Tait TD9300 Installation Manual

Data terminal

Advertisement

Quick Links

DRAFT 3
TD9300 Data Terminal
Installation Manual
MNE-00003-01 · Issue 1 · March 2015

Advertisement

Table of Contents
loading

Summary of Contents for Tait TD9300

  • Page 1 DRAFT 3 TD9300 Data Terminal Installation Manual MNE-00003-01 · Issue 1 · March 2015...
  • Page 2 Code, or in any other way convert the Object Code into without prior written permission from Tait Limited. a human-readable form. Protected by U.S. Patents The words TAIT, TAITNET and the TAIT logo are 5,870,405, 5,826,222, 5,754,974, 5,701,390, registered trademarks of Tait Limited.
  • Page 3: Table Of Contents

    4.4 System Connections ..........24 TD9300 Installation Manual © Tait Limited March 2015...
  • Page 4 Tait Software License Agreement ........
  • Page 5: Preface

    It includes information on installing the TD9300 in a TN9300 DMR trunked network. Document Conventions The TD9300 data terminal has a web interface with an accordion menu on Rewrite this when UI is the left side of the screen. “Configuration > Users” means click finalised.
  • Page 6: Associated Documentation

    The characters xx represent the issue number of the documentation. Technical notes are published from time to time to describe applications for Tait products, to provide technical details not included in manuals, and to offer solutions for any problems that arise. Look for new or updated technical notes on the Tait Technical Resources website.
  • Page 7: Safety And Regulatory Information

    Ce nombre est calculé pour une installation typique, ayant un émetteur de 25W. D’autres configurations, incluant les installations ayant des sites de plusieurs émetteurs, doivent être installées de façon à se conformer aux normes pertinentes des expositions RF. TD9300 Installation Manual Safety and Regulatory Information © Tait Limited March 2015...
  • Page 8: Led Safety (En60825-1)

    IEEE C95.1 2005: Norme pour les niveaux de sécurité compatibles avec l'exposition des personnes aux champs électromagnétiques de radiofréquence 3kHz à 300GHz 1.1.3 LED Safety (EN60825-1) This equipment contains Class 1 LED Products. TD9300 Installation Manual Safety and Regulatory Information © Tait Limited March 2015...
  • Page 9: Equipment Safety

    Antenna Load Transmitting into a low VSWR will maximize the power delivered to the antenna. Notice Do not remove the load from the TD9300 while it is transmit- ting. Load transients (switching or removing the load) can damage the transmitter.
  • Page 10: Esd Precautions

    ESD S20.20-1999 or BS EN 100015-4 1994. Figure 1.1 Typical antistatic bench set-up common point ground (building ground or mains ground) dissipative rubber bench mat conductive wrist strap TD9300 Installation Manual Safety and Regulatory Information © Tait Limited March 2015...
  • Page 11: Environmental Conditions

    The humidity should not exceed 95% relative humidity through the specified operating temperature range. 1.3.3 Dust and Dirt The TD9300 has the following ingress protection ratings: IP40 ■ IP51 (dust category 2) with the front panel connectors facing down. ■...
  • Page 12: Regulatory Information

    1.4.5 Unauthorized Modifications Any modifications you make to this equipment which are not authorized by Tait may invalidate your compliance authority’s approval to operate the equipment. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
  • Page 13: Introduction

    DRAFT 3 Introduction The TD9300 Data Terminal is an element of the Tait solution for grid automation on electricity distribution networks. It uses its RF capability to connect over the Tait DMR Tier III trunked network to exchange DMR control channel and packet data messages with the Tait SCADA Gateway.
  • Page 14 DRAFT 3 TD9300 Installation Manual Introduction © Tait Limited March 2015...
  • Page 15: Installation

    Figure 3.3 on page 18). These holes allow the TD9300 to be mounted flat against the DIN rail. Up to two units may be mounted in this way across a 19 inch rack or cabinet. Notice Make sure that the mounting rail is strong enough to bear the weight of the TD9300 units without bending.
  • Page 16 DRAFT 3 Figure 3.1 DIN rail mounting Recommended mounting method 35mm DIN rail M3 Taptite screw (x4) torque to 15lbf·in (1.7N·m) Mounting Removal TD9300 Installation Manual Installation © Tait Limited March 2015...
  • Page 17 DRAFT 3 Figure 3.2 Flat mounting M4 Taptite screw (x4) torque to 22lbf·in (2.5 N·m) TD9300 Installation Manual Installation © Tait Limited March 2015...
  • Page 18 Figure 3.3 Location of mounting holes in the chassis 2.38 in (60.5 mm) 2.38 in (60.5 mm) 1.42 in (36 mm) M4 Taptite (x4) M3 Taptite (x10) 6.5 in (165 mm) TD9300 Installation Manual Installation © Tait Limited March 2015...
  • Page 19: Connection

