Testing The Smrt Au10 - Marine Rescue Technologies sMRT AU10 User Manual

Dual operating personal locator beacon
Table of Contents

Advertisement

14
sMRT AU10 User Manual v1.8

5.1 Testing the sMRT AU10

A full system test is performed prior to the sMRT AU10 being installed into
an MRT approved PFD. The device is [OFF] when shipped in a PFD and
needs to be configured in the [READY] state prior to use. A full system test
should also be performed.
WARNING: After deployment into active service, a regular full
system test of the sMRT AU10 should be performed every 3 months.
Do not test the device more than once per month as this could affect
battery performance in an emergency. MRT also mandates each
device is returned to MRT, or an authorised service agent, for annual
servicing and recertification.
Low Power Function Test Mode: Battery Testing
Ensure the ARMING SWITCH is in the [OFF] position.
1. Press and hold the round rubber ACTIVATION BUTTON to
activate function test mode.
2. Observe the ANTENNA LED:
a. GREEN LED = Batteries OK
b. No LED = Battery recertification required
c. RED LED = Battery recertification required
3. To cancel function test mode and the battery function test:
a. Stop pressing the ACTIVATION BUTTON, or
b.
Lift the
RUBBER O-RING
SWITCH, push the ARMING SWITCH down, then
immediately up to cancel the function test.
up and over the
ARMING
MRT Ltd. © 2014