  • Page 1 For more information, please visit www.devancocanada.com or call toll free at 855-931-3334...
  • Page 3: Verification Of Operator And Hardware

    VERIFICATION OF OPERATOR AND HARDWARE Upon delivery of your MICANAN SYSTEMS medium-duty jackshaft door operator, please inspect the unit carefully for damage. Verify that operator horsepower, voltage, phase and amperage correspond to available power supply and door application. Check that along with your operator you have received the following standard hardware.
  • Page 4: Important Note

    PRO-LJ and PRO-LH medium duty jackshaft operators are designed for commercial high lift, vertical lift, rolling doors and rolling grilles provided that doors are driven by a drive shaft with low duty cycles. Model PRO-LH is essentially the same as model PRO-LJ with the exception that the PRO-LH operator incorporates a chain hoist for manual operation of the door.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF INJURY OR DEATH: READ AND FOLLOW ALL INSTRUCTIONS Never allow children to operate or play with door controls. Keep the remote control (where provided) away from children. Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened.
  • Page 6: Installation Instructions

    Remove all door locks prior to installation. - The PRO-LJ and PRO-LH operators have dual output shafts and may be mounted on left (standard) or right hand side of door. If handing of operator must be reversed, loosen set screws, remove drive sprocket and keyway and install on opposite side of drive shaft.
  • Page 7 Carefully re-align sprockets, if necessary and secure keyway and set screws. (For the PRO-LH model) Install hand chain by wrapping it through chain guard holes and pocket wheel. Allow chain to hang down towards floor. Cut chain and connect so that chain is 2’ to 3’ from the floor.
  • Page 8 Install chain keeper to wall near hand chain at approximately 4’ from floor. Run disconnect chain through keyhole of chain keeper and cut excess chain links if required. Attach keyring to end of disconnect chain. If an optional floor level disconnect lever was ordered in lieu of the chain keeper, mount to wall with suitable hardware.
  • Page 9: Electrical Connections

    Connections and logic board instructions. Refer to electrical drawings inside your operator control box or generic drawings MSLLHR-WW or MSLLHR220-WW, in the electrical drawings section at the end of this manual. IMPORTANT MICANAN HIGHLY RECOMMENDS THAT EACH INDIVIDUAL COMMERCIAL DOOR OPERATOR HAVE IT’S OWN DEDICATED POWER SUPPLY MICANAN HIGHLY RECOMMENDS THAT EACH INDIVIDUAL COMMERCIAL...
  • Page 10: Limit Switch Adjustment

    SECTION A: PRO-LJ, PRO-LH Standard relay logic controls (not UL325 (2010) compliant, not available in US) CONNECTION OF POWER SUPPLY AND CONTROL STATION POWER WIRING: Use 1-1/8” (2.85 cm) diameter holes for all power wiring. Single phase: Connect single phase power supply to terminals L/L1 (line) and N/L2 on three-pole power terminal strip.
  • Page 11 CONNECTION OF A REVERSING EDGE DEVICE AND CONTROL ACCESSORIES Reversing Edge device (must be normally open contact): Note: If the door is controlled by any device or wired in such a manner that the door is not controlled by constant pressure on close then an appropriate reversing edge must be installed.
  • Page 12 NOTE: THIS OPERATOR COMES WITH AN INTERFACE MODULE INTEGRATED INTO THE CONTROL CIRCUIT. THE PURPOSE OF THE INTERFACE MODULE IS TO ALLOW FOR FAILSAFE MONITORING OF A MICANAN COMPATIBLE SAFETY DEVICE AS PER UL 325 (2010) REQUIREMENTS. Important: Follow these steps carefully and in the order shown 1) Connect Power supply: Single phase: Connect single phase power supply to terminals L/L1 and N/L2 on the 3-pole power terminals strip.
  • Page 13 3-phase operators (1/2 HP 380V 50Hz): If door moves in wrong direction, turn off incoming power and reverse any two of the three incoming power supply leads to correct rotation. Press the open button and then activate the open limit to ensure door stops.
  • Page 14 Note: Only one monitored failsafe safety device can be connected across terminals P1 and P2. Note: See section E for complete installation instructions for the Micanan N-1 or N-4 photocells or the FRABA photocells. Secondary non-monitored safety device(s): A standard 2-wire safety edge, non-monitored reflective or thru-beam photo eye or any other non-monitored reversing devices with a N.O dry contact can be connected to terminals S1 and S2.
  • Page 19 SECTION D: For all operator control types LIMIT SWITCH ADJUSTMENT Adjustment of door travel is done by moving the limit cams on the threaded shaft. The position of the 4 limit switches are factory adjusted and should not be altered. The limit switches are: - “Open”...
  • Page 20 IMPORTANT: For momentary activation on close, the MICANAN photobeams (or a Micanan 2-wire monitored edge), must be installed as part of the operator system. If a Micanan 2-wire monitored edge or the MICANAN infrared photobeam system is not installed (or not operating correctly), the operator will only operate in fault mode (constant pressure to close).
  • Page 22 When the photo system is properly installed and aligned, the infrared beam will detect any obstruction in the path of the beam. Upon detecting an obstruction, closing door will stop and reverse to full open. The MICANAN operator control circuit continuously monitors the correct operation of the photo system.
  • Page 23 FRABA N-4/4X THRU-BEAM PHOTOCELL (MK00697) Note: The MK00697 photocell system has a maximum range of 45 ft. Sun visor protector optional. Select a location on the wall no more than 6 inches from the floor to install wall mounting brackets on the left and right side of the door.
  • Page 24: Clutch Adjustment

    CLUTCH ADJUSTMENT Remove cotter pin tapped to pulley. Rotate clutch nut counterclockwise (loosen) until there is insufficient tension to permit clutch to drive door. Gradually tighten clutch nut until the tension on belleville washers is sufficient to permit clutch to drive door smoothly but will allow clutch to slip if door is obstructed.
  • Page 25: Emergency Manual Operation

    For PRO-LH operators: Operate door by pulling on hand chain. To return to electrical operation release disconnect chain and allow to return to original position. Lock hand chain in place (to Chain Keeper or Floor Level...
  • Page 26: Operator Maintenance

    OPERATOR MAINTENANCE WARNING TO REDUCE THE RISK OF INJURY OR DEATH: DO NOT ATTEMPT TO SERVICE THE OPERATOR UNLESS POWER SUPPLY HAS BEEN DISCONNECTED Inspect manual function of the door every 3-months. Make sure that door runs smoothly. If door does not manually open or close freely, have a qualified service person make repairs.
  • Page 39: Repair Parts

    HOW TO ORDER REPAIR PARTS DEVANCO CANADA 19192 HAY ROAD, UNIT Q SUMMERSTOWN, ON K0C 2E0 TOLL FREE: 855-931-3334 www.devancocanada.com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: 3 PART NUMBER 3 DESCRIPTION 3 MODEL NUMBER...