Normal Keypad Operation; Keying Indication Summary - Mighty Mule MMKPD Instruction For The Installation

25 code digital keypad

Advertisement

Normal Keypad Operation:

• If the user enters a 4-digit code that is matched to one of the 25 stored codes. The STATUS light should
blink rapidly indicating that it is sending command to operator.
• No more than 20 key presses are allowed to obtain the 4-digit entry code.
Example:
1234 is one of the codes stored in one of the memory location.
The user can enter "x1234" or "xxxxxxxxxxxxxxxx1234" and the gate should be activated (x is any key).
If more than 20 key presses is entered without matching one of the codes then the unit's STATUS light
should be flashing rapidly and no entry will be accepted for the next 40 seconds. The user must not enter
any code for at least 40 seconds before the unit returns to normal operation; otherwise it remains in this
"lock-down" mode. Once the user enters a matched code, any subsequent key press within the next 40
seconds will cause the keypad to send command to gate opener.

Keying Indication Summary:

Master Code Setting
Permanent Entry Code
Temporary Entry Code
Setting
Entering Entry Code
Keying Error Alert Indication
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Keying accepted confirmation Indication
Speaker: Beep – Beep – Beep
STATUS light: 3 flashes along with beeps
Speaker: Beep – Beep – Beep
STATUS light: 3 flashes along with beeps
Speaker: Beep – Beep – Beep
STATUS light: 3 flashes along with beeps
Speaker: Beep – Beep – Beep
STATUS light: 3 flashes along with beeps
40 seconds after entering code