VERIS INDUSTRIES, INC. V100DC Installation Manual

10a spdt enclosed relay 10-30 vdc coil

Advertisement

Quick Links

TM
V100DC
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.
• This equipment must only be installed and serviced by qualified electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn off all power supplying equipment before working on or inside the equipment.
• Use a properly rated voltage sensing device to confirm power is off.
DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION
Failure to follow these instructions will result in death or serious injury.
NOTICE
• This product is not intended for life or safety applications.
• Do not install this product in hazardous or classified locations.
• The installer is responsible for conformance to all applicable codes.
• Mount this product inside a suitable fire and electrical enclosure.
DIMENSIONS
2.9"
(74 mm)
2.8"
(71 mm)
(43 mm)
1/2" NPT Nipple
Z203521-0B
PAGE 1
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
RELAYS
1.6"
(41 mm)
1.8"
1.7"
(46 mm)
©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
INSTALLATION GUIDE
V100DC
10A SPDT Enclosed Relay
10-30 VDC Coil
Installer's Specifications
Operating Temperature
Operating Humidity
Expected Relay Life
Relay Status
Wire Specifications:
Lead Length
Gauge
Insulation Class
Agency Approvals
INSTALLATION
Disconnect and lock out all power sources before beginning the
installation.
1. Using the threaded nipple, connect the relay to the desired enclosure through a
knock out hole.
2. Secure with the conduit nut provided.
3. Connect Coil:
• Choose the coil common lead (white with yellow stripe) and connect it to
the (-) source termination point.
• Choose the low voltage (10-30 VAC/DC, white with blue stripe) lead, and
connect it to the (+) source termination point.*
4. Connect Relay Contacts:
• Choose the relay common wire (yellow) and connect to switched load.
• Choose the relay N.O. (orange) and/or* N.C. (blue) lead and connect to
switched load.
5. Secure the enclosure and reconnect power.
* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e.
wire nut.
-34°C to 60°C (-29° to 140°F)
10-90% non condensing
Electrical (at rated current): 100,000 cycles
Mechanical (unpowered): 10,000,000 cycles
LED ON=energized
14" (356mm) min.
UL1015; Coil: 18 AWG; Contacts: 16 AWG
600 VAC RMS
UL508 enclosed device listing
03121

Advertisement

loading

Summary of Contents for VERIS INDUSTRIES, INC. V100DC

  • Page 1 INSTALLATION GUIDE RELAYS V100DC V100DC 10A SPDT Enclosed Relay 10-30 VDC Coil Installer’s Specifications Operating Temperature -34°C to 60°C (-29° to 140°F) Operating Humidity 10-90% non condensing Expected Relay Life Electrical (at rated current): 100,000 cycles Mechanical (unpowered): 10,000,000 cycles...