ABB ISO TX 6k User Manual
ABB ISO TX 6k User Manual

ABB ISO TX 6k User Manual

For powervalue rt g2 ul 5-10 kva

Advertisement

Quick Links

U S E R M A N UA L
ISO TX
for PowerValue RT G2 UL 5-10 kVA
PREPARED: Elvan Chen
APPROVED: Patricia Kuenzle
OWNING ORGANIZATION:
ABB Switzerland Ltd.
© Copyright 2022 ABB. All rights reserved.
STATUS
Approved
DOCUMENT KIND: Operating manual
DOCUMENT ID: 4NWD005663 REV: A
SECURITY LEVEL: Public
PAGE:
1 / 18
LANG: EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISO TX 6k and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ABB ISO TX 6k

  • Page 1 PowerValue RT G2 UL 5-10 kVA STATUS PREPARED: Elvan Chen Approved SECURITY LEVEL: Public APPROVED: Patricia Kuenzle DOCUMENT KIND: Operating manual OWNING ORGANIZATION: PAGE: 1 / 18 ABB Switzerland Ltd. DOCUMENT ID: 4NWD005663 REV: A LANG: EN © Copyright 2022 ABB. All rights reserved.
  • Page 2: Table Of Contents

    5.2 Transfer to UPS Protection ....... . . 12 Specification STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 2 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 3: Important Safety Instructions

    BOOKLET BEFORE STARTING WORK OR BEFORE OPERATING EQUIPMENT OR MACHINERY IS COMPULSORY. DO NOT DISPOSE OF WITH ORDINARY TRASH. STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 3 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 4: Safety Rules

    NOTE IF THE SYSTEM NEEDS TO BE STORED PRIOR TO INSTALLATION, STORAGE MUST BE IN A DRY PLACE. NOTE STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 4 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 5: Ups Disposal And Recycling

    RESOURCES AND PREVENT ANY POTENTIAL NEGATIVE EFFECTS ON HUMAN HEALTH AND THE ENVIRONMENT, WHICH COULD OTHERWISE ARISE FROM INAPPROPRIATE WASTE HANDLING STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 5 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 6: Certification Standards

    IEC 61000-4-5 (Surge): level 2 (Line-Line) level 3(Line-Earth). • IEC 61000-4-6 (CS): level 3. • IEC 61000-4-8 (Power Frequency Magnetic Field Immunity): level 4. STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 6 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 7: Introduction

    HDPE Polyvinyl chloride Low-density polyethylene LDPE Polypropylene Polystyrene FOLLOW ALL LOCAL REGULATIONS FOR THE DISPOSAL OF PACKING MATERIALS NOTE STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 7 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 8: General Characteristics

    — 3-1 ISO TX rear panel view Item Load output connection Input (to UPS output) Temperature signal port — STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 8 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 9: Installation

    PACKING MATERIALS MUST BE DISPOSED OF IN COMPLIANCE WITH ALL LOCAL REGULATIONS CONCERNING WASTE. RECYCLING SYMBOLS ARE PRINTED ON THE PACKING MATERIALS TO FACILITATE SORTING. STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 9 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 10: Installing In The Rack Position

    Step 1: Install mounting ears to the side mounting holes of the Transformer box using the — 4.4.1-1 screws provided, mounting ears should face forward. Step 1 — 4.4.1-1 STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 10 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 11 Step 2 — 4.4.2-1 Step 2: Place MBS(optional), UPS, EBM, and ISO TX on tower feet assembly. — 4.4.2-2 STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 11 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 12 Step 4: Fix wires on terminal block as needed (terminal wiring details in the following paragraphs), through the cable gland, and assemble the terminal cover back on unit. — 4.4.3-3 STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 12 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 13 (L1 – L2) of UPS is 240V. b) if the output voltage (L1 – L2) of UPS is 208V. STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 13 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 14 TX and dry contact terminal of UPS. Step 8: Connect the input cables of UPS according to related user manual. STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 14 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 15 ISO TX Output [Load L1, Load L2, PE] 3 x 10AWG 3 x 8AWG ISO TX Jumper 1 x 10AWG 1 x 8AWG STATUS: SECURITY LEVEL: DOCUMENT ID: REV: LANG: PAGE: 15 / 18 Approved Public 4NWD005663 © Copyright 2022 ABB. All rights reserved.
  • Page 16 72.5 kg / 159.8 lbs 696 x 131 x 438mm / 27.4 x 5.25 x 17.24 inches Electrical ISO TX 6K / ISO TX 10K Rated input voltage 208 Vac / 240 Vac Rated output voltage 115Vac / 208Vac / 240 Vac...
  • Page 18 — ABB Switzerland Ltd. Via Luserte Sud 9 6572 Quartino Switzerland www.abb.com/ups © Copyright 2022 ABB. All rights reserved. Specifications subject to change without notice.

This manual is also suitable for:

Iso tx 10k