turck TW-R10-M-B146 Operating Instructions Manual
turck TW-R10-M-B146 Operating Instructions Manual

turck TW-R10-M-B146 Operating Instructions Manual

Rfid tags with a password function
Hide thumbs Also See for TW-R10-M-B146:

Advertisement

Quick Links

Your Global Automation Partner
TW-R...-M-B146
RFID Tags with a Password
Function
Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TW-R10-M-B146 and is the answer not in the manual?

Questions and answers

Summary of Contents for turck TW-R10-M-B146

  • Page 1 Your Global Automation Partner TW-R…-M-B146 RFID Tags with a Password Function Operating Instructions...
  • Page 2 Contents Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 3: Table Of Contents

    Contents About These Instructions Target groups Explanation of symbols Other documents Naming convention Feedback about these instructions Notes on the Product Product identification Scope of delivery Legal requirements Manufacturer and service For Your Safety Intended use Obvious misuse General safety notes Product Description Device overview Properties and features...
  • Page 4 Addressing password protected areas of a tag Troubleshooting Maintenance Repair 10.1 Returning devices Disposal Technical Data Appendix: EU conformity declaration Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 5: About These Instructions

    This symbol denotes actions that the user must carry out. RESULT OF ACTION ➥ This symbol denotes the relevant results of actions and procedures. Other documents Besides this document the following material can be found on the Internet at www.turck.com: ■ Data sheet ■ Device approvals ■...
  • Page 6: Feedback About These Instructions

    For overseas inquiries contact your national Turck representative. Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Mülheim an der Ruhr Germany Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 7: For Your Safety

    The product is designed according to state of the art technology. Residual hazards, however, still exist. Observe the following warnings and safety regulations in order to prevent danger to persons and property. Turck accepts no liability for damage caused by failure to observe these warnings and safety instructions.
  • Page 8: Product Description

    Information about compatible devices is provided in the relevant product data sheet. An overview of other RFID system components is provided in the RFID engineering manual. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 9: Mounting

    Mounting The tags can be fitted flush to the mounting environment. An undermount installation (1 mm in metal) will reduce the read/write distance by approx. 30 %. Aligning tags to the read/write head Align tags to the read/write head as shown in Fig. 3. ➤...
  • Page 10: Fastening Tags To The Object

    Optional: Fill any recess or cavity with adhesive. ➤ ➤ Optional: Spread the adhesive to produce a flush surface. ➤ ➤ Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 11: Operation

    Operation NOTE The achievable read/write distances may vary according to factors such as component tolerances, mounting locations, ambient conditions and the effect of materials. For this reason, the application must be tested in all cases under real conditions (particularly with read and write operations in motion). Setting –...
  • Page 12 RFID electronic modules – Firmware version Read/write head Ident-No. FW version BL20-2RFID-A 6827233 SR49 BL67-2RFID-A 6827225 SR49 BL20-2RFID-S 6827306 SR49 BL67-2RFID-S 6827305 SR49 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 13: Blxx-2Rfid-A Module - Overview Of Commands

    BLxx-2RFID-A module – Overview of commands The commands required for the password function are sent to the BLxx-2RFID-A module via a Get command. For this the following entries must be made with all commands: ■ CMDREF[x].CMD = 0x62 ■ Refer to the descriptions of the individual commands for the values for CMDREF[x].length. 7.2.1 Set Transceiver PWD command The Set Transceiver PWD command sets a password in the read/write head via a Get command.
  • Page 14 Get.request TXBUF[1] TXBUF[2] Password byte [0] TXBUF[3] Password byte [1] TXBUF[4] Password byte [2] TXBUF[5] Password byte [3] Get.response RXBUF[1] Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 15: Set Tag Pwd Command

    7.2.2 Set Tag PWD command The Set Tag PWD command sets a password in the tag via a Get command. After the password is sent, other commands (e.g. Set_Tag_Protection) can be sent to the tag. Basic status Ready? ERROR = true Error? (XIN0 = true) DONE = true?
  • Page 16 Get.request TXBUF[1] TXBUF[2] Password byte [0] TXBUF[3] Password byte [1] TXBUF[4] Password byte [2] TXBUF[5] Password byte [3] Get.response RXBUF[1] Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 17: Set Tag Protection Command

    7.2.3 Set Tag Protection command The Set Tag Protection command defines the password protection for the tag via a Get com- mand. For this it has to be specified whether a write protection or a read protection should be set and the area of the tag to which the password applies. Protection for all areas is defined with one command.
  • Page 18 Flow diagram for Set Tag Protection command Get.request TXBUF[1] TXBUF[2] Write, bit 0…7 TXBUF[3…5] TXBUF[6] Read, bit 0…7 Get.response RXBUF[1] Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 19: Get Tag Protection Status Command

    7.2.4 Get Tag Protection Status command The Get Tag Protection Status command scans whether a specific area of the tag is password protected. Basic status Ready? ERROR = true Error? (UIN0 = true) DONE = true? Execute command TXBUF[1] = 8 „GET“...
  • Page 20: Resetting The Password In The Read/Write Head

    Waiting for next command Fig. 10: Flow diagram for resetting the password in the read/write head Get.request TXBUF[1] Get.response TXBUF[1] Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 21: Blxx-2Rfid-S Module - Overview Of Commands

