UNIDATA
2.6.1
Battery Status LEDs
The top two indicators (labelled BATTERY) show the internal battery status
(see Battery Status Indicators on page 20).
2.6.2
Scheme Status LEDs
When the PROLOGGER has been programmed with a Scheme (using
Version 2 Software) the lower two indicators show the status of the Scheme
operation.
LED On
Waiting to be unloaded.
None
Waiting for input signals to be connected.
Connected to signals and waiting to begin
Green
logging.
Green & Red
Actively recording.
Red
(No Scheme loaded.)
2.7
The Display and Keyboard
The PROLOGGER has a 64 character Liquid Crystal Display (LCD) and an
eight key operator keyboard.
The Display may be activated by pressing the ON key. The Display will turn
OFF automatically after a delay of 20 seconds (when no further keys have
been pressed).
While the Display is active, the PROLOGGER is in high power mode and
uses about 100 times more battery power than in normal scanning mode.
8 PROLOGGER OVERVIEW
Description
State
Stopped
Primed
Primed
Logging
(Invalid)