Download Print this page

Supra TRACcess TRAC-Vault BT Smart Installation Instructions Manual page 2

Surface mount anti-theft key lock storage unit

Advertisement

Available languages

Available languages

2
— Make sure TRAC-Vault BT devices is mounted flush
with masonry surface and the masonry screws are only
installed directly into brick.
— Minimize all gaps between back of TRAC-Vault BT
devices and masonry surface.
Rendered Wall Installation:
1. While holding the vault in the desired position on the
wall, locate the four mounting holes away from mortar
lines and the edge of the wall.
2. Using a marker, trace the location of all four (4)
mounting holes (see Figure 1).
3. Using a drill with an 8 mm masonry drill bit, drill each
hole to a depth of 105 mm.
4. Verify each hole aligns with the four (4) holes in the
back of the vault.
5. Clean out the debris from all four (4) holes.
6. Insert one of the HECO mounting screws onto the
chain mounting bracket (see Figure 2).
7. Place the TRAC-Vault up to the wall (drain hole down)
and insert each mounting screw all the way through
the mounting holes in the vault, with the chain
mounting bracket in the lower left hole.
8. Tighten all four (4) screw heads in the order shown in
Figure 1 until they are flush with the back of the vault,
and behind the vault lip.
9. Using the appropriate driver, tighten all four (4) screws
into the wall a little at a time until all four (4) screws
are secure and the vault is tight against the wall.
Figure 5. Side view, TRAC-Vault BT installed through the wall
TRAC-Lid BT
Lid chain
attachment
Lock washer
Nut
TRAC-Vault
Vault
chain bracket
Drain hole
Figure 3. Optional Tamper Switch
AMP FDVH-187C
quick connector
14/16 AWG wire
Figure 4. Installed TRAC-Lid
TRAC-Vault
Tamper switch
adjustment screw
1 Normally open
2 Normally closed
3 Common
To alarm
Indicator
light
TRAC-Lid BT
Thumb lever
Wall
Back plate
All-thread rod
Nut
Lock nut
Fender washer

Advertisement