A.6.2 SPECIFICATIONS

A.6.2.1 Heat Pump (Refrigerant R407C)

Item
Function
Capacity
Total input
Model name
Power supply (phase, cycle,voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan (drive) o No.
Fan motor output
Fan
Air flow (Lo-Mi2-Mi1-Hi)
External static pressure
Booster heater
Operation control & Thermostat
Noise level (Lo-Mi2-Mi1-Hi)
Unit drain pipe I.D.
Dimensions
Weight
Model name
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan (drive) o No.
Fan
Fan motor output
Air flow
Crankcase heater
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor units
NOTE:
1. Rating conditions (ISO T1)
Cooling : Indoor
: D.B. 27: (80˚F), W.B. 19: (66˚F)
Heating : Indoor : D.B. 20: (68˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
CEILING CASSETTE PM SERIES Heat Pump R407C PMH-P1BA
Model
Btu/h
W
kW
kW
A
A
Galvanized sheets with gray heat insulation, grille munsell 0.98Y 8.99/0.63
kW
K / min (CFM)
Pa (mmAq)
kW
dB
mm (in.)
W
mm (in.)
D
mm (in.)
H
mm (in.)
kg (lbs.)
kW
A
A
kW
kW
K / min (CFM)
W
Cooling
dB
Heating
dB
W
mm (in.)
D
mm (in.)
H
mm (in.)
kg (lbs.)
kg (lbs.)
L
Liquid
mm (in.)
Gas
mm (in.)
Indoor side
Outdoor side
Height difference
Piping length
Outdoor
Outdoor
Indoor
Outdoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
D.B. 28˚C
D.B. 24˚C, W.B. 18˚C
D.B. 17˚C
D.B. -11˚C, W.B. -12˚C
PMH-P1BA
Cooling
10,700
3,150
1.15
PMH-P1BA
Single phase, 50Hz, 220-230-240V
0.04
0.19
0.21
Plate fin coil
Line flow fan (direct) o 1
0.028
6.3-6.8-7.6-8.4 (222-240-268-297)
0 (direct blow)
Remote controller & built-in
29-31-33-35
26 (1)
UNIT : 812 (31-31/32) PANEL : 1000 (39-3/8)
UNIT : 395 (15-9/16)
PANEL : 470 (18-1/2)
UNIT : 230 (9-1/16)
PANEL : 30 (1-3/16)
UNIT : 14 (31)
PANEL : 3.0 (6.6)
PUH-P1VGAA
Single phase, 50Hz, 220-230-240V
1.11
4.92
30
Munsell 5Y 7/1
Linear expansion valve
Hermetic
RE189VHSMT
0.9
Line start
Internal thermostat, HP switch, Discharge thermo.
Plate fin coil
Propeller (direct) o 1
0.070
45 (1,590)
30
Reverse cycle
46
48
900 (35-7/16)
330+20 (13+3/4)
650 (25-5/8)
50 (110)
R407C
1.7 (3.7)
0.57 (Ester) MEL56
6.35 (1/4)
12.7 (1/2)
Flared
Flared
Max. 30m
Max. 30m
: D.B. 35: (95˚F), W.B. 24: (75˚F)
: D.B. 7: (45˚F), W.B. 6: (43˚F)
3. Above data based on indicated voltage
Indoor unit
Single phase 240V 50Hz
Outdoor unit
Single phase 240V 50Hz
Heating
11,600
3,400
1.06
1.02
4.52
A-283