    BLxx-2RFID-S module – Overview of commands 7.3.1 BLxx-2RFID-S module – Process output data Byte no. XCVR NEXT TAG_ID READ WRITE TAG_INFO XCVR_INFO RESET res. Domain_Count res. Byte_Count 2 Byte_Count 1 Byte_Count 0 AddrHi AddrLo 8 bytes write data (WRITE_DATA) 2018/04...
  • Page 22: Set Transceiver Pwd Command

    The password set in the read/write head here must match the tag password. Refer to chapter „Setting password protection for tags” for the procedure in the application. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 23 Get.request StartAddress WRITE_DATA[0] Password byte [0] WRITE_DATA[1] Password byte [1] WRITE_DATA[2] Password byte [2] WRITE_DATA[3] Password byte [3] WRITE_DATA[4…7] 2018/04...
  • Page 24: Set Tag Pwd Command

    The password set in the read/write head here must match the tag password. Refer to chapter „Setting password protection for tags” for the procedure in the application. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 25 Get.request StartAddress WRITE_DATA[0] Password byte [0] WRITE_DATA[1] Password byte [1] WRITE_DATA[2] Password byte [2] WRITE_DATA[3] Password byte [3] WRITE_DATA[4…7] 2018/04...
  • Page 26: Set Tag Protection Command

    Read, bit 4 Write, bit 5 Read, bit 5 Write, bit 6 Read, bit 6 Write, bit 7 Read, bit 7 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 27 Ready for RFID- communication Ready? ERROR = true (XCVR_ON = true) Error? (DONE = true) Preallocate values: Byte Count = 7 WRITE DATA [0] = write, bit 0…7 WRITE DATA [4] = read, bit 0…7 GET command (GET = true) [false ©...
  • Page 28: Get Tag Protection Status Command

    (DONE = true) XCVR_CON = true (BUSY = false) XCVR_ON = true Fig. 14: Flow diagram for Get Tag Protection Status Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 29 Get.request StartAddress WRITE_DATA[0…7] Get.response READ_DATA[0] Write, bit 0…7 READ_DATA[1…3] READ_DATA[4] Read, bit 0…7 READ_DATA[5…7] 2018/04...
  • Page 30: Resetting The Password In The Read/Write Head

    XCVR_ON = true (BUSY = false) Fig. 15: Flow diagram for Reset read/write head Get.request StartAddress WRITE_DATA[0…7] Get.response StartAddress WRITE_DATA[0…7] Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 31: Setting Password Protection For Tags

    Setting password protection for tags The following flow diagrams describe the programming of the tags. 7.4.1 Multiple tags with the same password in an application (example) Start Define password Write desired data to data carrier Read-write-head connected? (XCVR_CON = true) Cpmmand: Set_transceiver_password (with default passwort of...
  • Page 32: Multiple Tags With Different Passwords In An Application (Example)

    3) Save data in control or database Command: Set_tag_password Command: Set_transceiver_password (with new password) Command: Set_tag_protection Fig. 18: Multiple tags with different passwords – Programming tags Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 33 Start Read UID Command: Set_transceiver_password (with the password stored in the database) Command: Read … Write … new data carrier Fig. 19: Multiple tags with different passwords – Access in the application 2018/04...
  • Page 34: Setting Password Protection Via Fdt/Dtm

    Write the required user data to the tag (in the example: 8 bytes, data 1122334455667788). ➤ ➤ Fig. 20: Writing user data to the tag Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 35 Set the password of the read/write head to 0 (default setting of the tag) ➤ ➤ Fig. 21: Setting the password of the read/write head to 0 Set the defined password in the tag. ➤ ➤ Fig. 22: Setting a new password in the tag (example: 11223344) 2018/04...
  • Page 36 Fig. 23: Setting a new password in the read/write head (example: 11223344) Set write protection or read protection ➤ ➤ Fig. 24: Setting read/write protection Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 37 Fig. 25: Setting read protection 2018/04...
  • Page 38: Addressing Password Protected Areas Of A Tag

    E1FE0200. Tag within the detection range The TP bit (Tag present) is set irrespective of password protection. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 39: Troubleshooting

    The devices are maintenance-free, clean dry if required. Repair The device must not be repaired by the user. The device must be decommissioned if it is faulty. Observe our return acceptance conditions when returning the device to Turck. 10.1 Returning devices If a device has to be returned, bear in mind that only devices with a decontamination declara- tion will be accepted.
  • Page 40: Technical Data

    Plastic, open housing, encapsulated Plastic, open housing, encapsulated Material of active face Plastic, black, PPS Plastic, black, PPS Degree of protection IP68 IP68 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
  • Page 41: Appendix: Eu Conformity Declaration

    Appendix: EU conformity declaration Hans Turck GmbH & Co. KG hereby declares that wireless system types TW-R…M-B146 com- ply with directive 2014/53/EU. The complete text of the EU declaration of conformity can be obtained from the following Internet address: www.turck.com...
  • Page 42 Over 30 subsidiaries and over 60 representations worldwide! D500054 | 2018/04 *D500054* www.turck.com...