O2X DUO
Dissolved Oxygen
Sensor
2018-11-20
C14D5EN19

Advertisement

Table of Contents
loading

Summary of Contents for Cerlic O2X Duo

  • Page 1 O2X DUO Dissolved Oxygen Sensor 2018-11-20 C14D5EN19...
  • Page 2: Table Of Contents

    A few words about this manual Design Measuring principle Unpacking the sensor Packaging ......................4 Content ......................4 Optional parts for O2X DUO: P/N ............4 Mounting the sensor Cable Connections ..................... 5 Installation Tips ....................5 Removing the sensor Changing or installing a new electrode/cell Removing an old electrode/cell: ................
  • Page 3: Introduction

    The Clark & Optical cells can be interchanged in the O2X DUO sensor but an air calibration must be preformed. There is a connector on the electrode for the O2X amplifier cable.
  • Page 4: Unpacking The Sensor

    Damages If damages occurred during shipment, immediately contact the forwarder as well as your Cerlic representative. The shipment can be returned only after contact has been made with Cerlic. Packaging The original packaging is designed to protect the equipment and should be used for storage or if the goods must be returned.
  • Page 5: Mounting The Sensor

    Dielectric paste can be applied to the connector for corrosion protection. The O2X DUO sensor is mounted on a telescopic fibreglass rod and placed in a mounting bracket that fastens to a handrail, please refer to the Appendix 1 for further details.
  • Page 6: Removing The Sensor

    Removing the sensor The SS sensor housing may not be opened except by Cerlic service personnel. Opening the sensor housing will void factory warranty. The sensor is removed in the following steps: • Disconnect the sensor cable from the BB1/BB2 control box and the flushing hose from the solenoid.
  • Page 7: Installing A New Electrode/Cell

    • If a new electrode is not to be installed, then the yellow plastic cap shall be mounted to protect the electrode connection plug and the flushing nozzles on the sensor. Installing a new electrode/cell: • Loosen and remove the SS flushing head. •...
  • Page 8: Cleaning The Sensor

    Flushing Flushing tube Sensor cable • Select the O2X DUO sensor in the Main Menu by using the buttons, • Press ENTER for five seconds to enter the Sensor Menu. • Use the arrows to select “Cleaning” and press ENTER.
  • Page 9: Cleaning The Flushing Nozzle

    By simultaneously pressing and ENTER you change between BB1/BB2 main menu and the sensor information display for the selected sensor. O2X DUO sensor has two information displays, the first menu shows: measured DO value, current temperature of the electrode in air, the solubility DO value in air for this air temperature, and the “slope”...
  • Page 10: Menu For O2X Duo Sensor

    10. Menu for O2X DUO Sensor to select the sensor on the main display. The menu for the selected sensor is accessed by pressing ENTER for five seconds. If the selected sensor is not active (the text No transmitter is shown) a warning is displayed that asks you to make another choice in order to show the sensor menu.
  • Page 11: Cleaning

    Cleaning Press ENTER to go to Cleaning program Cleaner ”None”, ”Flush”, or ”Brush”. Do not select “Brush” since this does not exist for the O2X sensor Interval min 0--999 minutes, time between cleaning cycles Length sec 0--999 seconds, duration of flushing cycle Freeze sec 0--999 seconds, extra freeze time of output signal after a flushing cycle so sensor can go back to the orginal values.
  • Page 12: Calibration

    11. Calibration It is important that the instrument has been turned on for about 30 minutes prior to calibration so that the sensor and electronics can stabilize. Zero Calibration The sensor is zero calibrated at the factory, and does not need to be zero calibrated. We do however recommend to do a new zero calibration when replacing the electrode since half the job is then already done.
  • Page 13: Air Calibrating A Sensor

    An open plastic bag over the sensor may slow the calibration time down, but is otherwise a good way to help maintain constant conditions. • Select the O2X DUO sensor in the Main Menu by using the buttons.
  • Page 14: Air Pressure Conversion

    Air pressure conversion It is important to enter the correct air pressure before doing an air calibration. Air pressure is measured in mBar (which is exactly the same as the SI-unit hPa). Below is a formula and a table to convert from inHG to mBar (and thus to hPa). InHg mBar / hPa 29.2...
  • Page 15: Technical Description

    Enclosure IP68 (NEMA 4X) Certificate of conformity: The O2X DUO sensors along with their central unit BB1/BB2 Control Box are in conformance with the following EC Directive(s) when installed in accordance with the installation instructions contained in the product documentation:...
  • Page 16: Dimensions

    EMC Directive SS-EN 61000-6-2 Edition 3:2005 Electromagnetic compatibility – Part 6-2: Generic standards – Immunity for industrial environments. SS-EN 61000-6-4 Edition 2:2007 Electromagnetic compatibility - Part 6-4: Generic standards – Emission standard for industrial environments. 14. Dimensions Appendix 1, Assembly of handrail mounting kit Mount the Flexible Mounting Bracket on handrail diameter of 1 ¼”...
  • Page 17 Example of a handrail when no handrail is available. • Disassemble the plastic Rod guide and place around the telescopic rod. • Use the SS screws on bracket to tighten the bracket to the rod. • Pull the M12 cable and flush hose through the sensor holder and rod. •...
  • Page 18: Appendix 2, Assembly Of Adjustable Slide Rail

    Appendix 2, Assembly of adjustable slide rail...
  • Page 19: Appendix 3, Support Information

    Appendix 3, Support information Before calling Cerlic support, please complete the information in this form and have it ready. Company Name Phone E-mail Sensor Type Position / Tag First go to the BB1/BB2 menu, it is accessed by pressing and ENTER at the same time for five seconds.
  • Page 20: Appendix 4, Setup Information

    Appendix 4, Setup information This sheet can be used to document the setup values of an O2X sensor. Sensor Type Position / Tag In the System sub menu of the sensor menu the following information can be collected. Serial SoftW In the Settings sub menu of the sensor menu the following parameters can be set.