RATINGS - NATURAL AND L.P. PROPANE GAS

GG SERIES
Hot Water Model
RATINGS FOR WATER
A.G.A.
MODEL
INPUT
NUMBER ±
(Btuh)
GG-75H
75,000
GG-100H
100,000
GG-125H
125,000
GG-150H
150,000
GG-175H
175,000
GG-200H
200,000
GG-225H
225,000
GG-250H
250,000
GX and GXH
Hot Water Models (tankless heaters)
RATINGS STEAM OR WATER
A.G.A.
MODEL
INPUT
NUMBER †
(Btuh)
GXHA-100
100,000
GXH-105
105,000
GXHA-120
120,000
GXH-125
126,000
GXH-150
147,000
GXHA-160
160,000
GXH-170
168,000
GXH-190
189,000
GXHA-200
200,000
GXH-210
210,000
GX-225
225,000
GXH-230
231,000
GX-250
250,000
GXH-250
252,000
GXH-275
273,000
GXH-300
300,000
GXH-300H§
300,000
± GG models: Add suffix "S" for standard water boiler, "P" for
packaged water boiler. Add suffix "E" for intermittent pilot igni-
tion system (available only with 24 volt gas valve). Type of
gas: After model number, specify gas by name "Natural" or
"Propane"
* Net ratings are based on a piping and pick-up allowance of
1.33 (steam) and 1.15 (hot water). Slant/Fin should be con-
sulted before selecting a boiler for installation having
unusual piping and pick-up requirements. Ratings must
be reduced by 4% at 2,000 feet elevation and an addition
al 4% for every additional 1,000 feet elevation over 2,000
feet.
equipment
ALL MODELS include pre-assembled heat exchanger; base; flue collector; gas
burners; gas orifices and manifold assembly; combination gas valve including
manual shut-off, pressure regulator, pilot adj., automatic pilot-thermocouple safety;
pressure relief valve (ASME); draft hood (integral draft diverter in GXHA models);
blocked vent safety switch; rollout safety switch; pre-assembled insulated semi-
extended jacket (extended as shown); automatic vent damper (except GG-300
through GG-399 and GXH-300).
BASIC WATER BOILER (SUFFIX S) includes all equipment listed for ALL MODELS,
plus built-in air eliminator; hi limit control; pressure and temperature gauge.
PACKAGED WATER BOILER (SUFFIX P) includes all equipment listed for ALL
MODELS and for model S, plus 2-way combination control (hi limit and circulator
relay), instead of hi limit control; circulator; drain cock.
PACKAGED WATER BOILER WITH TANKLESS HEATER (SUFFIX PT) includes all
Before purchasing this appliance read important energy costs
and efficiency information available from your contractor.
NET I=B=R
D.O.E.
RATING
WATER
CAPACITY
WATER
(Sq.Ft.)
(Btuh)
(Btuh)*
64,000
56,000
371.3
83,000
72,000
481.3
103,000
90,000
597.3
125,000
109,000
742.6
145,000
126,000
840.6
167,000
145,000
968.0
186,000
162,000
1078.0
209,000
182,000
1211.3
GX, GXH and GXHA
D.O.E.
D.O.E.
CAPACITY
CAPACITY
WATER
WATER
STEAM
(Sq.Ft.)
(Btuh)
(Btuh)
81,000
86,000
86,000
495
97,000
104,000
104,000
600
120,000
120,000
695
130,000
137,000
137,000
795
155,000
155,000
895
163,000
172,000
172,000
995
184,000
179,000
1065
189,000
189,000
1095
204,000
198,000
1180
206,000
206,000
1195
223,000
223,000
1290
240,000 **
240,000 **
1395
243,000 **
243,000 **
1405
† GXH and GX models: Add suffix "PT" for standard water
boiler with tankless heater, "PZ" for steam boiler, "PZT" for
packaged steam boiler with tankless heater. Add suffix "E"
for intermittent pilot ignition system (available only with 24
volt gas valve). Type of gas: After model number, specify
gas by name "Natural" or "Propane".
