Ver. 00 ® Although every effort is made to keep this document accurate and up to date, MagneMotion assumes no responsibility for any errors, omissions, or inaccuracies. Information that is provided in this document is subject to change without notice. Any sample code that that is referenced in this document or included with MagneMotion software is included for illustration only and is, therefore, unsupported.
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Contents About This Addendum ......................5 Purpose ..........................5 Audience ..........................5 Prerequisites ........................5 Reference Documents ......................5 Introduction ..........................6 Overview ..........................6 Air-cooled Motor Overview ....................6 Safety ............................
Page 4
Figures Figure 1: Detailed View of the 1000 mm MM LITE Air-cooled Motor ........6 Figure 2: Locations of Labels on the MagneMover LITE Straight and Curve Motors .... 8 Figure 3: Air-cooled Motor Option..................10 Figure 4: 1000 Millimeter Air-cooled Motor Mechanical Drawing ........11 Figure 5: Air-cooled Motor Pneumatic Connections ..............
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 About This Addendum This document is an addendum to the MagneMover LITE User Manual and describes the air- cooled motor option. Purpose ® This document explains how to install, operate, and maintain the MagneMover LITE (MM ™...
The motor is delivered with plugs installed in the ports, which allows the motor to be used as a standard MagneMover LITE motor. The plugs must be removed and one-touch fittings installed to use the air-cooled option.
See the MagneMover LITE User Manual for all regulatory compliance information. Safety Considerations See the MagneMover LITE User Manual for all personnel and equipment safety information. Symbol Identification See the MagneMover LITE User Manual for all symbol identification and use information.
Air-cooled Motors 10003676721 Ver. 00 Mechanical, Electrical, Magnetic Hazards See the MagneMover LITE User Manual for detailed hazard and safety information. CAUTION Crush/Pinch Hazard Moving mechanisms have no obstruction sensors. Do not operate the MagneMover LITE components without barriers in place or personal injury could result in the squeezing or compression of fingers or other body parts between moving mechanisms.
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Design Guidelines Overview The primary benefit of cooling the motor is that heat that is generated from motor operation can be quickly removed from the motor with convection, thus allowing larger continuous current and power draw.
The exclusion zones that are shown are for the MM LITE motor only. Additional exclusion zones may be required based on the use of the motor. See the MagneMover LITE User Manual for the electrical specifications. Exposed Materials • 316/316L Stainless Steel.
MagneMover LITE User Manual. Pneumatic Specifications The MagneMover LITE air-cooled motors are designed to allow a continuous flow of clean, dry air to provide additional cooling. These motors can be run as normal MM LITE motors by installing the supplied 3/8 in plugs in the port locations.
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Environmental Requirements Motors Temperature: Operating: 0° C to 50° C [32° F to 122° F] Shipping: -18° C to 50° C [0° F to 122° F] Storage: -18° C to 50° C [0° F to 122° F]...
Ver. 00 Installation Unpacking and Moving The MagneMover LITE air-cooled motors arrive from the factory as a component ready for final installation. The information that is required to install these components is provided in the MagneMover LITE User Manual. Installing Pneumatic Lines for Pressurizing A pressurized air line supplying clean, dry air is run to the system and then distributed to all motors that require pressurization.
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Maintenance Preventive Maintenance Table 3: MagneMover LITE Air-cooled Motor Preventive Maintenance Schedule Component Maintenance Action Frequency* Page # Motor Verify that the air supply is correct pressure and 3 months or...
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Pneumatic System PM The pneumatic system that supplies air to the motors must be checked periodically to verify it is operating properly. See the documentation that is supplied with the equipment by the manufacturer.
MagneMover LITE User Manual Addendum, Air-cooled Motors 10003676721 Ver. 00 Rockwell Automation Support Use the following resources to access support information. Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User https://rockwellautomation.custhelp.com/ Forums, and Product Notification Updates. Local Technical Support Phone Numbers Locate the phone number for your country.