Masibus 9000U+ SERIES Manual

Masibus 9000U+ SERIES Manual

Isolated converter

Advertisement

INDEX
A
E
PPLICATION
XAMPLE
S
PECIFICATION
...............................................................................................................
S
AFETY AND WARNING
C
ONNECTION
..................................................................................................................
I
NSTALLATION
.................................................................................................................
O
RDERING CODE
............................................................................................................
T
ROUBLE SHOOTING
+
9000U
................................................................................................
...................................................................................................
......................................................................................................
Doc.Ref.No.:m92A/om/101
Issue No.:20
1
2
3
3
3
4
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9000U+ SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Masibus 9000U+ SERIES

  • Page 1 9000U Doc.Ref.No.:m92A/om/101 Issue No.:20 INDEX PPLICATION XAMPLE …………………………………………………………………………………… PECIFICATION ………………………………………………………………………………………………… AFETY AND WARNING ……………………………………………………………………………………... ONNECTION …………………………………………………………………………………………………… NSTALLATION ………………………………………………………………………………………………….. RDERING CODE ……………………………………………………………………………………………… ROUBLE SHOOTING …………………………………………………………………………………………...
  • Page 2 9000U Doc.Ref.No.:m92A/om/101 Issue No.:20 9000U SOLATED ONVERTER ERIES • 9000U Series are compact yet rugged 4 wire Signal isolators designed for conditioning and safe guarding custom-built wide range of voltage and current field signals. Field Signal is then SOP & DOP isolated and converted to standard instrumentation signals, acceptable to commercially off the shelf (COTS) automation products.
  • Page 3 9000U Doc.Ref.No.:m92A/om/101 Issue No.:20 Dimensions PECIFICATION Input Input Type Voltage/ Current 4 to 20mA for Standard 9000U SOP/ DOP 0/4 to 20mA , 0/1 to 5V, 0 to 10V For ‘M’ version Factory settable Input as per user Input Range requirements are: For Voltage : Min: 0 to ±10mV, Max: 0 to ±600VDC...
  • Page 4 9000U Doc.Ref.No.:m92A/om/101 Issue No.:20 AFETY AND WARNING Block Diagram and connection details of DOP. To ensure that the device can be operated safely and all function can be used, please read these instructions carefully before installing the device. Caution: Never carry out work when the Power Is turned on, this is dangerous.
  • Page 5 Make noise away from signal isolator. Fluctuation in Reading The reason can be reverse input connections. masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector- 25, Gandhinagar-382044, Gujarat, India Ph: 91-079-23287275 / 76 / 77 / 78 / 79 Fax: 91-079-23287281/ 82 Email: support@masibus.com...

This manual is also suitable for:

9000u+ m9000u+ s

Table of Contents