    DRAFT 3 Connection This chapter provides detailed information on connecting the various inputs and outputs on the front panel. TD9300 Installation Manual Connection © Tait Limited March 2015...
  • Page 20: Overview Of Inputs And Outputs

    Ethernet The Ethernet interface is used to connect the TD9300 to the RTU/ IED or to the network. It is also used to configure the TD9300 via a web browser. It is a 10BASE-T or 100BASE-T connection. The green link speed LED indicates the negotiated link speed. The LED is lit when the link speed is 100BASE-T.
  • Page 21 RTU Status LED The green RTU status LED is lit when the RTU is linked to the TD9300. DMR LED The green DMR LED is lit when the TD9300 is registered on the DMR network. 1 LED Reserved for future use.
  • Page 22: Interface Pin Allocations

    1 B 1 2 3 4 input 2 A input 2 B output 1 A output 1 B 5 6 7 8 output 2 A external view output 2 B TD9300 Installation Manual Connection © Tait Limited March 2015...
  • Page 23: Connecting Dc Power

    The TD9300 is powered down by disconnecting the front panel DC What about a shutdown connector. process for the Linux console? The pin allocations for the DC input on the TD9300 are given in the following table. Description –V input +V input...
  • Page 24: System Connections

    DRAFT 3 System Connections Example connection diagram to be supplied later TD9300 Installation Manual Connection © Tait Limited March 2015...
  • Page 25: Getting Started

    DRAFT 3 Getting Started Confirming Operation The LEDs on the front and top panels will indicate that the TD9300 is operating correctly. Connect power to the TD9300. Check that the LEDs indicate normal operation, as described below. Color State Power...
  • Page 26 DRAFT 3 TD9300 Installation Manual Getting Started © Tait Limited March 2015...
  • Page 27: Specifications

    Where applicable, the test methods used to obtain these figures are those described in the ETSI-EN specifications. You can obtain further details of test methods and the conditions which apply for compliance testing in all countries from Tait. TD9300 Installation Manual Specifications © Tait Limited March 2015...
  • Page 28: General

    Signal Levels RS-232 and RS-485 compatible Format 8 bit ASCII, 1 stop bit, no parity Baud Rate 1200 to 115,200 bps Ethernet Interface Transceiver 10/100Base-T Indicator LEDs Green speed Orange link/activity TD9300 Installation Manual Specifications © Tait Limited March 2015...
  • Page 29: Digital Inputs And Outputs

    IP51 (dust category 2) - front panel connectors facing down Environmental Low Pressure (Altitude) MIL-STD-810G 500.5 Proc 2 Humidity MIL-STD-810G 507.5 Proc 2 Vibration MIL-STD-810G 514.6 Proc 1 Shock MIL-STD-810G 516.6 Proc 1 TD9300 Installation Manual Specifications © Tait Limited March 2015...
  • Page 30 DRAFT 3 TD9300 Installation Manual Specifications © Tait Limited March 2015...
  • Page 31: Tait Software License Agreement

    “Designated Products” means products pro- vided by Tait; and (iii) may contain one or more vided by Tait to Licensee with which or for which items of software owned by a third-party sup- the Software and Documentation is licensed for plier.
  • Page 32 Tait during the course of the inspec- for use by third parties on a "time sharing," tion will be kept in strict confidence by Tait and "application service provider," "service bureau" used solely for the purpose of verifying...
  • Page 33 Tait demonstrating compli- investigation of the perceived defect reveals that ance with all the foregoing. no such defect in fact exists, Tait may recover its Section 8 TERM AND TERMINATION costs in respect of such investigation from 8.1.
  • Page 34 Tait to the repair or replacement without first obtaining such license or approval. of the Software or the refund of the purchase 11.10.

Table of Contents