PF-SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: OPERATING/FILTERING INSTRUCTIONS
4.1 Filter Operation
Use care when draining and filtering oil to avoid the possibility of a serious burn.
1. Sprinkle 8 ounces (1 cup) of filter powder over the filter paper, distributing the powder as evenly
as possible. If filtering a second frypot immediately after the first, add only 4 ounces of filter
powder for the second filtering.
2. Ensure the power cord is securely plugged into the receptacle on the back of the portable filter
Plug the power cord into an 115V receptacle.
3. If solid shortening is filtered through the portable filter, turn the Heater/Filter switch to HEATER
(see illustration below. The white indicator light will illuminate. Leave the heater on for 20-30
minutes before operating the filter.
Use the filter heater for 20-30 minutes prior to filtering if solid shortening is filtered.
Note: The filter pump cannot be activated while the switch is in the "Heater" position.
4. Ensure the Suction/Off/Return switch is OFF. Turn the Heater/Filter switch to FILTER for filter
operation (see illustration below). The red indicator light will illuminate.
The Heater/Filter switch must be in the FILTER position before the filter pump can
be operated. The red light will illuminate when the switch is properly positioned.
WARNING
4-1