5.4 SNMP interface

Object
MIB-2
(iso.org.dod.internet.mgmt.mib-2.sysem.x / .1.3.6.1.2.1.1.x)
sysDescr
sysUpTime
sysName
sysLocation
ATHENA-MIB A060-Mini
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.x / .1.3.6.1.4.1.36043.1.x)
A060-MiniLinkQuality
A060-MiniReceivePower
A060-MiniTemperature
A060-MiniLocDetector
A060-MiniifEthernetIn
A060-MiniifEthernetOut
A060-MiniifEthernetError
A060-MiniifAirIn
A060-MiniifAirOut
A060-MiniifAirInError
A060-MiniFirmwareversion
ATHENA-MIB A060-Minitraps
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.miniTraps.x / .1.3.6.1.4.1.36043.1.22.x)
A060-MiniLinkQualityImprovedTrap
A060-MinilinkQualityReducedTrap
A060-MiniTemperatureHighTrap
A060-MiniTemperatureLowTrap
Page 13
OID
OID type
.1.
DisplayString
.3.
TimeTicks
.5.
DisplayString
.6.
DisplayString
.1.
Integer
.10.
Integer
.11.
Integer
.12.
Integer
.15.
Integer
.16.
Integer
.17.
Integer
.18.
Integer
.19.
Integer
.20.
Integer
.21.
String
.1.
Integer
.2.
Integer
.3.
Integer
.4.
Integer
Description
Includes serial no.
Uptime of the network management
set in the web GUI
set in the web GUI
1: Green
2: Yellow
3: Red
Receive signal level [dBm]
Temperature [˚C]
Lock detection signal level
Total frames received on the Ethernet interface over a
period of 10 seconds.
Total frames sent on the Ethernet interface over a
period of 10 seconds.
Total frames dropped due to errors received on the
Ethernet interface over a period of 10 seconds
Total frames received on the Air interface over a period
of 10 seconds.
Total frames sent on the Air interface over a period of
10 seconds.
Total frames dropped due to errors received on the Air
interface over a period of 10 seconds.
Installed firmware version
1: from red to green
2: from red to orange
3: from orange to green
1: from red to green
2: from red to orange
3: from orange to green
A trap indicating that the temperature within the unit is
at or
above
70 degree Celcius
A trap indicating that the temperature within the unit is
at or below -40 degree Celcius