Weelko F-330 Instruction Manual

5 in 1 magic glove bio skin smoother high frequency ultrasound galvanic
Hide thumbs Also See for F-330:

Advertisement

5 IN 1
Magic Glove
Bio Skin Smoother
High Frequency
Ultrasound
Galvanic
MultiEquipment. Ref F-330
Instruction manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-330 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Weelko F-330

  • Page 1 MultiEquipment. Ref F-330 Instruction manual 5 IN 1 Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic...
  • Page 2 Barcelona Pol. Ind. La Valldan Camí de Garreta, 86 08600 Berga Barcelona – Spain T. +34 902 041 563 E. info@weelko.com W. www.weelko.com...
  • Page 3: Front Panel

    Front panel function State Energy Timer select F-330 4 in 1 beauty Start/Pause instrument Instructions of use SKIN SCRUBBER 1. Connect the power supply via the rear panel. 1. Place the bracelet around the customer’s wrist. 2. Connect the accessories properly to the front/rear 2.
  • Page 4: Starting Treatment

    ULTRASOUND Cautions Before treatment • Never use on dry skin. 1. Cleanse/tone the treatment area using the • Do not use on the stomach area of pregnant women. prescribed skin-type products. • Do not use on people with pace-makers (any 2.
  • Page 5 GALVANIC Cautions Before treatment • Always make sure customers remove any jewelry, and confirm that they have not had any metal implants 1. The treatment area must be washed and dried (pins, joints, etc.) installed since their last treatment. before any products can penetrate into the tissue. •...
  • Page 6 MAGIC GLOVES Cautions Instructions of use • Pacemaker (any electrical or rhythmic heart-regulating device) 1. Connect ones side of the wire in the rear panel, in the plug named “BIO WAVE MICROCURRENT”. • Pregnancy 2. Connect the other two sides of the wires in each •...
  • Page 7 BIO-LIFTING Instructions of use Skin scrubber 1. Connect ones side of the wire in the rear panel, in The probe suddenly stops emitting: the plug named “BIO WAVE MICROCURRENT”. • 2. Connect the other two sides of the wires in the If the probe is separated from the skin, it will stop handles of BIO-lifting.
  • Page 8: Maintenance

    MAINTENANCE Galvanic Skin scrubber • Take care not to damage the probe rollers. Never use abrasive substances to clean the probe rollers, since • damage to the surface of the roller may scratch the Any oil on the probe must be removed immediately. surface of the skin during treatment;...