** CSA output rating (Btuh).
§ Ratings for GXH-300H are for natural gas only.
‡ Tankless heater ratings based on intermittent draw.
NOTE: All boilers under 300,000 Btu input are tested and
rated for capacity under the U.S. Dept. of Energy (D.O.E.)
Test Procedure for boilers.
RATINGS FOR WATER
A.G.A.
MODEL
INPUT
NUMBER †
(Btuh)
GG-275H
275,000
GG-300
300,000
GG-325
325,000
GG-350
350,000
GG-350H
350,000
GG-375
375,000
GG-375H
375,000
GG-399H
399,000
Low Pressure Steam Models (optional tankless heater)
NET I=B=R*
TANKLESS
CAPACITY
WATER
STEAM
STEAM
(Btuh)
(Btuh)
(Sq.Ft.)
61,000
254
75,000
65,000
271
73,000
304
90,000
78,000
325
104,000
90,000
375
98,000
408
119,000
103,000
429
135,000
116,000
483
122,000
508
150,000
129,000
538
160,000
134,300
560
164,000
142,000
591
177,400
148,500
620
179,000
155,000
646
194,000
167,000
696
209,000
180,000
750
211,000
182,000
758
equipment listed for ALL MODELS, plus built-in air eliminator; pressure and
temperature gauge; circulator; drain cock; 3-way combination control (hi-limit,
circulator relay and lo-limit with differential); tankless heater.
PACKAGED STEAM BOILER (SUFFIX PZ) includes all equipment listed for ALL
MODELS, plus steam pressure limit control with siphon; pressure gauge; low water
cutoff and water level sight glass (unmounted); drain cock, transformer and junction
box.
PACKAGED STEAM BOILER WITH TANKLESS HEATER (SUFFIX PZT) includes
all equipment listed for ALL MODELS and for model PZ, plus tankless heater instead
of cover plate; low limit control.
OPTIONAL EQUIPMENT Room thermostat. Air package consisting of diaphragm
expansion tank, fill and pressure reducing valve, and automatic air vent. Combustible
floor kit. Intermittent pilot ignition system.
NET I=B=R
D.O.E.
RATING
CAPACITY
WATER
(Btuh)
(Btuh)*
228,000
198,000
240,000 **
209,000
260,000 **
226,000
280,000 **
243,000
291,000 **
253,000
300,000 **
261,000
304,000 **
264,000
327,000 **
284,000
GALAXY DOE SEASONAL
EFFICIENCY (AFUE)*
HEATER
MODEL
(G.P.M.)‡
GG-75 HED
2
1 /
2
GG-100 HED
1 /
2
2
GG-125 HED
3
GG-150 HED
3
GG-175 HED
1 /
3
4
GG-200 HED
3
1 /
2
GG-225 HED
3
1 /
2
GG-250 HED
3
3 /
4
GG-275 HED
4
4
GXH-105 ED
4
GXH-125 ED
4
1 /
GXH-150 ED
4
1 /
4
GXH-170 ED
2
4
1 /
GXH-190 ED
2
5
GXH-210 ED
1 /
5
GX-225 ED
2
5
1 /
GXH-230 ED
2
GX-250 ED
GXH-250 ED
GXH-275 ED
GXHA-100 ED
GXHA-120 ED
GXHA-160 ED
GXHA-200 ED
* Includes intermittent pilot and
vent damper. Annual Fuel
Utilization Efficiency based on
constant circulation for hot
water models.
THE HYDRONICS
INSTITUTE
WATER
(Sq.Ft.)
1322.0
1390.0
1510.0
1620.0
1684.0
1740.0
1760.0
1893.3
EFFICIENCY
84.78%
82.78%
82.39%
82.98%
82.45%
83.19%
82.51%
83.40%
82.57%
81.00
81.00
81.14
81.14
81.14
81.17
81.30
81.21
80.70
81.24
81.28
81.00
81.20
81.20
81.30