Stoelting 219 Owner's Manual page 23

Mix pump
Table of Contents

Advertisement

A. DAILY CHECK
1.
Check for any unusual noise or condition and
repair immediately.
B. WEEKLY CHECK
CAUTION
THE MIX PUMP SWITCH MUST BE IN THE OFF
POSITION WHEN SERVICING OR CLEANING
PUMP.
1.
Clean and lubricate with liquid sanitary
lubricant or equivalent, the two guide rods on
the pump motor. Apply lubricant to rods with
fingers to eliminate spray accumulation on
other components. Remove the two knobs and
safety guard for access.
C. FOUR MONTH CHECK
1.
Every four months, or as required, replace quad
ring in mix pump if worn, or low over-run will
result.