WArNING
FIrE or EXPloSIoN HAZArD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT To Do IF You SMEll GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
INSTAllATIoN INSTrucTIoNS
AND oWNEr'S MANuAl
FAN TYPE VENTED
WAll FurNAcE
MoDElS
FAW40IPXlP-1
FAW40IPXNAT-1
INSTAllEr:
Leave this manual with the appliance.
coNSuMEr:
retain this manual for future reference.
WArNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
FAW40SPPXlP-1
FAW40SPPXNAT-1
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire FAW40IPXLP-1

  • Page 1 INSTAllATIoN INSTrucTIoNS AND oWNEr'S MANuAl FAN TYPE VENTED WAll FurNAcE MoDElS FAW40IPXlP-1 FAW40SPPXlP-1 FAW40IPXNAT-1 FAW40SPPXNAT-1 INSTAllEr: Leave this manual with the appliance. coNSuMEr: retain this manual for future reference. WArNING WArNING If not installed, operated and maintained in accordance with the manufacturer's...
  • Page 2 DV-648 combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. coNVErSIoN KITS Model Number Description used on DV1351 Propane to Natural FAW40IPXLP-1 DV1349 Natural to Propane FAW40IPXNAT-1 DV1347 Propane to Natural FAW40SPPXLP-1 DV1345 Natural to Propane FAW40SPPXNAT-1 Page 2...
  • Page 3 INTroDucTIoN (coNT'D) When an existing Category 1 heater is removed or replaced, the improperly sized venting system (formation of condensate, leakage, original venting system may no longer be sized to properly vent the spillage, etc.) and shall specify the following test procedure: attached appliances. Instructions shall also indicate effects of an WArNING Turn on clothes dryers and any appliance not connected cArBoN MoNoXIDE PoISoNING HAZArD...
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INForMATIoN For uSErS oF ProPANE GAS Propane is a flammable gas which can cause fires and explo- SoME PoINTS To rEMEMBEr sions. In its natural state, propane is odorless and colorless. • Learn to recognize the odor of Propane Gas. Your local Propane You may not know all the following safety precautions which Gas Dealer can give you a "Scratch and Sniff"...
  • Page 5: Ventilation And Combustion Air

    Ventilation and combustion Air WArNING: Danger of property damage, bodily injury or death, this furnace and any other fuel burning appliance must be provided with enough fresh air for proper combustion and ventilation of flue gases. Most homes will require that outside opening furnace air be supplied.
  • Page 6: Qualified Installing Agency

    Qualified Installing Agency B. 4" (102mm) oval (all parts purchase locally) Installation and replacement of gas piping, gas utilization equipment or 1. Type B-1 oval pipe or B-W vent pipe accessories and repair and servicing of equipment shall be performed 2. Single story type B-1 or (B-W) gas vents require a baseplate only by a qualified agency. The term "qualified agency" means any and one pair of ceiling plate spacers. individual, firm, corporation or company which either in person or 3. Multi-story type B-1 or (B-W) gas vents require a baseplate, through a representative is engaged in and is responsible for (a)
  • Page 7 boot through the wall and attach side wall plate to furnace side of wall with (2) #10 x 1 1/2" (38mm) provided screws. 5. Attach outer boot to the cabinet side with (4) #8 x 1/4" (6mm) provided screws. 6. Position and attach inner boot to inner shield with (4) #8 x 1/4" (6mm) provided screws.
  • Page 8 8. Align clearance holes on 6" x 10" (152mm x 254mm) duct with Attaching Furnace to Wall screw holes on inner casing back and mark duct to be 2 1/4" When attaching furnace to the wall remove that portion of baseboard (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove and molding on the wall which is behind the furnace.
  • Page 9: High Altitudes

    Attention! If one of the above procedures results in pressures in remove the screws fastening the burner door. After removing the excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, burner door from the burner box, remove each main burner. Pilot it will result in a hazardous condition. mounting bracket will need to be unscrewed and moved out of checking Manifold Pressure the way to remove all burners.
  • Page 10 your protection against shock hazard and should be plugged burners to "shut off" due to improper venting or a blocked flue. directly into a properly grounded three-prong receptacle. Do To reset the manual reset vent safety switch: not cut or remove the grounding prong from this plug. For an 1. Remove front panel. ungrounded receptacle, an adapter, which has two prongs and a 2.
  • Page 11: Pilot Flame Adjustment

    SErVIcE AND MAINTENANcE SuGGESTIoNS 3. Replace the cover screw after the adjustment to prevent gas cALL SERVIcEMAN leakage. GENErAl: All furnaces have been fire-tested to check for proper PRESSURE REGULATOR operation. This includes, main burner flame, pilot flame, fan operation, ADJUSTMENT-UNDER CAP OUTLET PRESSURE TAP SCREW fan control, limit control and valve operation. If the furnace fails to function on initial installation, it is advisable to re-check the following: 1.
  • Page 12: Standing Pilot -Lighting Instructions

    STANDING PIloT -lIGHTING INSTrucTIoNS For Your SAFETY rEAD BEForE oPErATING WArNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which •...
  • Page 13 INTErMITTENT PIloT (IP) -lIGHTING INSTrucTIoNS For Your SAFETY rEAD BEForE oPErATING WArNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which C.
  • Page 14: Sequence Of Operation

    SEquENcE oF oPErATIoN Apply 24 VAC START To Appliance Call for Heat 5 Minute Retry Delay Pilot Valve Ignition OFF Flame Signal Wait for Flame Signal to Detected Disappear System Check Internal Check Trial for Pilot Valve Opens Ignition Ignitor Powered Pilot Light and Flame is Pilot Valve Closes Sensed During Trial For...
  • Page 15 START IP SYSTEM TROUBLESHOOTING SEQUENCE Turn OFF Gas Supply INSET A End View Disconnect System Control SmartValve System Troubleshooting Sequence of Control Harness Note: Before Troubleshooting, Become Familiar Harness Connector Set Gas Control to Call for with the Sequence of Operation 24 Volt Heat Output...
  • Page 16 PlEASE NoTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PArT INDEX PArT DEScrIPTIoN DEScrIPTIoN WFA115 GASKET - hEADER R5655 GAS VALVE - PROPANE (SPP) DV1247 TOP PLATE (USA) R2148 GAS VALVE - NATuRAL (SPP) 15668 TOP PLATE (cANADA) R3170 GAS VALVE - NATuRAL (IP) R3165 DOOR CLIP (2 REQUIRED) R3171 GAS VALVE - PROPANE (IP) 39476...
  • Page 17 37134-4-0319 Page 17...
  • Page 18: Master Parts Distributor List

    MASTEr PArTS DISTrIBuTor lIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the fireplace.
  • Page 19: Warranty

    WArrANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual. This warranty applies to the original purchaser only and is not transferable. All warranty repairs must be accomplished by a qualified gas appliance technician.
  • Page 20 Empire comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 20 37134-4-0319...