Digital Control Installation Instructions

1. The digital control can be located inside or outside the shower area. Position the touch pad 4
to 6 feet from the floor inside or outside the steam room. Drill one 1-1/16" hole in the wall.
2. Bring the control wire from the generator through the 1-1/16" hole. Carefully connect the wire
to the pigtail of the control using the supplied coupler. DO NOT pinch, nail, wedge etc. the
control cable, any damage to the control cable will result in the control not working
properly. If the control is not installed immediately, protect the end connectors with
some type of shielding material.
3. Carefully connect the other end of the lead wire to the generator BEFORE turning
power on to the generator.
4. Turn on both water and power to the generator.
5. Test the touch pad to ensure it is properly connected. If any technical problems arise, call toll
free 800-585-7832.
6. THESE STEPS MUST BE TAKEN OR YOUR WARRANTY WILL BE VOID. Coat the entire
control back with supplied waterproof silicone. Completely seal the control to the wall so
moisture does not get behind it. Place the control on the wall pressing firmly. You may need
to tape the control into place until the silicone dries. Be careful not to harm the wall/control
with the tape. Refer to figure 4. Let dry for 24 hours before using steam bath.
Failure to follow installation instructions specifically may cause the warranty to be void!
Completely Silicone the
back area of Control
DOC NO. 81009
6 OF 9
Cable from
Generator
1-1/16"
Hole
Figure 4
Rev A 10/03