7. TROUBLE SHOOTING
THE PROBLEM
The forks do not reach maximum
height.
The forks do not raise.
The forks will not descend
Leaks.
The forks descend and cannot be
maintained in the raised position.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling
centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires
disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
THE CAUSE
Hydraulic oil level too low.
Too cold.
No hydraulic oil
The oil is contaminated.
Air in the hydraulic system.
Truck stored in raised position allowing
exposed piston rod to corrode and jam.
Piston rod or pump body deformed as a result
of overloading or unbalanced load.
Seals worn, damaged or cracked.
Release valve not fully closed owing to
impurities in oil.
Air in the hydraulic system.
Seals worn, damaged or cracked.
Parts of hydraulic system cracked or worn.
Environmental Protection
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
THE SOLUTION
Top up the oil.
Operate at rated temperature.
Fill with hydraulic oil
Change the oil.
Purge the air as described in Section 6.
Lubricate rod regularly and store truck
in lowered position.
Replace piston rod or pump body.
Replace seals.
Change the oil.
Purge the air as described in Section 6.
Replace seals.
Inspect and replace.