12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 1. Introduction. We congratulate you on the excellent choice! Do not leave this instruction manual unread. Installation and operation of a pellet stove associated with various legal obligations, which are explained in this instruction manual.
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 Technical data and nominal performance: Performance parameters: Technical data Vittoria 8 Vittoria 10 Nominal heat output 6.1 kW 8.0 kW Reduced heat output 3.0 kW 3.7 kW...
Victoria-05 Ltd. 5. Control unit. The control unit is equipped with a system for monitoring and controlling of the burning process. It ensures higher efficiency, optimizes the fuel consumption and minimizing the emissions. With sensors for the pressure in the fire chamber and temperature sensors at the flue outlet for the temperature of the flue gasses, the system analyzes the collected data from the burning and automatically controls it and optimizes it.
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 The initial ignition of the pellets is carried out by hot air, which is sucked in around the ignition (K) in the combustion chamber through the fume extractor (G). Fume extractor provides combustion air by sucking in from air inlet Ø40 mm (D) by the room or by outside atmosphere.
Victoria-05 Ltd. 9. Appliance installation. Trained and competent technicians or companies must perform the installing a pellet stove! Qualified technicians should perform all activities in inspection and repair of electrical components. Switch off the pellet stove from the electric supply before any inspection or repair! Refer to the regulations valid for the country, where the pellet stove will be used, if you do not find the information you are interested in this instruction manual.
Before ignition, check: power, door seal, if the combustion chamber is cleaned and whether the display is switched to standby mode. 10.2. Control panel description After start up, on the control display is shown the logo of Victoria-05 for 3 seconds and then switches to main user panel. The icons and functions are shown as follows: Picture.4.
Victoria-05 Ltd. 10.2.1. Main user control panel. To visualize every function from the display it is necessary to touch the respective icon. The blue arrow in the sub menu is for returning to the previous screen. By pressing SAVE all corrections are saved. The left and right arrows are for decreasing and increasing the value of the respective parameter.
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 10.2.3. Main menu. Air correction ±15% sets in percentage the adjustment of the power of smoke during operation mode and the pause length of the feed screw.
2468.After that access have to be touched to unlock the display. 10.2.4. Installer settings. Factory settings Types of settings for Installer (entered with installer password) Vittoria 8 Vittoria 10 Duration 700 sec. 700 sec. 55 %...
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 From this menu, the default language can be set. – Bulgarian, English, Netherlands, Deutsch. 10.2.5. Service technician settings. Types of settings for service technician (entered with...
Victoria-05 Ltd. Indoor fan- we can choose between 1%to 100%.Choosing from 1 to 100 and then safe, at the exit of the indoor fan OUT3 is triggered modulation of the power. 10.3. Cold test. The cold test is necessary to check the working order and proper connection of electrical components in the pellet stove. The test of the outputs is possible only in ready mode.
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 In Modulation mode, by touching the field showing the current modulation, we can change and set the modulation preset that we like. If the stove is working in P3 and we touch the field, the preset will change to P2. If touched again, it will change to P1.
Victoria-05 Ltd. Check sensors; Check and, if necessary, replace the battery on the control panel; Clean and check the electronic control system; Check all electrical cables; Clean the pellet fuel hopper and check auger for loosen screw and the gear motor;...
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10 Activated timer Red color: the timer is activated and waiting for the set time to stop the stove. Activated timer Green color: the timer is activated and waiting for the set time to start the stove.
Victoria-05 Ltd. Yes, at least once a month or if the pellet stove has not worked for a long time. Can you use other types of fuel than wood pellets? NO. Pellet stove is designed to work with wood pellets with a diameter of Ø 6 mm. The use of another type of fuel leads to damage.
Page 19
12.2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10...
Failing that provided, the claim is not accepted as valid and the buyer pays repair. On the territory of Bulgaria the term of the removal of the claim is up to three (3) days for settlements in which Victoria-05 Ltd.
Need help?
Do you have a question about the VITTORIA 8 and is the answer not in the manual?
Questions and answers