Connecting to an existing Thermistor Inside the Battery
If the battery pack has a built in 10k thermistor with both leads floating or one connected to battery negative then you
can use it as the temperature sensor (you'll need a temperature probe connector on the back of the UBA for this).
Contact us for more information.
Running a Battery Analysis
When you are setting up a battery analysis, click on the Options tab and select a temperature probe. If you want the
charging to be controlled by temperature then you'll need to set this in the BAR. For NiCd/NiMH charging, open the
BAR in the BAR designer and click the charging action. Select the Finished tab and check Temperature Probe. On
the Temperature tab you can set the temperature rise rate and maximum temperature. When enabled, if either of
these conditions are met then the charging cycle ends.
Figure 33: Temperature conditions that terminate battery charging for NiCd/NiMH cells.
The BAR Designer has a option where if the temperature probe reaches a specified temperature, the battery analysis
is ended.
Figure 34: Maximum battery temperature in a BAR (mainly used for lithium cell charging).