Tx Ports: Slot 1 And 2: 10/100/1000 Mbit/S, Slot 3: 10/100 Mbit/S - ABB NE840 User Manual

800xa networks
Table of Contents

Advertisement

Section 2 Interface specifications

TX Ports: Slot 1 and 2: 10/100/1000 Mbit/s, Slot 3: 10/100 Mbit/s

Ethernet TX
Electrical specification
Data rate
Duplex
Circuit type
Transmission range
Isolation to
Connection
Shielded cable
Conductive housing
* Note: Railway installation close to the rails. To minimise the risk of interference, a shielded cable is recommended when
the cable is located inside 3 m boundary to the rails and connected to this port. The cable shield should be properly
connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance
connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive
enclosure should be connected to the earthing system of an installation and may be directly connected to the
functional earth. Refer also to
3BSE080639
Slot 3
12
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
13
10/100 Mbit/s, TX port
14
10/100 Mbit/s, TX port
15
10/100 Mbit/s, TX port
16
10/100 Mbit/s, TX port
17
10/100 Mbit/s, TX port
18
10/100 Mbit/s, TX port
19
IEEE std 802.3. 2005 Edition
Slot 1 and 2: 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Slot 3: 10 Mbit/s, 100 Mbit/s manual or auto
Full or half, manual or auto
TNV-1
Up to 150 m with CAT5e cable or better
All other
RJ-45 auto MDI/MDI-X
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to
rails*
Yes