Masibus 9000L Series Manual

Masibus 9000L Series Manual

Isolated converter

Advertisement

INDEX
A
E
PPLICATION
XAMPLE
S
PECIFICATION
...............................................................................................................
S
AFETY AND WARNING
C
ONNECTION
..................................................................................................................
I
NSTALLATION
.................................................................................................................
O
RDERING CODE
............................................................................................................
T
ROUBLE SHOOTING
9000L
................................................................................................
...................................................................................................
......................................................................................................
Doc.Ref.No.:m92A/om/101-1
Issue No.:02
1
2
3
3
3
4
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9000L Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Masibus 9000L Series

  • Page 1 9000L Doc.Ref.No.:m92A/om/101-1 Issue No.:02 INDEX PPLICATION XAMPLE …………………………………………………………………………………… PECIFICATION ………………………………………………………………………………………………… AFETY AND WARNING ……………………………………………………………………………………... ONNECTION …………………………………………………………………………………………………… NSTALLATION ………………………………………………………………………………………………….. RDERING CODE ……………………………………………………………………………………………… ROUBLE SHOOTING …………………………………………………………………………………………...
  • Page 2 • Equipped with Advanced Extended Power Supply Range of 20V to 265V AC or DC. • 9000L Series isolators acts as signal distributor when used with dual outputs. • 9000L Offers good accuracy and stability delivering reliable operation in hostile environments with full 3 port isolation between input, output and power supply.
  • Page 3: Specification

    9000L Doc.Ref.No.:m92A/om/101-1 Issue No.:02 Dimensions PECIFICATION Input Input Type Current/Voltage 9000L SOP/ DOP Input Range 4 to 20mA or 0 to 10V Current I/P ≤100Ω Voltage I/P ≤ 1MΩ Input Impedance Output Output Type Current/Voltage Output Range 4 to 20mA or 0 to 10V Output Load Current O/P ≤...
  • Page 4: Safety And Warning

    9000L Doc.Ref.No.:m92A/om/101-1 Issue No.:02 AFETY AND WARNING Block Diagram and connection details of DOP. To ensure that the device can be operated safely and All function can be used, please read these instructions Carefully before installing the device. Caution: Never carry out work when the Power Is turned on, this is dangerous.
  • Page 5: Troubleshooting

    Gandhinagar-382044, Gujarat, India are not as per terminal details. Ph: 91-079-23287275 / 76 / 77 / 78 / 79 Fax: 91-079-23287281/ 82 Email: support@masibus.com One must take care while dealing with Power Web: www.masibus.com wirings because it may create electrical shock...

This manual is also suitable for:

9000l m9000l s

Table of Contents