alarm master code value To reset the Door Forced Open Read valid card Master Code To set door relay strike time warning 0-99 is to set the door relay time 0-99 seconds Read valid card...
  • Page 8: Access Control Through Code (Mca) 7A

    ACCESS CONTROL THROUGH CODE (MCA) When to Use When there is an MCA connected with a TEC100 to operate only with code, we need to follow the following steps to register inputs and outputs. 1 • Access "Operation" and select the "tools"...
  • Page 9 05. DETAILED PROGRAMMING GUIDE 05. DETAILED PROGRAMMING GUIDE ACCESS CONTROL THROUGH CODE (MCA) ACCESS CONTROL THROUGH CODE (MCA) 6 • Access "Configuration" and select the "Personnel" tab. 9 • Select the user you want to give privilege and click on "Access Privilege". 10 •...
  • Page 10: Acousto-Optic Instructions

    06. ACOUSTO-OPTIC INSTRUCTIONS 07. CABLING SOUNDS AND LIGHTS LEAD WIRE DESCRIPTION OPERATION STATE RED LIGHT GREEN LIGHT BUZZER NOTE Line Marks Color Function description sequence Standby Slow flashing BELL_A Pink Doorbell button one end Buttons BELL_B Light pink The doorbell button to the other end Success Di—...
  • Page 11: Cabling Diagram

    07. CABLING CABLING DIAGRAM Ordinary power supply cabling diagram Access control power supply cabling diagram Operating as a wiegand output reader In this mode the unit supports a wiegand 26 bit output so the wiegand data lines can be connected to any controller supports 26 bit input.

Table of Contents