Anywire ASLINKSENSOR Product Manual

Anywireaslink system
Hide thumbs Also See for ASLINKSENSOR:

Advertisement

Quick Links

AnyWireASLINK System Products Guide
ASLINKSENSOR
[Photoelectric Diffuse Reflection Type (IP67)]
BS-H0317-1K
[Notes on Safety]
Precautions that must be observed in order to use this system safely are
indicated as shown below. You must observe these precautions.
A WARNING indicates a potentially hazardous situation which, if not
WARNING
handled correctly, could result in death or serious injury.
A CAUTION indicates a potentially hazardous situation which, if not
CAUTION
handled correctly, may result in personal injury or property damage.
○ System Safety
WARNING
This system is intended for general industrial applications. It does not
have functions for supporting applications requiring higher levels of
safety such as safety-related devices or accident prevention systems.
The product must not be used for these purposes.
○ Always turn off the power before attempting to mount or replace.
○ Prolonged continuous ow of a rated load current or higher or a transit
current due to load short-circuit, etc., in the hybrid unit including the
output unit and the output circuit may result in smoking or ring. An
external safety device such as a fuse must be installed.
○ System power supply
CAUTION
Use a stable, 24V DC power supply. Use of an unstable power supply
may cause problems with the system.
○ Separately route high-voltage and power cables
Although the AnyWireASLINK has a high noise margin, lay the transmis-
sion lines and I/O cables so as to keep them away from high-voltage
and power cables.
○ Connectors and terminals
・ Pay careful attention to the length and installation of cable wiring to
ensure that connectors and cables are neither stressed nor discon-
nected even if they are stressed.
・ Make sure to prevent any metal objects from getting inside the
connectors or the terminal blocks.
・ Short-circuits caused by metal objects or mis-wiring are likely to
damage the device.
○ Do not impose any external loads on the units. Doing so may cause a
failure.
○ Do not disconnect or reconnect between the transmission line and slave
units. A malfunction may occur.
○ Use the AnyWireASLINK within the range of the speci cations and
conditions shown below.
[Warranty]
■ Warranty period
The warranty on the delivered Product shall continue to be effective for one (1)
year after the delivery thereof to a location as designated by the original owner.
■ Scope of warranty
Should a defect occur in any part of the Product during the foregoing warranty
period when it is used normally in acordance with the speci cations described in
this User's Manual, the Company shall replace or repair the defect free of
charge, except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner;
[2] Fault caused by other than the delivered Product;
[3] The unauthorized modi cation or repair of the Product by any person other
than the Company's personnel;
[4] Any unusual force of nature, disaster or other cause beyond the Company's
control.
The term "warranty," as used herein, refers to the warranty applicable to the
delivered product alone. The Company shall not be liable for consequential or
incidental damages resulting from any malfunction.
■ Repair at cost
After the expiration of the warranty period, the owner shall be responsible for all
costs and expenses incurred for the troubleshooting and repair of the Product.
Even during the warranty term, the Company shall repair any defects arising
from causes other than within the scope of the warranty as speci ed above, at
the owner's cost.
[Type]
AnyWireASLINK photoelectric sensor:
Diffuse re ection type, bit operation
BS-H0317-1K
1 optical axis
-BSH03171K 1/8-
[Function]
Model
ASLINKSENSOR 2-wire (non-insulation)
Detection method
Diffuse re ection type
Sensitivity adjustment value (threshold)
Hysteresis
Alarm judgment value
Alarm judgment time
Light ON/dark ON
Operation mode
Function
Light receiving display switching
Delay timer
One shot
Sensing level drop
Slave unit voltage drop
Waterproof (IP67)
[Contents in package]
BS-H0317-1K
*Please purchase the attachment tting separately.
*An "address writer ARW-04 (Ver.04-1.01 or higher)" is required for setting to
the unit. Prepare it together.
ARW-04
Front
[Name of each part]
■Diffuse re ection type
Setting port
LINK indicator
DP (Red)
DN (Black)
Unit ... 1 unit
The version is
displayed when
POWER is on.
A "Ver.*.**" is
READER/WRITER
described on
ARW-04
Ver.04-1.01
LotNo.***
MADE IN JAPAN
this label.
Back
Input indicator
ALM indicator
Light emitting surface
Attachment tap 2-M3
Transmission cable

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASLINKSENSOR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anywire ASLINKSENSOR

  • Page 1 [Function] AnyWireASLINK System Products Guide Model ASLINKSENSOR 2-wire (non-insulation) ASLINKSENSOR Detection method Diffuse re ection type [Photoelectric Diffuse Reflection Type (IP67)] Sensitivity adjustment value (threshold) BS-H0317-1K Hysteresis Alarm judgment value Alarm judgment time [Notes on Safety] Light ON/dark ON Precautions that must be observed in order to use this system safely are...
  • Page 2: Connection Example

    [Connection Example] ■Example of mixture of 2-wire (non-insulation), 4-wire (insulation) terminals You can select use of either a two-wire or four-wire terminal for the AnyWireASLINK according to the load current. Red: DP Red: DP This Products Guide describes a two-wire (non-isolated) terminal. If the load current is small, using a two-wire (non-isolated) terminal allows for achieving AnyWireASLINK Two points...
  • Page 3 MAX 5A/24V DC the total length of 50m Filter of COSEL Co., Ltd. EAC-06-472 MAX 6A/24V DC 4-wire terminal 2-wire terminal ■AnyWire Type: ANF-01 Connection example ①Power supply to the entire system 2-wire AnyWireASLINK 24V DC stabilized General-purpose power terminal...
  • Page 4 ■COSEL Co., Ltd. Type: EAC-06-472 Connection example ② Local power supply/branching ①Power supply to the entire system * When using this lter, please be careful of the positions of LOAD and LINE. * When using this lter, please be careful of the positions of LOAD and LINE. AnyWireASLINK master LOAD...
  • Page 5: How To Connect

    [How to connect] [Example of installation] Purchase the bracket separately. Connect the transmission line included with the base unit body to the transmission line M3 tightening torque: 0.5N・m or less from the master unit. Connect correctly for the polarity of +/-. CAUTION When securing the unit, allow a margin so that Light emitting and...
  • Page 6: Parameter Setting

    [Various settings] Teaching ■Item Store the status when a work is present and when a work is absent in the ASLINKSENSOR. Address number setting Teaching Parameter setting Carry out setting with the work actually used. ■Common procedure for address writer operation [SET ON setting] Be sure to connect to the AnyWireASLINK master unit to use.
  • Page 7 ■Alarm value Hi setting ■Setting of One Shot Set an upper limit for the alarm judgment value. Set One Shot time. * Set the alarm values so that Hi is greater than Lo. - Address writer (ARW-04): Parameter 03 - Address writer (ARW-04): Parameter 12 AD value 0-100%...
  • Page 8: Speci Cations

    -Is the angle of the light emitting and receiving surface correct? cannot be performed. → When it is wrong, adjust it to the correct angle. - Are the wirings correct? → Re-check the connection of the ASLINKSENSOR Number of occupied points Input 1 point transmission line.
  • Page 9 [Address] Anywire Corporation Headquarters :1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN Contact :Contact by mail info_e@anywire.jp :Contact by website http://www.anywire.jp Printed in Japan 2016, 2017 UMA-13310C-EN -BSH03171K 9/9-...

This manual is also suitable for:

Bs-h0317-1k

Table of Contents