loading
Need help?

Need help?

Do you have a question about the CR3HV-F and is the answer not in the manual?

Questions and answers

Summary of Contents for Hussmann Chino CR3HV-F

  • Page 1 /CHINO Installation & Operation R3HV (CR3HV)-M/F Manual COMBINATION SERVICE AND SELF-SERVICE MEAT/FISH CASE REV. 0217...
  • Page 2: Table Of Contents

    Defrost Data ..................14 material. If a shortage should exist and is found to be the Physical Data ..................14 responsibility of Hussmann Chino, notify Hussmann Chino. Glycol Requirements ................14 If such a shortage involves the carrier, notify the carrier Electrical................
  • Page 3: Cut And Plan Views

    Cut and Plan Views...
  • Page 4: Installation

    Installation LEVELING: ALL CASES WERE LEVELED AND JOINED WHERE NECESSARY PRIOR TO SHIPMENT TO ENSURE THE CLOSEST POSSIBLE FIT WHEN CASES ARE JOINED IN THE FIELD. WHEN JOINING, USE A CARPENTERS LEVEL AND SHIM LEGS ACCORDINGLY. CASES MUST BE RAISED CORRECTLY: LIFT UNDER IMPORTANT INFORMATION LEGS OR WOOD LEG BRACES WHERE SUPPORT IS...
  • Page 5 Installation (Cont'd) 5. Apply liberal beads of case joint sealant (butyl) to 7. To compress the sealant at the joints, use two the areas (solid dark lines) shown in the diagram Jurgenson ® or similar hand screw type wood below (Fig.2, #1) of the fi rst case. clamps.
  • Page 6: Glass Installation/Balancing

    Installation (Cont'd) Glass Installation/Balancing Glass Adjustment The top cylinders, which allow the raising and lowering of the glass, have been carefully tested for proper tension. However, during shipment, the lubricant inside may have settled. This settling may cause excessive or uneven tension on the glass - to the point of breakage.
  • Page 7: R3Hv Glass Alignment Field Instructions

    Installation (Cont'd) R3HV Glass Alignment Field Instructions These fi eld instructions have been developed to help resolve a glass alignment issue with R3HV cases in the fi eld. Figure #1 will show how the glass should be level when touching the front rail of the case in the middle section. If glass is misaligned then on the end of the case, where it meets the front rail, the glass could be higher.
  • Page 8 Installation (Cont'd) The following is the sequence of steps that should be taken to correct glass misalignment issues; Step 1 Figure #3 will show Step 1 procedures. • Always check to see if case has been leveled properly • Ensure that the middle case bullet feet are touching the fl oor •...
  • Page 9 Installation (Cont'd) Step 3 Figure #5 will show Step 3 procedures. • Loosen bolt in raceway to allow arm freedom to move • Bolt size is 8mm x 50mm Step 4 Figure #6 will show Step 4 procedures. • Remove rear cap from rear of case •...
  • Page 10 Installation (Cont'd) Step 5 Figure #7 will show Step 5 procedures. v BEFORE BEGINNING NEXT STEP ENSURE THERE ARE TWO PEOPLE AVAILABLE TO DO WORK • Lift front glass and open until glass is at full extension • Once glass is fully extended gently push the glass clamp assembly •...
  • Page 11: Joint Trim

    Installation (Cont'd) Joint Trim DO NOT SEAL JOINT TRIM OR SPLASHGUARDS TO THE FLOOR! After cases have been leveled and joined, and refrigeration, electrical, and waste piping work completed, install the splashguards and joint trim where necessary. Fasten the splash guards along the top edge, or center, with 3/8" long sheet metal screws.
  • Page 12: Plumbing

    Plumbing Waste Outlet and P-TRAP 3. Always provide as much down hill slope ("fall") as The waste outlet is located off the center of the case on possible; 1/8" per foot is the preferred minimum. one side allowing drip piping to be run lengthwise under PVC pipe, when used, must be supported to the fi...
  • Page 13: Refrigeration

    Refrigeration Piping Expansion Valve Adjustment The refrigerant line outlets are located under the case. Expansion valves must be adjusted to fully feed the Locate fi rst the electrical box, the outlets are then on the evaporator. Before attempting any adjustments, make same side of the case but at the opposite end.
  • Page 14: Refrigeration Data

    Refrigeration (Cont'd) Refrigeration Data Estimated Charge (lb)*** Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H. Note: Not recommended to control temp by regulating coil temp allow T-STAT to cycle and control temp. Front *Dependent on case length and refrigerant type.
  • Page 15: Electrical

    Electrical Wiring Color Code Electrical Service Receptacles (When Applicable) The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays. They are not intended nor suitable for large motors or other external appliances. BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY...
  • Page 16: User Information

    User Information Stocking Non-Glare Glass (Optional) Improper temperature and lighting will cause serious The high optical clarity of this glass is possible due to product loss. Discoloration, dehydration and spoilage special coatings on the glass surface itself. To preserve this can be controlled with proper use of the equipment and coating and the optical clarity, keep the glass clean.
  • Page 17: Case Cleaning

