③ Below 15 RPM output speed, oil level must be adjusted
NOTE: If reducer position is to vary from those shown in Figure 1 either more or less oil may be required. Consult Dodge Product Support.
Output
RPM
1
301-400
320
320
201-300
320
320
151-200
320
320
126-150
320
320
101-125
320
320
81-100
320
320
41-80
320
320
11-40
320
320
1-10
320
320
Output
RPM
1
301-400
220
220
201-300
220
220
151-200
220
220
126-150
220
220
101-125
220
220
81-100
220
220
41-80
220
220
11-40
220
220
1-10
220
220
For reducers operating in ambient temperatures between -22°F (-30°C) and 20°F (-6.6°C), use a synthetic hydrocarbon lubricant. 100 ISO grade or AGMA 35 grade (lor
NOTE: Pour point of lubricant selected should be at least 10'F lower than expected minimum ambient starting temperature. Refer to Viscosity Equivalency chart for lubricants
viscosity classification equivalents.
Special lubricants may be required for food and drug industry applications where contact with the product being manufactured may occur. Consult a lubrication manufacturers
representative for his recommendation.
Volume of Oil Required to Fill Reducer to Oil Level Plug
➀ Position B
Fluid
Quarts
Fluid
Liters
Ounces
Ounces
➁
(Approx)
(Approx)
(Approx
(Approx)
)
24
3/4
.71
20
28
7/8
.83
28
Table 2 -Lubrication Recommendations -ISO Grades ①