Two-way converter of phone line to gsm with built-in gsm module (28 pages)
Summary of Contents for Level GB 200
Page 1
GSM GATE PROFESSIONAL Set GB 200 with Built-in GSM Module Two-way Converter of Phone Line on GSM USER GUIDE LEVEL...
Page 2
Dear customers, we would like to congratulate you on buying our product – GSM Gate GB 200. This way you obtained high-class and technically highly modern product. GSM Gate by LEVEL allows significant phone costs savings as well as installation of phone line even in place where it otherwise would not be possible.
List of Programming Instructions. Subsidiary Programs for PC. 8.1. Installation. 8.2. GB200cfg - Program for Configuration of GB 200 from PC. 8.3. GBserver - Program for Distribution of SMS Messages. 8.4. GBsms - Program for Reception and Dispatch of SMS Messages.
1. Description and Usage of Product. GSM Gate GB 200 is two-way converter of classic phone line for calls to cell phone GSM network. At the same time device allows dispatch of prepared SMS messages on the basis of changes in voltage on inputs and evaluation of incoming SMS messages for set-up of outputs.
SIM card at start-up of communication with GSM module if blocking of SIM card by PIN is active. SIM card shall be inserted under sliding lid on left down corner of GB 200. Gently press the lid inside and down at its upper end.
It is carried out by dialling of numbers on phone line by phone with frequency dialling. Pick up receiver. If you have GB 200 271, dial extension number, on which gate is installed. You will hear dialling tone of GSM gate.
“”. 5. Control Instructions. All parameters of GB 200 can be set from PC through serial line, by phone in programming regime or by texts of instructions in SMS messages, which follow after XXpppp. 5.1. PIN in GSM Gate GB 200.
If you do not know PIN of GSM gate carry out hardware initialisation – see chapter 4.17. It is not possible to program gate by SMS messages if PIN SIM in gate is not conformable to PIN of SIM card. Login of gate in GSM network is then not carried out. This is e.g. state after initialisation.
After occupation of transmitter some exchanges cause glimmer of line, which could be evaluated as number by GSM gate. This function allows setting of delay after moment of pick-up. During this delay situation on line will be ignored. Function only for GB 200 171. Instruction by Phone...
5.8. Set-up of Waiting Time for Dial. After picking up GSM gate gives you dialling tone, which notifies you about possibility of dialling of number. After set time dialling tone changes to engaged tone and reading of dialled phone number is terminated. Instruction by Phone SMS Instruction Pre-set...
If function is active and SMS messages are though not read from GB 200 by PC it can mean that SMS memory in GB 200 is full. Further SMS messages are then not accepted and it might therefore happen, that control instruction included in SMS message is not carried out.
5.17. Switch-on of SIM Card. All function related to particular SIM card can be switched off by this parameter regardless of other set-up. GB 200 will never try to switch over to switched-off SIM card. Instruction by Phone SMS Instruction Pre-set 1601z#...
Not to forfeit credit of GO card, EUROTEL requires to carry out at least one paid phone connection in 3 months from this card. So that user, which uses GB 200 for protection of properties, does not have to think of this matter it is possible to enter number, which gate automatically calls each month of operation, in GB 200.
GB 200 does not use real time and call can come during night. 5.23. ALARM SMS Messages and Set-up of A-numbers for SMS Despatch. 8 input/output signals are taken out on connector CANNON 15 of GB 200 (outlets No.1 - 8) One of eight prepared texts can be dispatched in...
5.25. Set-up of Numbers for ALARM Calling. Particular set phone number will be dialled simultaneously to activation of input No. 1 to 8 and called party will hear warning tone from GB 200 after pick-up. Instruction by Phone SMS Instruction Pre-set 240vn#...
5.29. RESET of Gate and Time Counters. It is possible to carry out remote RESET of GB 200 by means of SMS message. Action is equivalent to switch-on of charging tm. start-up of program, switch-off and on of GSM module and login in network.
7. List of Programming Instructions. Switch-over into programming regime is carried out by dialling #pppp# on phone line. Code XXpppp must forgo instructions in each control SMS message. pppp is PIN of GSM Gate. By phone SMS instruction Initial Instruction Range #pppp# …...
Page 19
By phone SMS instruction Initial Instruction Range #pppp# … XXpppp … values SMS message into PC 1500z # HOSTSMS z z = 0 off, 1 on through RS 232 Switch-on of SIM1 1601z # SIMON1 z z = 0 off, 1 on Switch-on of SIM2 1602z # SIMON2 z...
Edit of all parameters of GB 200. Opening/ saving of configuration from file / in file and from GB 200 / into GB 200. Set-up of communication port for GB 200. Display of level of GSM signal.
9. Basic Technical Parameters. Line GB 200 171 Dialling of number Dial pulse or tone dialling Line voltage 48 V Ringing 35 Vef. 50Hz - 1s / 4s Tones 425 Hz Impulse 16 kHz 16000Hz ±0,1%, 35 ms, min. 150mV...
GUARANTEE CERTIFICATE Product name: Type : Production number: Date of sale: Signature: Selling organisation: Address, phone No., stamp: Date of Date of Description of defect receipt dispatch...
Guarantee repair will be carried out at latest within 10 working days after receipt of defective goods by company LEVEL provided that spare part is disposable in store. If it is not possible alternative solution will be offered to user for the time of repair.