    User Information (Cont'd) Case Cleaning the front glass is “lift up glass” and is NOT sealed. IT Long life and satisfactory performance of any equipment WILL LEAK.) Keep all water within the base of the are dependent upon the care given to it. To insure long life, case.
  • Page 18: Stainless Steel Cleaning And Care

    User Information (Cont'd) Don’t Despair! Here are a few steps that can help prevent Front Deck Pan Placement stainless steel rust. ATTENTION! When reassembling the front self-service portion 1. Use the Proper Tools of the case, assure proper installation of bottom When cleaning your stainless steel products, take deck pan.
  • Page 19: Electrical Wiring Diagrams

    Electrical Wiring Diagrams R3M/F - HV HIGH VOLUME DIGITAL T-STATS, ROPE HTRS NO 2H23644 CALRODS DIGITAL T-STATS, ROPE HTRS NO 2H23645 CALRODS DIGITAL 208V, ROPE HTRS NO CALRODS 2H18308 DIGITAL 208V, ROPE HTRS NO CALRODS 2H18309 DIGITAL T-STATS, ROPE HTRS NO 2H17722 CALRODS DIGITAL T-STATS, ROPE HTRS NO...
  • Page 20: Wiring Diagrams

    REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING 1025305 2016/01/28 RELEASED TO PRODUCTION 120V SOLENOID 1. 6 .16A @ 120VAC TOP SECTION BACK ROW FRONT ROW NOTE FOR GFCI PROTECTION: IF MORE THAN ONE SINGLE CIRCUIT # 2 (optional) LIGHTING LIGHTING...
  • Page 21 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING 1025305 2016/01/28 RELEASED TO PRODUCTION 120V SOLENOID 2. 3 .16A @ 120VAC TOP SECTION FRONT ROW BACK ROW NOTE FOR GFCI PROTECTION: IF MORE THAN ONE SINGLE CIRCUIT # 2 (optional) FRONT CANOPY LIGHTING...
  • Page 22 REVISION HISTORY GRAVITY COIL CIRCUIT #2 CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING LOADING SOLENOID 999270 2015/08/25 RELEASED TO PRODUCTION .07A @ 208/240VAC 1005239 2015/09/29 ADDED 3RD T-STAT 208/240V 120V SOLENOID 0. 2 1 2.
  • Page 23 GRAVITY COIL REVISION HISTORY CIRCUIT #2 CIRCUIT #1 SOLENOID DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING LOADING .07A @ 208/240VAC 999270 2015/08/25 RELEASED TO PRODUCTION 1005239 2015/09/29 ADDED 3RD T-STAT 208/240V 120V SOLENOID 0. 2 1 3.
  • Page 24 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING 996474 2015/08/13 RELEASED TO PRODUCTION 1005239 2015/09/29 REMOVED ARM HEATERS 120V SOLENOID 2. 9 .16A @ 120VAC TOP SECTION FRONT ROW BACK ROW LIGHTING LIGHTING CIRCUIT # 2 (optional) NOTE FOR GFCI PROTECTION: IF MORE THAN ONE SINGLE FRONT CANOPY...
  • Page 25 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY OPTIONAL LOADING 996474 2015/08/13 RELEASED TO PRODUCTION 1005239 2015/09/29 REMOVED ARM HEATERS 120V SOLENOID 4. 2 .16A @ 120VAC TOP SECTION FRONT ROW BACK ROW LIGHTING LIGHTING NOTE FOR GFCI PROTECTION: IF MORE THAN ONE SINGLE CIRCUIT # 2 (optional) FRONT CANOPY...
  • Page 26: Appendices

    Appendices Appendix A. - Temperature Guidelines 1.3 A clogged waste outlet blocks refrigeration. The The refrigerators should be operated according to the installer is responsible for the proper installation manufacturer’s published engineering specifi cations for of the system which dispenses condensate waste entering air temperatures for specifi...
  • Page 27: Appendix D. - Recommendations To User

    Appendices (Cont'd) 1.1 The following recommendations are made 7. Are there unusual draft conditions (from for the purpose of arriving at easily taken and heating/air-conditioning ducts, open understood data which, coupled with other doors, etc.)? observations, may be used to determine whether 8.
  • Page 28 Appendices (Cont'd) 1.1 Cleaning of non frozen food equipment d) Care must be taken when cross should include a weekly cleaning of the food merchandising products to ensure that compartment as a minimum to prevent bacteria potentially hazardous vegetable products are growth from accumulating.
  • Page 29 August 31, 2018 This warning does not mean that Hussmann products will cause cancer or reproductive harm, or is in violation of any product-safety standards or requirements. As clarified by the California State government, Proposition 65 can be considered more of a ‘right to know’...
  • Page 30 Service Record Last service date: _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular Additional copies of this publication may be obtained by contacting: unit.